§ 56.19 — Compliance for landscape irrigation systems
Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 56.19
Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/b901c08d-fddb-40f2-a1cb-2c5d133864a3
§ 56.19: Compliance for landscape irrigation systems.
Installation requirements must comply with the current city plumbing code and TCEQ requirements for system installation and appropriate backflow prevention assembly requirements in this chapter. Interconnections of the potable water supply with an alternate water source is prohibited unless appropriate backflow protection is installed. Approved backflow protection assemblies must be installed for any landscape irrigation systems and testing requirements for the backflow assembly shall apply. (A) Water contained within the piping of an irrigation system is deemed to be non-potable. No drinking or domestic water usage, such as, but not limited to, filling swimming pools or decorative fountains, shall be connected to an irrigation system. If a hose bib (an outdoor water faucet that has hose threads on the spout) is connected to an irrigation system for the purpose of providing supplemental water to an area, the hose bib must be installed using a quick coupler key on a quick coupler installed in a covered purple valve box and the hose bib and any hoses connected to the bib must be labeled "non-potable, not safe for drinking." An isolation valve must be installed upstream of a quick coupler connecting a hose bib to an irrigation system. (B) A city permit is required to construct, install, alter, extend, or repair a landscape irrigation system. Homeowners conducting said work on their property are still required to obtain a city-issued permit at no cost but must still abide by TCEQ and city requirements as they pertain to landscape irrigation systems. (C) Landscape irrigators working in the city must be licensed and meet all registration requirements to perform services such as design, installation, repair, and connection of an irrigation system to the public water supply. All other landscape irrigation system related activities that involve irrigation technicians, and irrigation inspectors, shall also meet city registration and TCEQ licenses requirements. (D) An irrigator shall ensure the backflow prevention assembly is tested prior to being placed in service, or after any repair to the assembly, and the test results provided to the city and the irrigation system's owner or owner's representative following testing of the backflow prevention assembly. (E) Landscape irrigation systems that are deemed health hazards shall also be tested annually or more frequently as may be required by the city. (F) Atmospheric vacuum breakers (AVB) are not permitted to be installed on landscape irrigation systems. Existing AVB's are required to be retrofitted with a newly approved backflow prevention assembly when the landscape irrigation system undergoes repair and/or alteration. (G) All newly installed backflow prevention assemblies for landscape irrigation systems deemed non-health hazards, are required to be tested and certified by a TCEQ-licensed and city-registered backflow prevention assembly tester upon installation (H) Design and Installation: Before any chemical is added to an irrigation system connected to any potable water supply, the irrigation system must be connected through a reduced pressure principal backflow prevention assembly or air gap. (1) Connection of more than one water source to an irrigation system presents the potential for contamination of the potable water supply if backflow occurs. Therefore, connection of any additional water source to an irrigation system that is connected to the potable water supply can only be done if the irrigation system is connected to the potable water supply through a RP or an air gap. (2) Irrigation system components with chemical additives induced by aspiration, injection, or emission system connected to any potable water supply must be connected through a RP. (3) If an irrigation system is designed or installed on a property that is served by an on-site sewage facility (OSSF), as defined in 30 Tex. Admin. Code Chapter 285 relating to On-Site Sewage Facilities. (4) All irrigation piping and valves must meet the separation distances from the On-Site Sewage Facilities system as required for a private water line under 30 Tex. Admin. Code § 285.91(10), Relating to Minimum Required Separation Distances for On-Site Sewage Facilities. (5) Any water from the irrigation system that is applied to the surface of the area utilized by the On-Site Sewage Facility system must be controlled on a separate irrigation zone or zones so as to allow complete control of any irrigation to that area so that there will not be excess water that would prevent the on-site sewage facilities system from operating effectively. (6) An accurate irrigation design must be developed for each new system before installation begins and must be on-site during construction. (7) The design should consider factors like effluent characteristics and site-specific conditions. (8) Drip irrigation systems require a design by a professional engineer or professional sanitarian and can only be installed by a TCEQ licensed OSSF installer class II. (9) All system components must be installed according to the approved design and regulations. (I) Graywater and alternative on-site water: (1) If using graywater or alternative on-site water, a designated area for future OSSF expansion must be set aside. (2) Graywater or alternative on-site water should not be applied to the surface of a reduced OSSF disposal field. (3) Physical connection between the graywater or combined reuse system and the OSSF is prohibited. (4) Three days of graywater storage are required when using a graywater or combined reuse system with a reduced OSSF. (5) Upon property transfer, buyers must be notified of the OSSF limitations and their responsibilities by the seller and/or their agent. (6) Tanks used for water storage should be clearly labeled, have restricted access, and not create vector habitats.
( Ordinance 4293 adopted 12/2/2025 )
Ask a question about Carrollton law
Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.
