§ 4-28 — Same—Amendments
Code of Ordinances of the City of Lewisville, Texas (Supp. No. 34: codified through Ordinance No. 0854-26-ORD, adopted July 6, 2026) · Lewisville City Code § 4-28
Corpus is an independent public-information project, not the official City of Lewisville website. Stable reference: corpuslaw.us/code/661a15ac-3c99-485a-ab33-8f379c16e2e3
Sec. 4-28. - Same—Amendments.
The city adopts the following revisions and additions to the International Building Code 2021 Edition. Section 101.1; amend to read as follows: 101.1 Title. These regulations shall be known as the Building Code of the City of Lewisville, hereinafter referred to as "this code." Section 101.4; amend to read as follows: 101.4 Referenced codes. The other codes listed in Sections 101.4.1 through 101.4.8 and referenced elsewhere in this code, when specifically adopted, shall be considered part of the requirements of this code to the prescribed extent of each such reference. Whenever amendments have been adopted to the referenced codes and standards, each reference to said code and standard shall be considered to reference the amendments as well. Any reference to NFPA 70 or the Electrical Code shall mean the Electrical Code as adopted. Section 101.4.8; add the following: 101.4.8 Electrical. The provisions of the Electrical Code shall apply to the installation of electrical systems, including alterations, repairs, replacement, equipment, appliances, fixtures, fittings and appurtenances thereto. Section 103; amend title to read as follows: SECTION 103 DEPARTMENT OF NEIGHBORHOOD AND INSPECTION SERVICES Section 103.1; amend to read as follows: 103.1 Creation of enforcement agency. The Department of Neighborhood and Inspection Services is hereby created and the official in charge thereof shall be known as the Building Official. Section 104.2.1; delete. Section 104.10.1; delete. Section 105.2; under sub-title entitled "Building;" delete items 1, 2, 10, and 11 and re-number accordingly. Section 105.2; under sub-title entitled "Electrical;" add the following paragraph: Low-voltage systems: A permit shall not be required for constructing, installing, altering, extending, maintaining, repairing, or replacing any electrical wiring, apparatus, or equipment of any voltage of twenty-four (24) volts or less and not capable of supplying more than 50 watts of energy. Exemption for the permit requirements shall not be deemed to grant authorization for any work to be done in violation of the provisions of this Code or any other laws or ordinances of this jurisdiction. Section 108.1; amend to read as follows: 108.1 Definitions. TEMPORARY PORTABLE STORAGE UNIT. Any transportable container, storage unit, shed- like container or other portable structure that can or is used for the storage of personal property of any kind on a limited basis on residential property and which is located for such purposes outside an enclosed building other than an accessory building or shed complying with all building codes and land use requirements. TEMPORARY USE DUMPSTER shall mean portable containers (typically open on top), compactors, roll-offs, or recycling containers used on a temporary basis for the collection and storage of construction waste from ongoing permitted construction projects, house cleans, or temporary uses in residentially-zoned districts, and which is 5 cubic yards or less, but shall not include any portable, nonabsorbent, enclosed container with a close fitting cover, or doors which is capable of being serviced by mechanical equipment and which is used on a permanent basis to store large volumes of refuse and which serves as the primary method of garbage collection and disposal for a residence. OUTDOOR RECEPTACLE. Any receptacle, container or similar product which is located outdoors and designed or intended to collect and temporarily store items, including a dumpster, temporary use dumpster, recycling storage container, donation container, trash compactor or receptacle for similar uses. Section 108.2; amend to read as follow: 108.2 Temporary Structures and Uses. It shall be the responsibility of the homeowner and or provider of a Temporary Portable Storage Unit to notify the Department of Neighborhood and Inspection Services of the placement. A Temporary Portable Storage Unit may remain at a site used for residential purposes for up to thirty (30) calendar days, with one portable storage unit allowed at a site at a time. There will be 2 allowances per calendar year. An extension may be granted by Code Enforcement and/or the Department of Neighborhood and Inspection Services and subject to conditions, for a reasonable additional period in an amount not to exceed thirty (30) days. Temporary Portable Storage Units may be located in residential zoning districts and shall only be placed on the property owner's driveway or parking area and only so long as they do not obstruct vehicular or pedestrian traffic and provided the units