For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.4.11 — Adequate Sewer System

Code of Ordinances, City of Denton, Texas (Supp. No. 37, Update 1: codified through Ordinance No. 26-296 adopted March 24, 2026) · Denton Development Code subch. 8, § 8.4.11

Corpus is an independent public-information project, not the official City of Denton website. Stable reference: corpuslaw.us/code/6d77512d-06ea-47af-9618-77e6b3681f3c

8.4.11 - Adequate Sewer System.

A. Generally. 1. No preliminary or final plat application shall be approved unless the applicant demonstrates that there will be an adequate sanitary sewer system to serve the subdivision concurrent with development. 2. The applicant shall demonstrate that the sanitary sewer system serving the development will be adequate at the time of preliminary plat approval for development within the city limits, or at the time of final plat approval for developments within the city's extraterritorial jurisdiction. 3. Where a development plan or phased preliminary plat is proposed, the applicant shall demonstrate that each phase of the development shall be served by an adequate sanitary sewer system under this standard. 4. The approach main shall be extended to serve the entire development subject to a development plan or phased preliminary plat prior to the time of final plat approval for the second phase of the development plan or phased preliminary plat, unless the extension is part of a funded capital improvement project that the city has initiated consistent with its adopted Capital Improvement Plan for wastewater facilities. 5. Adequacy of treatment facilities cannot be demonstrated by reliance upon package treatment plants. B. Criteria for Adequate Facilities. The sanitary sewer system serving the development shall be deemed adequate when in conformance with Section 7.6: Water and Wastewater, and one the following options, as applicable: 1. City Facilities Not Used. a. Where the city's sanitary sewer system is not to be used, the applicant shall provide assurance that the entity collecting the sewage holds a certificate of convenience and necessity for the land to be subdivided, that collection systems are adequate to accommodate sewage flows from the development and that the treatment system to be used has adequate capacity in accordance with the standards in Section 7.6: Water and Wastewater. b. The applicant shall provide assurances that sanitary sewer mains will be extended to serve the subdivision prior to the time of final plat approval for the second phase of a development plan, or phased preliminary plat. 2. City Facilities are Used. a. Where city collection mains are to be used for collecting sewage, and there is an existing collection main with adequate capacity to serve the development within one mile of the boundary of the proposed subdivision, the applicant may agree to extend one or more existing collection mains to the subdivision of a size adequate to serve the development, at his expense, including the cost to construct all necessary lift stations and force mains, in accordance with standard city participation policies. b. The city reserves the right to require oversizing of the line in accordance with standard City of Denton oversize policies. This requirement does not apply where the approach main is already a component of a funded capital improvement project that the city has initiated, consistent with its adopted Capital Improvement Plan for wastewater facilities.

Ask a question about Denton law

Corpus searches the Denton sections it holds and shows the ones that match, with their citations. Free, no sign-in.