For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.3.2 — Lot Planning

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 8, § 8.3.2

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/65c036d5-97eb-4f22-926f-b4a9c2712fc1

8.3.2 - Lot Planning.

A. General. The size, shape, and orientation of lots shall be appropriate to the location of the proposed subdivision and to the type of development contemplated. The following lot design standards shall apply to all subdivisions: 1. All lots created through the subdivision process shall be developable and conform to the minimum zoning, development, and floodplain standards stated in this DDC. No subdivision shall create lots that prohibit development due to configuration of the lots, steepness of terrain, location of watercourses or floodplain, natural physical conditions, or other existing conditions, except when in conflict with ESA regulations. 2. The minimum area and dimensions of all lots shall conform to the requirements of Subchapter 3: Zoning Districts, and Subchapter 6: Development Standards, relating to the zoning district in which the lot is located. This subsection does not apply to planned developments. Modifications may be granted pursuant to Subsection 8.3.2D of this subsection. 3. Side lot lines shall be at right angles or radial to street lines, except where other terrain makes such design impractical. 4. Double frontage lots may be allowed; however, access shall be in accordance with the requirements of the Denton Development Code, Fire Code, and Transportation Criteria Manual. 5. Flag lots and other irregularly shaped lots are discouraged. 6. Corner lots may be required to be wider than interior lots to facilitate conformance with setback and driveway spacing requirements. 7. The city, county, school district, or other taxing agency boundary shall not divide a lot except in conformance with this DDC. 8. Each residential lot shall have a minimum of 15 feet of frontage along an existing or proposed public street except as provided in paragraph 8.3.2C.2. 9. Each mixed-use and nonresidential lot shall have a minimum 20 feet of frontage along an existing or proposed public street. 10. Refer to Section 7.10.3C: Open Space Requirements, for common open space requirements for single-family detached dwelling, duplex, townhome, triplex, or fourplex developments. 11. Full access to a site across a property must occur through a zoning district that allows the proposed use. Emergency only access is exempt from this requirement. Subdividing a lot and dedicating a public right-of-way to access the site does not exclude this requirement. B. Drainage. Lots shall be designed and located to provide positive drainage away from all buildings and shall comply with the standards in Section 7.5: Drainage. C. Access. 1. Generally. a. Each lot shall be provided with adequate access to an existing or proposed public street. b. Development adjacent to existing public streets shall include the required improvements in accordance with the city's perimeter street policy and in accordance with TLGC, § 212.904. c. At least two full points of vehicular access into the proposed development shall be provided for the following: i. Residential Uses (as listed in Table 5.2-A). a. New construction with 30 dwelling units or more. b. Expansions or additional phases to an existing development resulting in a cumulative increase of 30 dwelling units or more. c. Properties within the MD Zoning District are exempt from this requirement. d. Development sites two (2) acres or less, with a parking structure are exempt from this requirement. ii. Nonresidential uses. a. Developments on lots 20,000 square feet or larger. b. Re-platting resulting with developments on lots 20,000 square feet or larger. c. Properties within the MD Zoning District are exempt from this requirement. d. Development sites two (2) acres or less, with a parking structure are exempt from this requirement. d. The requirement of Subsection 8.3.2C.1.c.ii may be waived when it is shown to the satisfaction of the City Engineer that two points of vehicular access are deemed unattainable on the basis of: topography; the presence of natural drainage features or Environmentally Sensitive Areas; adjacent site improvements making it unattainable to provide second access; or vehicular or pedestrian safety factors. e. All developments must meet Fire Code access and remoteness requirements and the Transportation Design Criteria Manual driveway spacing requirements. f. Full access (ingress and egress) shall be credited for providing access into the development. 2. Single-Family Residential Private Drive. a. Up to three single-family detached or townhome residential dwelling units may access a public road by means of a flag drive within a private access easement as provided in the Transportation Design Criteria Manual. b. Each residential lot shall have a minimum of 15 feet of frontage on the private access easement. Figure 8.3-A: Single Family Residential Private Drive [image omitted; see the official code] 3. Mixed-Use and Nonresidential Drives. a. Lots within a subdivision or addition that is surrounded by developed property making it unfeasible to provide street connectivity, do not have to abut a public street if such lots have access to a public street by a public access and fire lane easement approved by the city. b. Such easement shall be at least 24 feet wide and constructed, marked, and maintained to meet the standards for parking lots as contained in the Transportation Design Criteria Manual and for fire lanes as contained in the Fire Code. c. The stacking requirements for public streets shall apply to the public access and fire lane easement at the point where it intersects with a public street. d. In addition, the public access and fire lane easement shall be considered a driveway or curb cut access to the public street for all such lots. e. Each nonresidential lot shall have a minimum 20 feet of frontage on the public access and fire lane easement. 4. Drilling and Production Site Access. Truck traffic related to gas well drilling and production shall not be allowed to use a plat's neighborhood streets to access a gas well drilling and production site. In addition, no plat shall be allowed to eliminate or alter an access road or easement depicted on a gas well development plat or gas well development site plan, unless written consent of the gas well operator is obtained and a separate access road or easement on the plat is provided for access to a drilling and production site. D. Common Area and Facilities. Such areas shall be noted on the plat and the association's covenants shall be filed with the county pursuant to Subsection 8.3.6J. Alternatively, other arrangements for permanent maintenance of these areas and facilities may be approved by the decision-making body. E. Flag Lots. 1. Notwithstanding any other provision of this DDC, the width of the flagpole portion of a flag-shaped lot shall be no less than: a. Thirty feet when both public water and sewer systems are to serve such a residential lot. b. Forty feet when both public water and sewer systems are to serve such a commercial or industrial lot. c. Twenty-four feet when only a public water or a public sewer system is to serve such a lot. d. Twenty-four feet when the lot will not be served by a public water or public sewer system. 2. The flagpole portion of the lot shall be ignored in measuring lot width. 3. The length of the flag pole portion of the lot shall not exceed 300 feet and shall comply with all other standards and measurements of this DDC and other regulating agencies. 4. Flag lots where the length of the flag pole portion exceeds 150 feet shall provide a permanent turn-a-round approved by the City Engineer and the Denton Fire Department.

(Ord. No. DCA22-0007a, § 2(Exh. A), 12-6-2022)

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.