are not placed in the set-back, encroaching into drainage areas/easements or landscaping buffers, or the right-of-way. Such units shall not be placed in such a manner that a person lawfully using the sidewalk must detour into the street in order to go around the unit. Temporary Portable Storage Units shall not be used to store solid waste, construction debris, demolition debris, recyclable materials, business inventory, commercial goods, goods for property other that at the residential property where the Temporary Portable Storage Unit is located (i.e. used for retail sales) or any other illegal or hazardous material. Upon reasonable notice to the resident, the City may inspect the contents of any Temporary Portable Storage Unit at any reasonable time to ensure that it is not being used to store said materials. At no time shall a Temporary Portable Storage Unit be used for any of these purposes. Locations where a Temporary Portable Storage Unit is being used in connection with new construction or extensive renovation or repair of property, Temporary Portable Storage Units related to and used for the ongoing construction or storage of personal articles during such construction shall be allowed for the period of continuous construction provided there is an active and valid building permit for the property. Any Temporary Portable Storage Unit at the site that is not specifically related to and used in connection with the construction shall be subject to the limits otherwise imposed in this section of the code. Within 5 calendar days of expiration of a building permit, passage of all final inspections, or issuance of a certificate of occupancy (whichever is later), the Temporary Portable Storage Unit shall be removed. Section 108.3; amend to read as follow: 108.3 Temporary Use Dumpsters—Duration. A temporary use dumpster may remain at a site used for residential purposes for up to thirty (30) calendar days, with one temporary use dumpster allowed at a site at a time. There will be 2 allowances per calendar year allowed. An extension may be granted by Code Enforcement and/or the Department of Neighborhood and Inspection Services and subject to conditions, for a reasonable additional period in an amount not to exceed thirty (30) days. Locations where a temporary use dumpster is being used in connection with new construction or extensive renovation or repair of property shall be allowed for the period of continuous construction provided there is an active and valid building permit for the property. Any temporary use dumpster at the site that is not specifically related to and used in connection with the construction shall be subject to the limits otherwise imposed in this section of the code. Within 5 calendar days of expiration of a building permit, passage of all final inspections, or issuance of a certificate of occupancy (whichever is later), the temporary use dumpster shall be removed. Section 108.4; amend to read as follow: 108.4 Severe Weather Conditions. At all times Temporary Portable Storage Units and Temporary Use Dumpsters shall be secured or removed in such a manner so as to minimize the danger of such units causing damage to persons or property from high winds or severe weather conditions. Section 108.5; add to read as follows: Section 108.5, Outdoor Receptacle. This section applies to outdoor receptacles on any property designated as non-residential zoning district, multi-family zoning district and mixed use zoning district, as defined by the Lewisville Zoning Ordinance, placed on said property after the passage of this ordinance. Section 108.5.1; add to read as follows: 108.5.1. Approval required. (a) It shall be unlawful for any person, firm, or corporation to erect, place, maintain or operate any outdoor receptacle without first obtaining approval from the City's Neighborhood and Inspection Services Department. (b) Information from the applicant including a drawing showing location, size and the number of such receptacles shall be submitted to the City prior to placement of the receptacles on the property. Section 108.5.2; add to read as follows: 108.5.2. Screening and placement. (a) Outdoor receptacles shall be screened on 3 sides with a minimum six (6) foot masonry screening wall consistent with the building material of the primary building(s). The service opening shall not directly face a public street or ROW unless approved by the Director of Neighborhood and Inspection Services due to the site configuration that may not allow such a design. The receptacles shall be located on a concrete or asphalt surface. (b) Outdoor receptacles shall be located behind the primary building front façade(s). (c) Outdoor receptacles shall not be located within any utility easements, fire lanes, public ROW or easement, required parking or loading spaces, maneuvering lanes, access easements or landscape areas. Section 108.5.3; add to read as follows: 108.5.3. Maintenance. Outdoor