Sec. 17-86. - Electrical distribution system.
All lines from meter base breaker boxes to the mobile home or travel trailer shall be buried at least eight (8) inches belowground, and shall be not less than one (1) foot radial distance from water, sewer, gas, or communication lines. All electrical requirements set forth in the appropriate state and local codes shall be complied with. All electric meters shall be permanently installed in a location accessible from an interior street, alley, or all-weather walkway. Wiring from the pole meter base to the trailer breaker box shall be not less than the size of the wiring from the breaker box to the trailer. Wiring from the meter base to eight (8) inches underground and from the trailer supply box to eight (8) inches underground shall be installed in approved conduit.
(Code 1963, Ch. 3, art. 9, § 8(I)(4) [Ord. No. 71-7, § 2, 3-22-71])