§ 3.86 — Existing Drainageways - Development Criteria
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Development Code § 3.86
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/ee011cb6-97d7-4b23-8626-0024ad4676fa
§ 3.86: Existing Drainageways - Development Criteria.
(A) Purpose. The City acknowledges the wide diversity of existing creeks and drainageways throughout the City and states its intention that overall drainage patterns and features shall be disrupted as little as possible in the process of development, provided that a development must provide adequate drainage through a stable, easily maintainable manner. (B) Floodplain Development Requirements. All development proposed adjacent to or within the 100-year floodplain shall conform with the City’s Flood Damage Prevention Ordinance (Article VII of Chapter 31 of the City Code). (C) Designated on Plat. Any dedications and easements required by this Chapter 3 shall be designated on the Preliminary Plat and Final Plat. (1) Final Plat Inscription. Every Final Plat of a subdivision which contains a drainageway as regulated by this Chapter 3 shall contain special language as set forth in the City’s Technical Standards Manual, as amended. (2) Notice of Inscription to Grantee. In addition, the developer shall include with or in the deed of each lot of the subdivision which abuts or contains a drainageway, a notice of the foregoing language sufficient to inform the grantee of the deed of the requirement contained within the language. (D) Creeks and Natural Drainageways. The following provisions shall apply to all proposed development in relation to creeks. (1) All creeks that have designated floodplains and Flood Insurance Study (F.I.S.) floodways, and any other natural drainage course, as identified by the most current Flood Insurance Rate Maps (FIRM) or by the Director of Engineering, may be left in a natural state, if so approved by the Director of Engineering. (a) In order for the Director of Engineering to approve a creek to be left in its natural state, the natural channel along with the encompassing drainage easement shall be of sufficient width and depth to carry the 100-year storm, plus one foot of freeboard and ten-foot accessway on both sides of the channel. Disturbance of a natural channel is prohibited except that prior to acceptance by the City, the developer shall perform general maintenance such as clearing underbrush, debris dam removal, litter pick-up, and the removal of other undesirable items, as directed by the Director of Engineering. (b) In these cases, the entire 100-year floodplain shall be platted out separately as a drainage easement, and the developer shall provide a means of acceptable access for city stormwater personnel. An erosion hazard setback (per the Technical Standards Manual) may also be included in the drainage easement dedication. The drainage easement shall be dedicated on the Final Plat as a separate lot to be owned and maintained by a Homeowners’ or Property Owners’ Association (as applicable for residential or nonresidential). At no time shall any portion of the 100-year floodplain exist or be within any single-family or two-family residential lot unless the lot is not within a Homeowners or Property Owners Association or a subdivision containing four or more lots, unless it is contained in a subdivision consisting of fewer than four lots. A minimum ten-foot wide accessway shall be provided along each side of the drainageway and included in the drainage easement with a traverse slope not to exceed ten percent, all in accordance with the Technical Standards Manual. i. Such access shall be subject to review and approval by the Director of Engineering, and streets or alleys may be required between dedicated properties and adjacent development. ii. Other undeveloped floodplain may also be dedicated as a drainage easement, pursuant to Subsection (b) above, at the time of platting. (2) Responsibility for drainage maintenance shall be set forth in the drainage easement. (3) So as to meet the stability and maintenance provisions in Subsection A above, the City may require improvements to creek or creek banks, in accordance with the Technical Standards, before issuance of a Letter of Final Acceptance in accordance with Section 3.111 of this Chapter 3. (4) In order to negate or mitigate the need to obtain flood insurance, all portions of residential lots shall be removed from designated floodplains in accordance with the Technical Standards Manual. In all cases, the developer shall adhere to the requirements set forth in the City Code regarding flood damage prevention, and shall furnish engineering plans prepared by a professional engineer who is licensed in the State of Texas to the Director of Engineering for review and approval. (5) The following provisions shall apply to all proposed development within the Rowlett and Spring Creek 100-year floodplains, as more particularly described on the Albert H. Halff Associates, Inc., November 1988, Rowlett and Spring Creek Flood Plain Management Study: (a) Base flood elevations (BFE) for the 100-year flood event that reflect ultimate development land use throughout the watershed shall be used for design and planning of floodplain development. (b) Development within the floodplain shall be permitted only if it can be demonstrated that there will be no rise in the base flood elevation. (c) Fill volumes shall be balanced (+/- 15%) by excavation volumes to preserve overall valley storage within the floodplain. Areas excavated shall be landscaped to restore a natural cover. (d) The bed and banks of Rowlett and Spring Creeks shall be left in a natural state to control erosive velocities, prevent excessive downstream discharges, and preserve the natural effect of the stream. Exceptions are permitted for major bridge crossings, public welfare, and safety. (e) Increases to existing average velocities shall be allowed to a maximum average velocity of no greater than six feet per second. (f) Significant stands of trees and other environmental features within the floodplain shall be preserved. (6) All lots adjacent to a creek or drainageway shall have minimum finished floor elevations defined on the subdivision plat a minimum of two feet above the FEMA F.I.S. one-hundred-year water surface elevation. Where available, the fully developed watershed water surface elevation shall be used to establish minimum finished floor elevations. (7) Paved stormwater access driveways with removable bollards shall be provided from a public street right-of-way to drainage easements incorporating creeks or drainageways as directed by the Director of Engineering. (E) All development shall comply with Article VII (Flood Damage Prevention) of Chapter 31 of the City Code. It shall be the responsibility of the developer to obtain a Conditional Letter of Map Revision (CLOMR) issued by the Federal Emergency Management Agency (FEMA) prior to approval of Site Engineering Drawings (and subsequent issuance of a Site Permit) and a Letter of Map Revision (LOMR) prior to issuance of a Letter of Final Acceptance in accordance with Section 3.111 of this Chapter 3. (F) Upon completion and a Letter of Final Acceptance (Section 3.111 of this Chapter 3) being issued for any drainageway channel improvements as set forth within this Section 3.86 of this Division 8, the property owner on whose property the channel improvements lie, or whose property directly abuts such channel improvements, shall be responsible for necessary mowing, irrigation, weeding, litter pick-up, fertilizing, and such other maintenance as is required to maintain a healthy stand of grass or other groundcover. (G) No obstruction to the flow of stormwater runoff shall be permitted. (H) Additional Studies. Upon request by the City, the property owner shall submit additional studies, including but not limited to the following, as deemed appropriate and necessary by the City, as part of the Preliminary Plat (if applicable) or Final Plat submittal requirements. These studies shall be considered during review and approval of the Preliminary or Final Plat, as applicable. (1) Wetland Delineation and Waters of the U.S. Study; (2) Erosion Hazard Setback Study; (3) Storm Drainage Study; (4) Flood Study; and (5) Downstream Assessment Study.
( Ordinance 6773 adopted 5/19/15 ; Ordinance 7055 , sec. 26, adopted 5/7/19 ; Ordinance 7107 , sec. 48, adopted 12/3/19 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.