receptacles shall be sized and designed to contain all material between designated pick up schedules. Any overflow above or around the outdoor receptacle is strictly prohibited. All clean up shall be the responsibility of the property owner. Section 109.2; amend to read as follow: 109.2 Schedule of permit fees. All fees under this code shall be assessed as set forth in the Lewisville City Code, Chapter 2, Section 2-201. Section 109.4; amend to read as follows: 109.4 Work commencing before permit issuance. Whenever work for which a permit is required by this code has been commenced without first obtaining a permit, an investigation fee, in addition to the permit fee, shall be collected whether or not a permit is subsequently issued. The investigation fee shall be equal to the amount of the permit fee required by this code. The payment of such investigation fee shall not exempt the applicant from compliance with all other provisions of either this code or the technical codes nor from penalty prescribed by law. Section 109.7; add to read as follows: 109.7 Re-inspection Fee. A fee as outlined in Section 2-201 of the Lewisville City Code may be charged when: 1. The inspection called for is not ready when the inspector arrives; 2. No building address or permit card is clearly posted; 3. City approved plans are not on the job site available to the inspector; 4. The building is locked or work otherwise not available for inspection when called; 5. The job site is red-tagged twice for the same item; 6. The original red tag has been removed from the job site. 7. Failure to maintain erosion control, trash control or tree protection. Any re-inspection fees assessed shall be paid before any more inspections are made on that job site. Section 109.8; add to read as follows: 109.8 Unauthorized cover up fee. Any work concealed without first obtaining the required inspection in violation of Section 110 shall be charged a fee as outlined in Section 2-201 of the Lewisville City Code. Section 112.3; amend to read as follows: 112.3 Authority to disconnect service utilities. The building official shall have the authority to authorize disconnection of utility service to the building, structure or system regulated by this code and referenced codes and standards in case of emergency when necessary to eliminate an immediate hazard to life or property, where such utility connection has been made without the approval required by Sections 112.1 or 112.2, or when a certificate of occupancy has been revoked for the building or structure. 112.3.1 Pre-disconnection notice. Prior to any non-emergency disconnection, the building official shall provide notice of such disconnection via United States regular mail and certified mail, return receipt requested, and by posting notice on the front door of the building or structure. (a) The notice shall: (1) specify the reason for the planned disconnection and what action must be taken to cure; (2) specify the date upon which utilities will be disconnected, which shall be no earlier than seven (7) calendar days from the date of the notice; (3) provide the owner or occupant seven (7) business days from the date of the notice to request a meeting regarding the disconnection in order to present evidence to the Director of Neighborhood and Inspection Services, and provide instructions for requesting a meeting. (b) If the owner or occupant requests a meeting with the Director of Neighborhood and Inspection Services, the meeting shall be held within three (3) working days of such request. (c) The Director of Neighborhood and Inspection Services shall issue a written decision regarding the disconnection within three (3) working days of the meeting. (d) If the owner or occupant requests a meeting as provided for herein, the disconnection shall be stayed until the Director of Neighborhood and Inspection Services has issued his written decision. (e) The process outlined herein shall be utilized in lieu of the appeal process provided for in Section 113. (f) In case of emergency where disconnection of utility service is necessary to eliminate an immediate hazard to life or property, the owner or occupant shall be notified in writing of the decision to disconnect prior to disconnection when possible. 