§ 17-80 — Sewer system and connections; design and construction
Code of Ordinances of the City of Killeen, Texas (Supp. No. 38, Update 2: codified through Ordinance of 26-029, enacted August 4, 2026) · Killeen City Code § 17-80
Corpus is an independent public-information project, not the official City of Killeen website. Stable reference: corpuslaw.us/code/b44403be-6bc3-4069-91ee-6f133e3f2c70
Sec. 17-80. - Sewer system and connections; design and construction.
(a) All sewer lines shall be constructed of material acceptable to FHA. The lines should be laid in trenches separated a safe distance from any drinking water supply line under pressure. (b) Sewers shall be at a grade which will ensure a velocity of two (2) feet per second when the sewer is flowing full. (c) All joints in the sewer line shall be made watertight, and every effort shall be made to minimize groundwater infiltration into the sewerage system. (d) All sewer connections and manholes shall be constructed so as to prevent surface water from entering the sanitary sewers. (e) Cleanouts extending to grade shall be installed at fifty-foot intervals on four-inch lines, and at one-hundred-foot intervals for larger diameters. (f) All cleanouts shall be capped with cleanout plugs.
(Code 1963, Ch. 3, art. 9, § 8(I.5) [Ord. No. 71-7, § 2, 3-22-71])