§ 13-169 — Protection required

Code of Ordinances, City of Grand Prairie, Texas (Supp. No. 117, Update 1: codified through Ordinance No. 1857-2026, adopted April 27, 2026) · Grand Prairie City Code § 13-169

Corpus is an independent public-information project, not the official City of Grand Prairie website. Stable reference: corpuslaw.us/code/9bb34481-b281-46d1-8d26-f31ae7af8500

Sec. 13-169. - Protection required.

(a) No water-service connection shall be made to any establishment where a potential or actual contamination hazard exists unless the water supply is protected in accordance with the 290 Rules and this article. The local regulatory authority shall discontinue water service if a required air gap or backflow prevention assembly is not installed, maintained, and tested in accordance with the 290 Rules and this article. (b) The backflow prevention assembly protection which is required under this article shall be from an approved list by the University of Southern California Foundation for Cross-Connection Control and Hydraulic Research, or as determined by the local regulatory authority. Each backflow prevention assembly must have been approved by the local regulatory authority or his chosen representative in conjunction with the chief plumbing inspector of the city for the use contemplated by the commercial establishment prior to installation. Failure to obtain such approval prior to installation of the backflow prevention assembly may result in the backflow prevention assembly failing to meet final approval by the local regulatory authority. The local regulatory authority shall determine the type and location of backflow assembly to be installed within the area served by the city. The assembly will be required in each of the following circumstances, but the representative is in no way limited to the following circumstances: (1) The nature and extent of any activity of the premises, or the materials used in connection with any activity of the premises, or materials stored on the premises could contaminate or pollute the potable water supply. (2) Premises having any one (1) or more potential or existing cross-connections that are identified or are present. (3) Internal cross-connections are present that are not correctable. (4) Intricate plumbing arrangements are present which make it impractical to ascertain whether cross-connections exist. (5) There is a repeated history of cross-connections being established or reestablished. (6) There is unduly restricted entry so that inspections for cross-connections cannot be made with sufficient frequency to assure that cross-connections do not exist. (7) Materials are being used such that if backflow should occur a health hazard could result from contaminants. (8) Installation of an approved backflow prevention assembly is deemed to be necessary to accomplish the purpose of these regulations in the judgement of the city. (9) An appropriate cross-connection survey or customer service inspection report form has not been filed with the environmental quality division of the city upon request of the city. (10) A fire sprinkler system is connected to the city's water system. (11) All new construction, if deemed necessary in the customer service inspection. The type of assembly will be commensurate with the degree of hazard as determined by the local regulatory authority. (12) When a building is constructed on commercial premises, and the end use of such building is not determined or could change, a reduced pressure principle backflow prevention assembly may be installed at the service connection that supplies water for public domestic use. (13) Any used water return system. (14) In the event a point-of-use assembly has not had the testing or repair done as required by this article, a premises isolation assembly will be required. (15) If it is determined that additions or alterations have been made to the plumbing system without obtaining proper permits, premises isolation may be required. (16) All multistory buildings or any building with a booster pump or elevated storage tank. (17) Retrofitting will be required on all high hazard connections and wherever else the local regulatory authority deems necessary to retrofit. (c) No backflow prevention assembly may be removed from use or relocated, nor may one assembly be substituted for another, without prior approval of the local regulatory authority. (d) All backflow prevention assemblies shall be installed in a manner for easy access. If an assembly must be installed higher than five (5) feet above grade, a permanent platform shall be installed around the assembly. Any currently installed backflow prevention assemblies which, in the opinion of the local regulatory authority, are located in inaccessible locations, or where the tester is subject to physical danger, shall be relocated to an approved location. (e) Any premises requiring multiple service connections for adequacy of supply and/or fire protection will be required to install a backflow assembly on each service connection. The type of assembly will be determined by the degree of potential hazard as determined by the local regulatory authority in order to protect the public water system from contamination or pollution. (f) No person shall install or maintain a backflow prevention assembly upon or within any city right-of-way except as provided in this section. (1) A backflow prevention assembly required by the city may be installed upon or within any city right-of-way only if the owner proves to the city that there is no other feasible location for installing the assembly and installing it in the right-of-way will not interfere with traffic or utilities. The city retains the right to approve or deny the location, height, depth, enclosure, and other requisites of the assembly prior to its installation. (2) All permits and inspections required by the city Code to perform work in the right-of-way shall be obtained. (3) The assembly shall be installed below or flush with the surrounding grade except when it is not practicable to install it in this manner. Any assembly or portion of an assembly which extends above ground shall be located no closer than eighteen (18) inches to the face of the curb. (4) The city shall not be liable for any damage done to or caused by an assembly installed in a right-of-way. (5) A property owner shall, at the request of the city and at the owner's sole expense, relocate a backflow prevention assembly which encroaches upon any city right-of-way when such relocation is necessary for the city's reconstruction, widening, or straightening of streets; placement or installation of traffic signals, traffic signs and streetlights; or utility construction or repairs for purposes of public safety or other city public improvement projects. (6) A person commits an offense if he/she fails to relocate a backflow prevention assembly located in or upon any city right-of-way after receiving a written order from the local regulatory authority to do so. (g) It is the responsibility of any person who owns or controls property to eliminate the possibility of thermal expansion if a closed system has been created by the installation of a backflow assembly. (h) Any reduction in water pressure caused by the installation of a backflow assembly is not the responsibility of the city. (i) Any person who owns or controls property or establishes water service is responsible for the installation, testing and repair of all backflow assemblies on their property. (j) Air gap separations provide maximum protection from backflow hazards and may be utilized at premises where a substance is handled that would be hazardous to health if introduced into the potable water system. (k) A proper air gap is required to fill an external tank. (l) An approved double check detector backflow prevention assembly (DCDA) or reduced pressure detector assemblies (RPDAs) shall be the minimum protection for fire sprinkler systems. An RPDA must be installed if any solution other than the potable water can be introduced into the sprinkler system. (m) A permit shall be obtained from the building inspection division for all commercial and residential lawn irrigation system installations prior to any such installations. The installation requirements must comply with guidelines for the appropriate assembly found in this article. Interconnections of the potable water supply with an alternate water source is prohibited. Approved backflow protection assemblies must be installed if any mechanical injection stations are used with the irrigation system. (n) The connection of a mobile unit to any potable water system is prohibited unless such connection is protected by an air gap or an approved backflow prevention assembly. Prior approval and annual testing of any backflow prevention assembly must be received from the local regulatory authority before connecting to any potable water system. (o) The connection of an auxiliary supply is prohibited. An auxiliary supply shall mean any water source or system other than the public water system that may be available in the building or on the property. These auxiliary sources of water may include, but are not limited to, other public water system sources or other unapproved on-site source(s) which are not under the control of a public water system, such as a groundwater well, lake, spring, river, stream, harbor, and so forth. Auxiliary water sources may also include graywater, rain or stormwater, reclaimed waters, or recycled waters.

(Ord. No. 11066-2021, § 1, 9-21-21)

Ask a question about Grand Prairie law

Corpus searches the Grand Prairie sections it holds and shows the ones that match, with their citations. Free, no sign-in.