112.3.2 Post-disconnection notice. In case of emergency where disconnection of utility service is necessary to eliminate an immediate hazard to life or property and pre-disconnection notice is not possible, the owner or occupant shall be notified in writing via United States regular mail and certified mail, return receipt requested within two (2) working days following the disconnection, and by posting notice on the front door of the building or structure within twenty-four (24) hours of the disconnection. Section 113.1; amend to read as follows: 113.1 Means of Appeal. An individual directly affected by an order, decision, or determination made by the building official relative to the application and interpretation of this code may appeal such order, decision, or determination. In order to hear and decide appeals of orders, decisions, or determinations made by the building official relative to the application and interpretation of this code, the City Council shall act as the Board of Appeals. An appeal must be filed in writing with the City Manager within thirty (30) days after the date of the order, decision, or determination. After receiving an appeal in accordance with this section, the City Manager shall submit the appeal to the City Council for their consideration. The City Council's decision on the appeal shall be the final decision. Section 113.3; delete in its entirety. Section 114.2; add exception to read as follows: Exception: Citations for violations of this code may be issued without requiring the issuance of a notice. Section 114.3; amend to read as follows: 114.3 Prosecution of violation. If a notice of violation is issued and is not complied with in the time prescribed by such notice, the building official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceedings at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto. Section 114.4; amend to read as follows: 114.4 Violation penalties. Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, installs, alters or repairs a building or structure in violation of the approved construction documents or directive of the building official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by Section 1-15 of the Code of Ordinances of the City of Lewisville. Each day that a violation continues shall be deemed a separate offense. Section 116; delete in its entirety. Section 202; amend definition of "Ambulatory Care Facility" as follows: AMBULATORY CARE FACILITY. Buildings or portions thereof used to provide medical, surgical, psychiatric, nursing, or similar care on a less than 24-hour basis to persons who are rendered incapable of self-preservation by the services provided. This group may include but not be limited to the following: - Dialysis centers - Providers of procedures involving sedation - Providers of sedation dentistry - Surgery centers - Colonic centers - Psychiatric centers Section 202; add definition of "Assisting Living Facilities" to read as follows: ASSISTED LIVING FACILITIES. A building or part thereof housing persons, on a 24-hour basis, who because of age, mental disability or other reasons, live in a supervised residential environment which provides personal care services. The occupants are capable of responding to an emergency situation without physical assistance from staff. Section 202; amend definition of "High-Rise Building" to read as follows: HIGH-RISE BUILDING. A building with an occupied floor located more than 55 feet (16,764 mm) above the lowest level of fire department vehicle access. Section 202; add definition of "Repair Garage" as follows: REPAIR GARAGE. A building, structure or portion thereof used for servicing or repairing motor vehicles, motorcycles, recreational vehicles, and watercraft. This occupancy shall also include garages involved in minor repair, modification and servicing of motor vehicles for items such as lube changes, inspections, windshield repair or replacement, shocks, minor part replacement and other such minor repairs. Section 202; amend definition of "Special Inspector" to read as follows: SPECIAL INSPECTOR. A qualified person employed or retained by an approved agency who shall prove to the satisfaction of the registered design professional in responsible charge and the Building Official as having the competence necessary to inspect a particular type of construction requiring special inspection. Section 303.1.3; add a sentence to read as follows: 303.1.3 Associated with Group E occupancies. A room or space used for assembly purposes that is associated with a Group E occupancy is not considered a separate occupancy except when applying the assembly requirements of Chapters 10 and 11. Section 304.1; add the following to the list of occupancies: Fire stations Police stations with detention facilities for 5 or less Section 307.1.1, Exception 4; add language to read as follows: 4. Cleaning establishments… {Text unchanged} …with Section 707 or 1-hour horizontal assemblies constructed in accordance with Section 711 or both. See also IFC Chapter 21, Dry Cleaning Plant provisions. Section 403.1, Exception 3; amend to read as follows: 3. The open-air portion of a building containing a Group A-5 occupancy in accordance with Section 303.6 Section 403.3; delete exception. Section 403.3.2; amend to read as follows: [F] 403.3.2 Water supply to required fire pumps. In buildings that are more than 120 feet (36.5 m) in building height, required fire pumps shall be supplied by connections to no fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate. Exception: {No change to exception.