§ 105-59 — Standards for areas of shallow flooding (including AO/AH zones)
Code of Ordinances, City of Harlingen, Texas · Harlingen Code of Ordinances § 105-59
Corpus is an independent public-information project, not the official City of Harlingen website. Stable reference: corpuslaw.us/code/1ffe8f1d-9fdc-4141-83ee-2d083eaa1217
§ 105-59: Standards for areas of shallow flooding (including AO/AH zones).
Located within the areas of special flood hazard established in section 105-22 are areas designated as shallow flooding. These areas have special flood hazards associated with flood depths of one to three feet where a clearly defined channel does not exist, where the path of flooding is unpredictable, and where velocity flow may be evident. Such flooding is characterized by ponding or sheet flow; therefore, the following provisions apply: (1) All new construction and substantial improvements of residential structures, including manufactured homes, have the lowest floor (including basement) elevated 18 inches above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet on the community's FIRM or base level engineering assessment (at least 24 inches if no depth number is specified). (2) All new construction and substantial improvements of non-residential structures: a. Have the lowest floor (including basement) elevated to or above the base flood elevation or the highest adjacent grade at least as high as the depth number specified in feet or inches on the community's FIRM or base level engineering assessment (at least 24 inches if no depth number is specified), or b. Together with attendant utility and sanitary facilities be designed so that below the base specified flood depth in an AO Zone, or below the base flood elevation in an AH Zone, or estimated flood depth in a base level engineering assessment, level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads of effects of buoyancy. (3) A registered professional engineer or architect shall submit a certification to the Floodplain Administrator that the standards of this section, as proposed in article IV, section 105-43 are satisfied. (4) Require within Zones AH or AO adequate drainage paths around structures on slopes, to guide floodwaters around and away from proposed structures.
( Ordinance 2026-38 adopted 8/19/2026 )
Ask a question about Harlingen law
Corpus searches the Harlingen sections it holds and shows the ones that match, with their citations. Free, no sign-in.