For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 5.3.6 — Industrial Uses

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 5, § 5.3.6

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/d141dda4-6a1b-47b1-8224-1bd412584b59

5.3.6 - Industrial Uses.

A. Craft Alcohol Production. In the MD, MR, and SC zoning districts: 1. On-premise consumption or retail sales shall be required to operate a craft alcohol production establishment. 2. Areas used for production, bottling, packaging, storing, and other manufacturing related activities shall not exceed 10,000 square feet of gross floor area per lot. Additional square footage shall require specific use permit approval pursuant to Subsection 2.5.2: Specific Use Permit (SUP). 3. The storage of raw and/or spent materials shall be kept in a fully enclosed structure, building, or container. 4. The establishment shall operate in full compliance with all rules and regulations of the Texas Alcoholic Beverage Commission. B. Food Processing, Less than 2,500 Square Feet. 1. MN, MD, MR, and SC Zoning Districts. Only on-premises sales shall be allowed. Distribution, warehousing, or wholesaling activities are prohibited. 2. All Zoning Districts. If the proposed use is within 200 feet of a residential zoning district, approval is subject to a specific use permit pursuant to Subsection 2.5.2: Specific Use Permit (SUP). C. Food Processing, More than 2,500 Square Feet. 1. MN, MD, MR, and SC Zoning Districts. Only on-premises sales shall be allowed. Distribution, warehousing, or wholesaling activities are prohibited. 2. All Zoning Districts. If the proposed use is within 200 feet of a residential zoning district, and greater than 5,000 square feet per lot, then approval of a specific use permit shall be required pursuant to Subsection 2.5.2: Specific Use Permit (SUP). D. Manufacturing, Artisan. In the MN and MD zoning districts: 1. Artisan manufacturing uses shall be limited to 10,000 square feet per lot. 2. If within 200 feet of a residential zoning district or residential use, artisan manufacturing uses shall be limited to 5,000 square feet per lot, unless a specific use permit is approved pursuant to Subsection 2.5.2: Specific Use Permit (SUP), and permits the use to exceed 5,000 square feet per lot. 3. All activities shall occur entirely within an enclosed structure. E. Manufacturing, Low-Impact. 1. In the MD Zoning District, uses are limited to a maximum of 10,000 square feet of gross floor area per lot. 2. In the MR, SC, and HC Zoning Districts, uses with more than 10,000 square feet of gross floor area per lot shall require a Specific Use Permit pursuant to Subsection 2.5.2: Specific Use Permit (SUP). 3. In the MD, MR, SC, HC, and GO Zoning Districts, all activities shall occur entirely within an enclosed structure. F. Outdoor Storage (as a Primary Use). 1. Materials shall not be stored in areas intended for vehicular or pedestrian circulation. 2. Materials stored outdoor shall be setback at least five feet from all property lines. 3. Outdoor storage shall be opaquely screened from all rights-of-way, residential zoning districts, and residential uses, and shall comply with standards in Subsection 7.7.8: Walls, Fences, and Screening. G. Self-Service Storage. 1. Building Materials. a. Except for fenestrations, as noted in subsection (1)(b) below, each elevation shall be constructed of 100 percent masonry, stone, architectural concrete block with integrated color (split-face CMU), stucco, or concrete tilt-wall (colored or stamped). b. The materials in subsection (1)(a) above shall not apply to fenestrations such as doors, windows, glass, and entryway treatments. c. Glass shall not account for more than 70 percent of the exterior wall area. 2. Doors. Overhead bay doors and/or storage unit doors shall not be visible from adjacent properties or public right-of-way. 3. Fencing and Buffers. a. Fencing materials shall be limited to masonry and wrought iron and shall comply with Subsection 7.7.8: Walls, Fences, and Screening. b. Landscape buffers shall be provided in accordance with Section 7.7.6: Compatibility Landscape Buffer Requirements. 4. Other Activities. a. Rental of storage units, rental of storage space for recreational vehicles (RV) and boats, and the sale of moving related items are allowed uses. b. No other land use or business activity within storage units is allowed. c. The rental of moving trucks and moving related equipment shall constitute an Equipment Sales and Rental use. d. The sale and leasing of recreational vehicles (RVs) and boats shall constitute an Automotive Sales and Leasing use. 5. Outdoor Storage. Outdoor storage of recreational vehicles (RVs) and boats is prohibited, except: a. Within the MN, MD, MR, SC, HC, and GO Zoning Districts recreational vehicles (RVs) and boats shall be maintained entirely within an enclosed structure or shall be opaquely screened from all rights-of-way, residential zoning districts, and residential uses with a minimum eight (8) foot tall wall or fence of masonry, elevated and sealed wood or a combination of such materials. b. Within the LI and HI Zoning Districts recreational vehicles (RVs) and boats shall be maintained entirely within an enclosed structure or shall be opaquely screened from all rights-of-way, residential zoning districts, and residential uses, and shall comply with standards in Subsection 7.7.8: Walls, Fences, and Screening. H. Warehouse and Wholesale Facility. In the MR and SC zoning districts, uses shall be limited to a maximum of 55,000 square feet of gross floor area per lot. I. Data Center, Modular. 