} Section 404.10; amend to read as follows: Section 404.10 Exit stairways in an atrium. Where an atrium contains an exit access stairway, all of the following shall be met: {Remainder unchanged.} Section 406.3.3.1; add sentence to read as follows: A fire separation is not required between a Group R-2 and U carport provided that the carport is entirely open on all sides and that the distance between the two is at least 10 feet (3,048 mm). Section 423.5.1; amend to read as follows: Section 423.5.1 Required occupant capacity. The required occupant capacity of the storm shelter shall include all of the buildings on the site and shall be the total occupant load of the classrooms, vocational rooms and offices in the Group E occupancy. Exceptions: 1. Where a new building is being added on an existing Group E site, and where the new building is not of sufficient size to accommodate the required occupant capacity of the storm shelter for all of the buildings on the site, the storm shelter shall at a minimum accommodate the required occupant capacity for the new building. 2. Where approved by the building official, the required occupant capacity of the shelter shall be permitted to be reduced by the occupant capacity of any existing storm shelters on the site. 3. Where approved by the building official, the actual number of occupants for whom each occupied space, floor or building is designed, although less than those determined by occupant load calculation, shall be permitted to be used in the determination of the required design occupant capacity for the storm shelter. Section 506.3.1; add sentence to read as follows: 506.3.1 Minimum percentage of perimeter. {Existing text to remain} In order to be considered as accessible, if not in direct contact with a street or fire lane, a minimum 10-foot wide pathway meeting fire department access from the street or approved fire lane shall be provided. Section 602.1.1; add sentence to read as follows: Section 708.4.2; amend exception to read as follows: 708.4.2 Fireblocks and draftstops in combustible construction. {Body of text unchanged} Exceptions: 1. Buildings equipped with an automatic sprinkler system installed throughout in accordance with Section 903.3.1.1, or in accordance with Section 903.3.1.2 provided that sprinkler protection is provided in the space between the top of the fire partition and the underside of the floor or roof sheathing, deck or slab above as required for systems complying with Section 903.3.1.1. Portions of buildings containing concealed spaces filled with noncombustible insulation as permitted for sprinkler omission shall not apply to this exception for draftstopping. {Remainder unchanged} Section 718.3; amend exception to read as follows: 718.3 Draftstopping in floors. {Body of text unchanged} Exceptions: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. and provided that in combustible construction, sprinkler protection is provided in the floor space. Section 718.4; amend exception to ready as follows: 718.4 Draftstopping in attics. {Body of text unchanged} Exceptions: Buildings equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1 and provided that in combustible construction, sprinkler protection is provided in the attic space. Section 901.6.1.1; add section to read as follows: 901.6.1.1 Standpipe Testing. Building owners/managers must maintain and test standpipe systems as per NFPA 25 requirements. The following additional requirements shall be applied to the testing that is required every 5 years: 1. The piping between the Fire Department Connection (FDC) and the standpipe shall be backflushed or inspected by approved camera when foreign material is present or when caps are missing, and also hydrostatically tested for all FDC's on any type of standpipe system. Hydrostatic testing shall also be conducted in accordance with NFPA 25 requirements for the different types of standpipe systems. 2. For any manual (dry or wet) standpipe system not having an automatic water supply capable of flowing water through the standpipe, the tester shall connect hose from a fire hydrant or portable pumping system (as approved by the fire code official) to each FDC, and flow water through the standpipe system to the roof outlet to verify that each inlet connection functions properly. Confirm that there are no open hose valves prior to introducing water into a dry standpipe. There are no required pressure criteria at the outlet. Verify that check valves function properly and that there are no closed control valves on the system. 3. Any pressure relief, reducing, or control valves shall be tested in accordance with the requirements of NFPA 25. All hose valves shall be exercised. 4. If the FDC is not already provided with approved caps, the contractor shall install such caps for all FDC's as required by the fire code official. 