For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 13-173 — Responsibilities

Code of Ordinances, City of Grand Prairie, Texas (Supp. No. 117, Update 1: codified through Ordinance No. 1857-2026, adopted April 27, 2026) · Grand Prairie City Code § 13-173

Corpus is an independent public-information project, not the official City of Grand Prairie website. Stable reference: corpuslaw.us/code/57acf92f-d0c4-4d73-b37e-2a8b43b6995d

Sec. 13-173. - Responsibilities.

(a) Property owner. It is the responsibility of all property owners and persons in charge of any premises to abide by the conditions of this article. In the event of any changes to the plumbing system, it is the responsibility of the property owners, persons in charge of any premises, and persons who establish water service to receive prior approval for the changes from the local regulatory authority. It shall also be the responsibility of the property owners, persons in charge of any premises, and persons who establish water service to comply with the following: (1) Payment of all costs associated with this article and the purchase, installation, testing and repair of backflow prevention assemblies. (2) Install and maintain all backflow prevention assemblies in accordance with this article and acceptable industry practice. (3) All commercial establishments shall cause to have all backflow prevention assemblies on their premises tested annually during the month assigned by the local regulatory authority. Such testing must be conducted by a certified cross-connection tester who is registered with the city. (4) Maintain all backflow prevention assemblies in proper working order at all times, including repair or replacement as required. (5) Repairs or replacements shall be completed by the date established by the local regulatory authority. (6) Maintain all backflow prevention assemblies in a manner which allows them to be tested by a method that has been approved by the regulatory authority. (7) All records related to backflow prevention assembly installation, testing and repair shall be maintained on the premises for a minimum of three (3) years. (8) Requests for removal or relocation must be submitted to the local regulatory authority in writing. No backflow prevention assembly may be removed from use or relocated, nor may one assembly be substituted for another, without prior approval of the local regulatory authority. (b) Certified backflow prevention assembly tester. A certified backflow prevention assembly tester shall comply with the following requirements: (1) Annually register with the local regulatory authority and pay the annual, nonrefundable required tester registration fee established by this article. (2) Maintain testing equipment in proper working condition/calibration and provide proof that testing equipment is able to maintain a calibration of plus or minus 0.2 psid accuracy. (3) Maintain the design or operation characteristics of an assembly. (4) Test assemblies in a manner according to the most recent edition of the Manual of Cross Connection Control, published by the Foundation for Cross Connection Control and Hydraulic Research, University of Southern California, the state environmental regulatory authority, and local regulatory authority's regulations. (5) Report testing data, including accurate assembly information, test gauge serial numbers, repairs, and verify that assembly is installed as required by this article and the manufacturer, on-line through the city's approved website or on a form approved by the local regulatory authority. (6) Submit test results to the local regulatory authority within seven (7) days of testing. (7) Provide a copy of the completed test report to the property owners and/or persons in charge of any premises immediately after testing. (8) Maintain testing and/or repair records for a minimum of three (3) years. (c) After not less than ten (10) days' written notice to a backflow prevention assembly tester who is registered with the city ("the registrant"), the director may revoke said registration if the registrant fails to meet the requirements of this article. Such written notice shall include the reason for the revocation, the effective date, and instructions on how to appeal the revocation. The registrant shall have ten (10) days after receipt of the written notice from the director to submit a written request to the city manager appealing the revocation. (d) Local regulatory authority. The local regulatory authority shall have the authority and responsibility to enforce the provisions of this article and the state statutes, when applicable, regarding cross-connections. At the expense of the property owner, the local regulatory authority shall inspect and initially test, or cause to be tested, all backflow prevention assemblies installed pursuant to the requirements of this article. For new facilities, permanent water service shall not be provided until all backflow prevention assemblies have been tested and are operational. Except in cases where the testing of backflow prevention assemblies must be delayed until the installation of internal production or auxiliary equipment, the local regulatory authority shall not approve a certificate of occupancy until all backflow prevention assemblies have been tested and are operational. The city shall not be liable for damage caused to any backflow prevention assembly as a result of the inspection or testing.

(Ord. No. 11066-2021, § 1, 9-21-21)

Ask a question about Grand Prairie law

Corpus searches the Grand Prairie sections it holds and shows the ones that match, with their citations. Free, no sign-in.