For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 56.06 — Testing of assemblies

Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 56.06

Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/c3ade0e5-edf4-4608-8013-edbe7239807a

§ 56.06: Testing of assemblies.

All BPAT backflow assembly testing and repair activities including reports are to be completed at time of testing by the BPAT utilizing the city's reporting process. Re-testing activities are required for failed assembly issues with extension timelines for corrective actions approved by the city. Any late BPAT backflow assembly testing reports, or repair activities not addressed are subject to fees and penalties as allowed for by the Code of Ordinances of the City of Carrollton. (A) All backflow prevention assemblies shall be inspected and tested or caused to be inspected and tested in compliance with city and TCEQ regulations in each of the following circumstances: (1) Immediately after installations; (2) Whenever the assembly is moved; (3) A minimum of once a year (excluding non-health residential irrigation devices); (4) Premises that have been vacated and unoccupied for one year, prior to re-occupancy; (5) Immediately after repairs; and (6) There is reason to believe the assembly is not working properly. (B) All assembly testing shall be performed by a BPAT. (C) Duly authorized employees of the city bearing proper credentials and identification are entitled to enter any public or private property at any reasonable time for the purpose of enforcing this chapter. Persons and occupants of premises which are provided with water service by the city, either directly or indirectly, shall allow the city or its representatives ready access at all reasonable times to all parts of the premises for the purposes of inspection, testing, records examination, or in the performance of any of their duties. Where persons or occupants of premises have security measures in force which would require proper identification and clearance before entry into their premises, the persons and occupants of the premises shall make necessary arrangements with their security guards so that upon presentation of suitable identification, personnel from the city will be permitted to enter, without delay, for the purposes of performing their specific responsibilities. (D) The city is not liable for any damage to a backflow prevention assembly which may occur during installation, testing, or repair. (E) A customer service inspection may be conducted at any premises located in the city which is served by the public water supply, or which provides water to the public. Upon determination that the premises falls under the provisions of this chapter and requires a backflow prevention assembly, a notice to abate the condition or to install the proper backflow prevention assembly shall be issued. (F) It is the responsibility of the person who owns or controls the premises to have all assemblies tested in accordance with this chapter. Assemblies may be required to be tested more frequently if the city deems it necessary. (G) All results from assembly testing by a BPAT will utilize the city authorized reporting requirements.

( Ordinance 4293 adopted 12/2/2025 )

Ask a question about Carrollton law

Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.