§ 56.14 — Fire suppression systems

Code of Ordinances, City of Carrollton, Texas (Includes legislation through Ord. No. 4326 adopted September 1, 2026) · Carrollton City Code § 56.14

Corpus is an independent public-information project, not the official City of Carrollton website. Stable reference: corpuslaw.us/code/6eed2f11-5d82-4280-8487-0e569243091f

§ 56.14: Fire suppression systems.

The city potable water supplies to all fire protection systems that are normally under pressure, including but not limited to standpipes and automatic sprinkler systems and shall be protected from cross-connections resulting from backpressure or backsiphonage by a city-approved backflow prevention assembly. (A) All new installations of fire suppression systems which utilize the city's potable water supply shall have installed approved backflow prevention devices (RPDA or DCDA) according to the degree of hazard and metering requirements to capture unauthorized water use. (B) An approved DCDA or RPDA shall be the minimum protection for fire sprinkler systems using piping material that is not approved for potable water use and/or that does not provide for periodic flow-through during each 24-hour period, unless a variance has been issued in writing from the city. A RPDA must be installed if any solution other than the potable water can be introduced into the sprinkler system. (1) It is the responsibility of all property owners and persons in charge of any premises to abide by the requirements of this chapter. In the event of any changes to the plumbing system, it is the responsibility of the property owner to notify the city. All costs associated with this chapter and the purchase, installation, testing and repair of DCDA or RPDA devices is the responsibility of the property owner and persons in charge of any premises. (2) Upon the approved installation of the DCDA or RPDA device, a cross-connection test report completed by a city registered and licensed BPAT Fireline tester must be sent to the attention of the city and include the information required by this chapter. (C) Fire department connection: Where fire protection systems supplied by a potable water system include a fire department (siamese) connection located less than 100 feet from a non-potable water source that is capable of being used by the fire department as a secondary water supply, the potable water supply shall be protected by one of the following: (1) Fire department connection (FDC) shall be installed and connected in a manner that backflow will not occur under firefighting activities creating a cross-connection to the potable water supply. On existing FDC installations where there is only a check valve in place, required inspection activities following the National Fire Protection Association (NFPA) requirements to confirm the check valve on the FDC is operational, if it is not, the city shall require the appropriate backflow prevention assembly to be installed to protect the water main from the FDC. (2) Reduced pressure principle detector backflow prevention assembly: RPDA fire protection backflow prevention assembly shall be used for non-potable water sources including fire department vehicles carrying water of questionable quality or water that is treated with antifreeze, corrosion inhibitors, or extinguishing agents. (3) Chemicals: Where antifreeze, corrosion inhibitors, or other chemicals are added to a fire protection system supplied by a potable water supply, the potable water system shall be protected by one of the following: (a) Reduced pressure principle backflow prevention assembly (RP). (b) Reduced pressure detector backflow prevention assembly. (D) Connections to automatic fire sprinkler systems and standpipe systems: (1) The potable water supply to automatic fire sprinkler and standpipe systems shall be protected against backflow by a double check backflow prevention assembly, a double check fire protection backflow prevention assembly or a reduced pressure principle fire protection backflow prevention assembly. (E) Fire hydrant lines: A backflow prevention assembly is not required on a public fire hydrant line provided the water line is installed in compliance with city water main American Water Works Association (AWWA) standards. (1) Potable water lines serving on-site private fire hydrants require installation of a double check (DC) or reduced pressure (RP) assembly is required on both ends of a private water main that is connected to the public water service at two or more locations. (2) This requirement will apply even if the private water main is installed only to serve a fire sprinkler, standpipe, or hydrant system. (F) Location of backflow prevention assemblies for fire protection systems backflow prevention assemblies shall be located as close as practicable to the point of water service delivery (typically the water meter). (1) Point of service delivery means the terminal end of a service connection from the public water system. If a meter is installed at the end of the service connection, then the point of service delivery shall mean the downstream end (i.e., customer's side) of the meter. If an unmetered connection exists, then the point of service delivery shall mean at the point of demarcation between the public right-of-way or easements and private property. (2) The term service connection shall mean the terminal end of a service connection from the public potable water system, (i.e., where the water purveyor may lose jurisdiction and sanitary control of the water at its point of delivery to the consumer's water system). (3) If a water meter is installed at the end of the service connection, then the service connection shall mean the downstream end of the water meter. Close as practicable is the point nearest the service delivery where the assembly can be installed. (4) Where the assembly installation location may interfere with obstacles such as driveways and sidewalks, then close as practicable is the nearest point after the obstacle, but in no way beyond the first tap. (5) Assemblies must NOT be located in traffic visibility triangles or where utility devices are prohibited by the zoning ordinance. (6) Locating an assembly behind the front yard zoning setback line, just around a building corner, or otherwise in coordination with a building design element, is typically acceptable without special justification provided the reason for the chosen location is readily apparent on the plan. (G) Existing fire protection system retrofit: The city may require retrofitting of an existing fire protection systems backflow protection where inadequate backflow protection is in place and/or address incidents of unaccounted for water loss: (1) Retrofitted or remodeled fire protection systems shall have an approved backflow prevention assembly installed as close as practicable to the point of water service delivery when the hydraulic calculations of the sprinkler system demand that a new and/or larger service connection to the public water supply system is required. (2) When retrofitting or remodeling existing systems, a thorough hydraulic analysis, including revised calculations and new fire flow data, is necessary to accommodate the backflow prevention device and any associated friction loss. (3) All required plan review and permitting is required prior to retrofitting activities taking place. (H) Fire line backflow preventers shall meet the approval requirements and be listed by the USC-FCCCHR and/or city authorization on fire lines prior to fire line permit issuance. (I) Testing and maintenance: (1) Backflow prevention assemblies must be tested upon installation and at regular intervals as specified in this chapter. (2) The owner of the backflow prevention assembly is responsible for ensuring timely testing. (3) A city registered and TCEQ Licensed Fireline BPAT is required to perform tests and repairs. (J) System modifications: (1) Test valves. (a) New water-based fire suppression systems must include test valves downstream of the backflow preventer. (b) These valves should be specific types (angle or globe) with defined thread specifications and quantities based on the system design flow. (2) Responsibility. The property owner is responsible for the maintenance and operation of the backflow prevention devices and for ensuring that required fire protection measures are in place during testing and restoration which can include the city requirements for a fire watch.

( Ordinance 4293 adopted 12/2/2025 )

Ask a question about Carrollton law

Corpus searches the Carrollton sections it holds and shows the ones that match, with their citations. Free, no sign-in.