5. Upon successful completion of standpipe test, place a blue tag (as per Texas Administrative Code, Fire Sprinkler Rules for Inspection, Test and Maintenance Service (ITM) Tag) at the bottom of each standpipe riser in the building. The tag shall be check-marked as "Fifth Year" for Type of ITM, and the note on the back of the tag shall read "5 Year Standpipe Test" at a minimum. 6. The procedures required by Texas Administrative Code Fire Sprinkler Rules with regard to Yellow Tags and Red Tags or any deficiencies noted during the testing, including the required notification of the local Authority Having Jurisdiction (fire code official) shall be followed. 7. Additionally, records of the testing shall be maintained by the owner and contractor, if applicable, as required by the State Rules mentioned above and NFPA 25. 8. Standpipe system tests where water will be flowed external to the building shall not be conducted during freezing conditions or during the day prior to expected night time freezing conditions. 9. Contact the fire code official for requests to remove existing fire hose from Class II and III standpipe systems where employees are not trained in the utilization of this firefighting equipment. All standpipe hose valves must remain in place and be provided with an approved cap and chain when approval is given to remove hose by the fire code official. Section 901.7; amend to read as follows: 901.7 Systems out of service. Where a required fire protection system is out of service or in the event of an excessive number of activations, the fire department and the fire code official shall be notified immediately and, where required by the fire code official, the building shall either be evacuated or an approved fire watch shall be provided for all occupants left unprotected by the shut down until the fire protection system has been returned to service. Where utilized, fire watches shall be provided with at least one approved means for notification of the fire department and their only duty shall be to perform constant patrols of the protected premises and keep watch for fires. Section 903.1.1; amend to read as follows: 903.1.1 Alternative protection. Alternative automatic fire-extinguishing systems complying with Section 904 shall be permitted in addition to automatic sprinkler protection where recognized by the applicable standard, or as approved by the fire code official. Section 903.2; delete the exception and amend to read as follows: 903.2 Where required. Approved automatic sprinkler systems shall be provided in the locations described in Sections 903.2.1 through 903.2.12, and as follows: 1. Commercial buildings—Automatic sprinkler systems will be required in all newly constructed buildings exceeding 3,600 square feet of fire area, any remodel or addition that changes the square footage beyond 3,600 square feet or any single tenant expansion requiring a new certificate of occupancy that exceeds 12,000 square feet of fire area. Whichever requirement listed in this chapter, including exceptions, or defined in this amendment that is more restrictive will apply. Credit will not be given for fire barrier walls with a fire resistive rating in lieu of automatic fire sprinkler systems. 2. Whenever Section 903.2 requires the installation of an approved automatic sprinkler system, the automatic sprinkler system shall be installed throughout the entire building. Exceptions: 1. In strip mall buildings, the installation of fire barrier walls with not less than a two-hour fire resistive rating may be allowed to separate the occupancy from the rest of the building in lieu of providing fire sprinkler protection throughout the entire building as approved by the fire code official. 2. When a change in Occupancy Classification is required for an existing building or tenant space, the building or tenant space shall comply with the provisions of Section 903.2. Automatic Sprinklers shall not be installed in elevator machine rooms, elevator machine spaces, and elevator hoistways, other than pits where such sprinklers would not necessitate shunt trip requirements under any circumstances. Storage shall not be allowed within the elevator machine room. Signage shall be provided at the entry doors to the elevator machine room indicating "ELEVATOR MACHINERY - NO STORAGE ALLOWED." Section 903.2.1; amend to read as follows: 903.2.1 Group A. An automatic fire sprinkler system shall be installed throughout the entire building housing a Group A occupancy as provided in this section. Section 903.2.1.1; amend to read as follows: 903.2.1.1 Group A-1. An automatic sprinkler system shall be provided throughout the entire building housing a Group A-1 occupancy where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. 