1. Modular structures, on-site electrical equipment, and any associated outdoor storage shall be opaquely screened from view of the public right-of-way and any adjacent residential use or zoning district utilizing any combination of the allowed fence and wall materials for industrial uses identified in Subsection 7.7.8. If non-opaque fence or wall materials are proposed, evergreen plant materials must be provided at appropriate intervals to make the screening opaque at planting. 2. Modular structures, on-site electrical equipment, and any associated outdoor storage area shall be setback no less than 100 feet from an adjacent residential zoning district or an existing residential use, measured from the property line. 3. At least two elements from Table 7.E: Landscape Area Point System, Section A Right-of-Way Elements shall be provided along all public rights-of-way, regardless of whether front parking or drive-aisles are proposed. 4. An environmental noise and vibration assessment is required with the initial application, prepared by a professional qualified in the area of noise mitigation, detailing how the proposed use complies with the maximum permissible noise levels described in number 5 below. The environmental noise and vibration assessment must: i. Identify operation noise impacts; ii. Provide documentation establishing the ambient noise level prior to installing any modular structures and on-site electrical equipment; iii. Detail how the impacts will be mitigated. In determining noise mitigation, specific site characteristics shall be considered, including but not limited to the following: a. Nature and proximity of adjacent development, location and type; b. Seasonal and prevailing weather patterns, including wind directions; c. Vegetative cover on or adjacent to the site; and d. Topography. iv. The applicant shall be responsible for verifying compliance with the environmental noise and vibration assessment noise mitigation measures after the installation. 5. Data center operations, including on-site electrical equipment, shall not cause any noise measuring more than 60 dba on the A-weighting utilizing properly calibrated sound measuring instrumentation measured at the property line, or shall not cause an increase in the ambient noise level in the area more than 3 dba. 6. On-site Electric Substations shall comply with Section 7.13.7 Electric Substation Design of the Denton Development Code. J. Data Center, Warehouse. 1. In the MR and SC Zoning Districts, the use shall be limited to a maximum of 55,000 square feet of gross floor area per lot. 2. Buildings shall comply with the design standards established in Section 7.10.5: Nonresidential and Mixed-Use Building Site and Building Design. 3. On-site electrical equipment and any associated outdoor storage shall be opaquely screened from view of the public right-of-way and any adjacent residential use or zoning district utilizing any combination of the allowed fence and wall materials for industrial uses identified in Subsection 7.7.8. If non-opaque fence or wall materials are proposed, evergreen plant materials must be provided at appropriate intervals to make the screening opaque at planting. 4. On-site electrical equipment, and any associated outdoor storage area shall be setback no less than 100 feet from an adjacent residential zoning district or an existing residential use, measured from the property line. 5. An environmental noise and vibration assessment is required with the initial application, prepared by a professional qualified in the area of noise mitigation, detailing how the proposed use complies with the maximum permissible noise levels described in number 6 below. The environmental noise and vibration assessment must: i. Identify operation noise impacts; ii. Provide documentation establishing the ambient noise level prior to installing any modular structures and on-site electrical equipment; iii. Detail how the impacts will be mitigated. In determining noise mitigation, specific site characteristics shall be considered, including but not limited to the following: a. Nature and proximity of adjacent development, location and type; b. Seasonal and prevailing weather patterns, including wind directions; c. Vegetative cover on or adjacent to the site; and d. Topography. iv. The applicant shall be responsible for verifying compliance with the environmental noise and vibration assessment noise mitigation measures after the installation. 6. Data center operations, including on-site electrical equipment, shall not cause any noise measuring more than 60 dba on the A-weighting utilizing properly calibrated sound measuring instrumentation measured at the property line, or shall not cause an increase in the ambient noise level in the area more than 3 dba. 7. On-site Electric Substations shall comply with Section 7.13.7 Electric Substation Design of the Denton Development Code.

(Ord. No. DCA19-0025a, § 2(Exh. A), 2-4-2020; Ord. No. DCA22-0003a, § 2(Exh. A), 9-20-2022; Ord. No. DCA22-0008a, § 2(Exh. A), 3-7-2023)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.