§ 3.87 — Storm Sewers - General Requirements
Code of Ordinances of the City of Garland, Texas (Garland Code of Ordinances, Home Rule Charter and Garland Development Code current through Ordinance 7697 adopted August 17, 2026 (eCode360 publication GA6318, scraped 2026-11-17)) · Garland Development Code § 3.87
Corpus is an independent public-information project, not the official City of Garland website. Stable reference: corpuslaw.us/code/caf64674-cdc4-4dd9-948d-40b87096f3d5
§ 3.87: Storm Sewers - General Requirements.
(A) Erosion Control. Erosion control shall comply with the City’s Technical Standards, as amended. (B) Requirement. Underground storm sewer systems are required, as defined in the Technical Standards, to prevent excessive stormwater runoff from entering the public street or rights-of-way or private streets. (C) Public underground storm sewer systems shall be contained in the public street right-of-way or within a drainage easement that is in accordance with the City’s Technical Standards Manual. At low points on grade, a concrete-lined positive overflow path shall be provided. The positive overflow path shall be contained in a drainage easement of sufficient width to convey the 100-year storm runoff. (D) Calculation of Runoff. The calculation of stormwater runoff shall comply with the Technical Standards. Stormwater runoff calculations shall be made anticipating a fully developed watershed, prepared and sealed by a professional engineer licensed in Texas, and submitted for review and approval by the Director of Engineering. The Comprehensive Plan, existing land use, and zoning maps shall be used to determine fully developed conditions. The Director of Engineering reserves the right to review the determination of fully developed conditions and may require revisions. (E) Detention. If stormwater runoff from a proposed development exceeds the capacity of the existing downstream system, detention of stormwater runoff in a manner prescribed by Section 3.89 of this Division 8 shall be provided for the excess runoff. Easement and maintenance responsibilities for the detention system shall be inscribed on the Preliminary Plat and Final Plat. (F) Easements. Drainage easements shall be dedicated for public drainage features in accordance with requirements of this GDC. Drainage easements and features shall be included as a portion of buildable (such as habitable structure) lot(s) and not as a separate self-standing lot unless specifically authorized by the Director of Engineering. If a large development-related feature is authorized on a separate lot, a Homeowners’ Association is required to assume maintenance responsibilities for the feature(s). Storm drainage easements shall be located along side property lines, and such easements shall be contained fully on one lot or tract, and shall not be split across the property line between two lots or tracts. (G) Minimum Finished Floor Elevations. The Director of Engineering may require minimum finished floor elevations (FFEs) to provide flood protection on certain lots within a development. The FFEs shall be shown on the Final Plat. These elevations shall incorporate the most current floodplain management criteria or other criteria as necessary to avoid damages. FFEs shall be two feet above the fully developed 100-year water surface elevation where an FFE is associated with a natural major creek or open channel. When an FFE is necessitated by situations other than a natural major creek or open channel, the FFE shall be set by the developer’s engineer and shall be subject to the approval of the City. (H) Off-Site Drainage. When a proposed development requires off-site grading where stormwater runoff has been collected or concentrated, it shall not be allowed to drain onto adjacent property except into existing major creeks, channels, storm sewers or streets unless a notarized letter of permission is obtained from the owner of the property onto which the drainage will drain. The letter shall state that the permission shall bind the owner of the affected property and shall be a covenant running with the land. It shall also refer to the plans for the improvements creating the need for the permission. The letter shall be filed for record with the applicable county. (I) Definitions. Unless a provision explicitly states otherwise, the following terms and phrases, as used in this section, shall have the following meanings: (1) “Amenity pond” means a permanent pool of a pre-determined volume of stormwater kept or maintained purely for aesthetic purposes and that is not designed to provide additional capacity for the temporary storage of stormwater required for detention. (2) “Capacity” means the maximum stormwater rate allowed in any portion of the MS4 that will not result in a surcharge of the system, or, as determined by the managing director, the maximum stormwater rate that can be allowed in any portion of the MS4. (3) “Development” means any manmade change to real property, whether previously improved or unimproved, including, without limitation, filling, grading, paving, the installation of infrastructure such as water lines, storm sewers or sanitary sewers, or the construction of buildings or other structures. (4) “Discharge” means the addition or introduction of stormwater into the MS4 or into waters of the United States. (5) “Detention” means the temporary storage of stormwater to be released at a pre-determined and controlled rate. (6) “Extended dry detention facility” means a detention basin constructed in a manner so as to retain stormwater for a time sufficient for sediments and particulate pollutants to settle and designed so that no stormwater is intended to remain in the basin after the discharge is complete. (7) “Facility” or “facilities” means a detention, retention, or other stormwater storage or handling measure as described in this section and may, depending on the context in which the term is used, include an amenity pond. (8) “Managing Director” means the Managing Director of Engineering, Transportation, Streets, and Stormwater, or a designee of that person. (9) “Municipal separate storm sewer system” or “MS4” means the system of conveyances (including roads with drainage systems, municipal streets, catch basins, curbs, gutters, ditches, channels, or storm drains) owned and operated by the City and designed or used for collecting or conveying stormwater, and which is not used for collecting or conveying sanitary sewage. (10) “One-hundred-year storm” means a storm event having a one-percent chance of occurring in any given year. (11) “Retention facility” is a facility that provides a permanent pool of a pre-determined volume of stormwater and that is designed to provide additional capacity for the temporary storage of stormwater that may be required for detention purposes. (12) “Stabilized cover” means a uniform perennial vegetative cover established and maintained with a density of 70% or greater, or an approved equivalent stabilization measure (such as rip-rap, gabions, etc.).”
( Ordinance 6773 adopted 5/19/15 ; Ordinance 7055 , sec. 27, adopted 5/7/19 )
Ask a question about Garland law
Corpus searches the Garland sections it holds and shows the ones that match, with their citations. Free, no sign-in.