4. The fire area contains a multitheater complex. Section 903.2.1.2; amend to read as follows: Section 903.2.1.2 Group A-2. An automatic sprinkler system shall be provided throughout the entire building housing a Group A-2 occupancies where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet. 2. The fire area has an occupant load of 100 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. Section 903.2.1.3; amend to read as follows: 903.2.1.3 Group A-3. An automatic sprinkler system shall be provided throughout the entire building housing a Group A-3 occupancy where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. Section 903.2.1.4; amend to read as follows: 903.2.1.4 Group A-4. An automatic sprinkler system shall be provided throughout the entire building housing a Group A-4 occupancy where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet. 2. The fire area has an occupant load of 300 or more. 3. The fire area is located on a floor other than a level of exit discharge serving such occupancies. Section 903.2.1.6; delete exception and amend to read as follows: 903.2.1.6 Assembly occupancies on roofs. Where an occupied roof has an assembly occupancy with an occupant load in excess of 100 persons, the entire building shall be equipped with an automatic fire sprinkler system in accordance with Section 903.3.1.1 or 903.3.1.2. Section 903.2.2: amend to read as follows: Ambulatory care facilities. An automatic fire sprinkler system shall be installed throughout the entire building housing an ambulatory care facility when any of the following conditions exist: 1. The fire area exceeds 3,600 square feet. 2. Four or more care recipients are incapable of self-preservation, whether rendered incapable by staff or staff has accepted responsibility for care recipients already incapable. 3. One or more care recipients that are incapable of self-preservation are located at other than the level of exit discharge serving such facility. In buildings where ambulatory care is provided on levels other than the level of exit discharge, an automatic sprinkler system shall be installed throughout the entire building. Section 903.2.1.8; add a new section to read as follows: 903.2.1.8 Group B. An automatic sprinkler system shall be provided for Group B occupancies where the fire area exceeds 3,600 square feet. Section 903.2.3; amend to read as follows: 903.2.3 Group E. An automatic sprinkler system shall be provided for Group E occupancies as follows: 1. Where the fire area exceeds 3,600 square feet. 2. (Unchanged) 3. (Unchanged) Section 903.2.4; amend to read as follows: 903.2.4 Group F-1. An automatic sprinkler system shall be provided throughout all buildings containing a Group F-1 occupancy where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet; 2. (Unchanged) 3. (Unchanged) 4. (Unchanged) Section 903.2.4.2, amend to read as follows: 903.2.4.2 Group F-1 distilled spirits. An automatic sprinkler system shall be provided throughout a Group F-1 fire area used for the manufacture of distilled spirits involving more than 120 gallons of distilled spirits (>16% alcohol) in the fire area at any one time. Section 903.2.4.4; add a new section to read as follows: 903.2.4.2 Group F-2. An automatic sprinkler system shall be provided for Group F-2 occupancies where the fire area exceeds 3,600 square feet. Section 903.2.6; amend to read as follows: Section 903.2.6 Group I. An automatic fire sprinkler system shall be provided throughout buildings with a Group I fire area in accordance with Section 903.3.1.1. Section 903.2.7; amend to read as follows: 903.2.7 Group M. An automatic sprinkler system shall be provided throughout buildings containing a Group M occupancy when the fire area exceeds 3,600 square feet or for Group M occupancies located more than three stories above grade plane. Section 903.2.8; amend to read as follows: 903.2.8. Group R. An automatic sprinkler system shall be provided throughout all buildings with a Group R occupancies and shall include the following criteria: 1. Throughout Groups R-1, 2, and 4 occupancies in all areas, including but not limited to attics, balconies, breezeways, garages and exterior storerooms, shall have an approved hydraulically designed fire sprinkler system installed. 2. Residential or quick response standard sprinklers shall be used in dwelling units and guestroom portions of the building. 3. Attics are to be sprinklered in accordance with NFPA 13 except that allowable sprinkler omissions for attics as outlined in NFPA shall not be allowed. Section 903.2.9; amend to read as follows: 903.2.9 Group S-1. An automatic sprinkler system shall be provided throughout where one of the following conditions exists: 1. The fire area exceeds 3,600 square feet; 2. A Group S-1 occupancy is located more than three stories above the grade plane; or 3. A Group S-1 occupancy used for the storage of upholstered furniture or mattresses exceeds 2,500 square feet. Section 903.2.9.1; amend to read as follows: 903.2.9.1 Repair Garages. An automatic fire sprinkler system shall be provided throughout all buildings used as repair garages in accordance with Section 406 if: 1. The fire area exceeds 3,600 square feet; or 2. Buildings with repair garages servicing vehicles parked in basements. Section 903.2.9.2; amend to read as follows: 903.2.9.2 Bulk