For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 109-127 — Specifications and details

Code of Ordinances, City of Harlingen, Texas · Harlingen Code of Ordinances § 109-127

Corpus is an independent public-information project, not the official City of Harlingen website. Stable reference: corpuslaw.us/code/87ebc619-c92e-4ec4-9fa0-4b65a9eca35b

§ 109-127: Specifications and details.

(a) City specifications and details. Specifications and details governing subdivision design shall be as prescribed by the city subdivision development guide. This manual is available online at the city website or by request through the city engineering department. (b) Water facilities. (1) Public water systems. a. Where potable water is to be supplied to a subdivision by connection to Harlingen Waterworks System, the distribution system within the subdivision shall be designed and constructed in accordance with the minimum criteria set forth in 30 TAC ch. 290, subch. D, and the standards and requirements of the Harlingen Waterworks System. b. Where potable water is to be supplied by 30 TAC ch. 290, subch. F, a written statement by the water purveyor must be provided that indicates the water purveyor agrees to provide potable water to the development at the demand, both daily and peak flow rates, for a minimum period of 30 years. (2) Non-public water systems. Where individual wells are proposed for the supply of potable water to any residential lot within the subdivision, the following conditions and requirements shall be observed: a. Existing wells within a one-quarter mile radius of the subdivision or a test well or wells shall be drilled and the waters sampled and submitted to a private laboratory for a complete chemical and bacteriological analysis of the parameters on which there are potable water standards. The results of such analysis shall be made available to prospective property owners and copies of the laboratory results shall be provided the city and Harlingen Waterworks. b. The water quality of individual wells must, after treatment, meet the standards of quality for community water systems established by 30 TAC ch. 290, subch. F. c. If additional treatment is necessary to provide water meeting the above standards for potable water, a report of such treatment shall accompany the laboratory results. (3) Reinforced concrete low-head pressure pipe (for irrigation). Concrete or PVC pipes may be used, but must meet the specifications as set out by the Harlingen Irrigation District. (c) Sanitary sewer facilities. (1) Organized wastewater facility. a. Connection to Harlingen Waterworks' wastewater system shall be required except where Harlingen Waterworks determines such connection will require unreasonable expenditure when compared with other methods of wastewater disposal. b. Developers who propose the development of an organized wastewater collection and treatment system must obtain a permit to dispose of wastes from the TNRCC in accordance with to 30 TAC ch. 305 and obtain approval of engineering planning materials for such systems under 30 TAC ch. 217 and from the state. c. Developers who propose to dispose of wastewater by connecting to an existing permitted facility must provide a written agreement with the permittee. The agreement must accommodate the total flow anticipated from the ultimate development and occupancy of the proposed subdivision for a minimum of 30 years. Engineering plans for the proposed wastewater collection lines must be in accordance with state rules and approved by the water provider prior to construction. (2) On-site facilities. a. On-site facilities which serve single-family or multifamily residential dwellings with anticipated wastewater production of 1,000 or more gallons per day must be designed by a registered professional engineer or registered professional sanitarian. b. Proposals for on-site sewerage facilities for the on-site disposal of sewage in the amount of 5,000 gallons per day or greater must be presented to the state for determination of the necessity for a wastewater permit from that agency. Each such disposal facility must be designed by a registered professional engineer. c. On-site sewerage facilities not required to obtain a wastewater permit from the state must apply for and receive a permit from the Texas Department of Health or its authorized agent as required by the procedures established in 30 TAC ch. 285. d. The Texas Department of Health or its authorized agent shall review proposals for on-site sewage disposal systems and make inspections of such systems as necessary to ensure that the system is in compliance with V.T.C.A. Health and Safety Code ch. 366 and TAC ch. 285 and any additional applicable rules. In addition to the unsatisfactory on-site disposal systems prohibited by the state, pit privies and portable toilets are not acceptable waste disposal systems for lots platted under these rules.

( Ordinance 2022-52 , § 1, adopted 12/21/2022 )

Ask a question about Harlingen law

Corpus searches the Harlingen sections it holds and shows the ones that match, with their citations. Free, no sign-in.