§ 3.4 — Easements

Code of Ordinances, City of Laredo, Texas (Supp. No. 23, Update 3: codified through Ordinance No. 2026-O-92, adopted May 4, 2026) · Laredo Code of Ordinances § 3.4

Corpus is an independent public-information project, not the official City of Laredo website. Stable reference: corpuslaw.us/code/8920ff2d-7709-4645-ad53-407fbd109a4a

Section 3.4: - Easements

A. Rear Lot Utility Easements: Easements across lots or centered on rear lot lines shall be provided for utilities where necessary and shall be at least twelve (12) feet wide. Utility easements centered on side lot lines shall be at least ten (10) feet wide. If the required easement is along a plat boundary with adjacent unplatted land, or platted land, or platted with an adjacent utility easement, the minimum rear lot easement width required is six (6) feet, the minimum side lot easement is five (5) feet. Such easements may be required across parts of lots other than as described above upon recommendation of the City Engineer or Utilities Director. B. Front Lot Utility Easements: The developer of a residential (single family R-1, R-1A, R-1B or R-1MH) subdivision, may, in his/her sole discretion, choose to locate utilities (electric, gas, telephone and cable) within the front yard setbacks of the lots within the subdivision in an easement that is six feet wide being no less than four feet from the front property line and no more than ten feet from the front property line of each lot and meet the following minimum requirements. 1. All transformers, pedestals, boxes or any other distribution boxes or pedestals shall be placed within the easement and shall be centered on the side yard property line with the transformers placed nearest to the street and pedestals or other boxes aligned behind the transformer box. 2. A developer who chooses to place utilities (electric, gas, telephone and television/internet, cable) in the front of the lots of a residential subdivision shall submit a written notice of the developer's intention to place front of lot utilities at the same time the preliminary plat is submitted. The front of lot utility layout/schematics, as prepared by Developer's engineer, shall be submitted to plan review after preliminary plat approval has been granted. The preliminary and final plat shall clearly show the location of the front of lot utility easement. 3. Trenches shall be not more than twenty-four inches wide nor less than fifty-two inches deep. 4. Only electric utility primary and secondary cable shall be placed at the fifty-two inch depth, or lower as may be specified by the electric utility provider and covered with a minimum twenty-four inches of fill. 5. Telephone, Cable and Gas shall be placed no more than twenty-four inches below grade within the same trench. 6. All back fill shall be at 95% compaction or as set out in the Standard Technical Specification Manual, flowable backfill may be used if it meets the following: A. Cement. Portland Cement shall conform to the requirements of the latest revision of ASTM Designation C150, Type 1, or Type II. Only one brand or kind of cement shall be used in any one structure or trench except as permitted in writing by the City Engineer. All cement shall be delivered in bags plainly marked with the brand and name of the manufacturer. B. Fine Aggregate. Provide fine aggregate that will stay in suspension in the mortar to the extent required for proper flow and that meets the gradation requirements of the aggregate gradation chart below. Test fine aggregate gradation in accordance with Tex-401-A. Plasticity Index (PI) must not exceed 6 when tested in accordance with Tex-106-A. C. Mixing Water. Use mixing water conforming to the requirements of TxDOT Item 421, "Hydraulic Cement Concrete." 7. The utility easement may extend into the lot along the side yard property line so long as it centered on the side yard lot line and does not extend past the side yard setback line (being five feet on each side of the side yard lot line) to a point where it intersects with the projection of the front of the house's foundation. This additional easement extension is to be used for the utilities service lines to the house. 8. The developer and builders shall ensure that driveways are not constructed on the same side of the lot where a transformer has been or will be placed. 9. In the event of any conflict between the above requirements and the City of Laredo Standard Technical Specification Manual, the Standard Technical Specification Manual shall control. C. All utilities shall be designed and installed in conformance with the City of Laredo Standard Technical Specification Manual, as amended from time to time and [Standard Specification Manual] upon the approval of the Utilities Director and City Engineer. Where the subdivider installs the utilities with private contractor, all the engineering covering plans and specifications shall be accomplished by him and approved by the Engineering Department of the City of Laredo prior to the start of any installation. All engineering work shall be accomplished by persons qualified under State of Texas laws to do such work. It shall be at the discretion of the City whether construction of sewer and water lines within the subdivision will be contracted to private companies or whether City forces will accomplish the installations. D. The Director of Utilities shall provide the Commission with a statement that the proposed water and sewer system for the subdivision meets their current engineering standards for water and sewer service, prior to Commission approval of the subdivision. E. As the City of Laredo has rights to the water of the Rio Grande to only a limited extent, and that it is expected that the City's demand for water will exceed its supply within the planning period that this document addresses, the following is required: All subdivisions within the jurisdiction of this ordinance, and outside the Laredo city limits as of the date of passage of this ordinance, shall provide to the Laredo Utilities Department those water rights (or money in lieu thereof) that are fair and equitable for the creation of any additional lots that the system will have to serve.

(As Amended 12/4/84, Ordinance #84-0-199; As Amended 8/20/12, Ordinance #2012-O-108; 7/6/16, Ordinance #2016-O-075)

Ask a question about Laredo law

Corpus searches the Laredo sections it holds and shows the ones that match, with their citations. Free, no sign-in.