§ 105-56: General standards.

In all areas of special flood hazards the following provisions are required for all new construction and substantial improvements: (1) All new construction or substantial improvements shall be designed (or modified) and adequately anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads, including the effects of buoyancy; (2) All new construction or substantial improvements shall be constructed by methods and practices that minimize flood damage and will be reasonably safe from flooding; (3) All new construction or substantial improvements shall be constructed with materials, methods, and practices that minimize flood damage, as required by the International Building Code, § 1612 flood loads; (4) All new construction or substantial improvements shall be constructed with electrical, heating, ventilation, plumbing, and air conditioning equipment and other service facilities that are designed and/or located so as to prevent water from entering or accumulating within the components during conditions of flooding; (5) All new and replacement water supply systems shall be designed to minimize or eliminate infiltration of floodwaters into the system; (6) All new and replacement sanitary sewage facilities, private sewage treatment plants (including all pumping stations and collector systems) and on-site waste disposal systems shall be designed to minimize or eliminate infiltration of floodwaters into the facilities and discharge from the facilities into floodwaters, and impairment of the facilities and systems; (7) On-site waste disposal systems shall be located to avoid impairment to them or contamination from them during flooding; (8) All public utilities and facilities such as sewer, gas, electrical, communications, and water systems shall be located and constructed to minimize or eliminate flood damage; (9) Adequate drainage shall be provided to reduce exposure to flood hazards; in Zones AH and AO, adequate drainage paths shall be provided to guide floodwaters around and away from proposed structures; (10) All new construction or substantial improvements within Special Flood Hazard Areas shall be elevated using foundation systems that meet or exceed the flood-resistance requirements of this chapter. Acceptable foundation types include: a. A stem wall foundation with an elevated slab and enclosed crawlspace, constructed using flood-damage-resistant materials. Any enclosed area below the Base Flood Elevation (BFE) shall be used solely for parking, building access, or storage, and shall include compliant flood openings in accordance with FEMA Technical Bulletin I. b. An open foundation system consisting of posts, piers, piles, or columns, provided the space below the lowest floor is either not enclosed or is enclosed only with compliant flood venting. c. Other foundation systems approved by the Floodplain Administrator, provided they meet or exceed the performance standards of this chapter and conform to ASCE 24-14 or successor standards. (11) New construction and substantial improvements, when located in multiple flood zones with varying base flood elevations or in the same flood zone with multiple base flood elevations must meet the requirements for the flood zone with the most stringent requirements and the highest base flood elevation.

( Ordinance 2026-38 adopted 8/19/2026 )

Ask a question about Harlingen law

Corpus searches the Harlingen sections it holds and shows the ones that match, with their citations. Free, no sign-in.