storage of tires. Buildings and structures where the area for the storage of tires exceeds 20,000 cubic feet or 3,600 square feet shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1. Section 903.2.9.3; amend to read as follows: 903.2.9.3 Group S-1 distilled spirits or wine. An automatic sprinkler system shall be provided throughout a Group S-1 fire area used for the bulk storage of distilled spirits or wine involving more than 120 gallons of distilled spirits or wine (>16% alcohol) in the fire area at any one time. Section 903.2.9.4; delete exception. Section 903.2.9.5; add a new section to read as follows: 903.2.9.5 Self-service storage facility. An automatic sprinkler system shall be installed throughout all self-service storage facilities. Section 903.2.10; amend to read as follows: 903.2.10 Group S-2 parking garages. An automatic fire sprinkler system shall be installed throughout buildings classified as parking garages where either of the following conditions exists: 1. The fire area exceeds 3,600 square feet, or 2. Where the enclosed parking garage is located beneath other groups. Section 903.2.10.1; amend to read as follows: 903.2.10.1 Commercial parking garages. An automatic fire sprinkler system shall be installed throughout buildings used for storage of commercial motor vehicles where the fire area exceeds 3,600 square feet. Section 903.2.10.2; add section to read as follows: 903.2.10.2 Open Parking Garages. An automatic fire sprinkler system shall be installed throughout all open parking garages. Exception: Automatic fire sprinkler systems are not required when all sides of the open parking garage are separated from adjacent buildings or property lines by a fire apparatus lane conforming to Section 503.2 of the Fire Code and no occupancies are located above the subject garage. Section 903.2.11.3; delete exceptions and amend to read as follows: 903.2.11.3 Buildings 35 feet or more in height. An automatic sprinkler system shall be installed throughout buildings with a floor level, other than penthouses in compliance with Section 1510 of the International Building Code, located 35 feet or more above the lowest level of fire department vehicle access, measured to the finished floor. Automatic sprinkles shall be installed throughout all stories to, and including, the level of exit discharge. Section 903.2.11.7; add a new section to read as follows: 903.2.11.7 High-Piled Combustible Storage. For any building with a clear height exceeding 12 feet (4,572 mm), see Chapter 32 of the International Fire Code to determine if those provisions apply. Section 903.2.11.8; add a new section to read as follows: 903.2.11.8 Spray Booths and Rooms. New and existing spray booths and spraying rooms shall be protected by an approved automatic fire-extinguishing system. Section 903.3.1.1.1; amend to read as follows: 903.3.1.1.1 Exempt locations. When approved by the fire code official, automatic sprinklers shall not be required in the following rooms or areas where such rooms or areas are protected with an approved automatic fire detection system in accordance with Section 907.2 that will respond to visible or invisible particles of combustion. Sprinklers shall not be omitted from any room merely because it is damp, of fire-resistance-rated construction or contains electrical equipment. In such locations, an alternative fire suppression or detection system may be required by the fire code official. 1. Any room where the application of water, or flame and water, constitutes a serious life or fire hazard. 2. Any room or space where sprinklers are considered undesirable because of the nature of the contents, when approved by the fire code official. 3. Generator and transformer rooms, under the direct control of a public utility, separated from the remainder of the building by walls and floor/ceiling or roof/ceiling assemblies having a fire-resistance rating of not less than 2 hours. 4. Elevator machine rooms, machinery spaces, and hoistways, other than pits where such sprinklers would not necessitate shunt trip requirements under any circumstances. Section 903.3.1.2; amend to read as follows: 903.3.1.2 NFPA 13R sprinkler systems. Automatic sprinklers systems in Group R occupancies shall be permitted to be installed throughout in accordance with NFPA 13R where the Group R occupancy meets all of the following conditions: 1. Four stories or less above grade plane. 2. The floor level of the highest story is 35 feet (10,668 mm) or less above the lowest level of fire department vehicle access. 3. The floor level of the lowest story is 35 feet (10,668 mm) or less below the lowest level of fire department vehicle access. The number of stories of Group R occupancies constructed in accordance with Section 510.2 and 510.4 shall be measured from grade plane. Section 903.3.1.2.1; amend to read as follows: 903.3.1.2.1 Balconies and decks. Sprinkler protection shall be provided for exterior balconies, decks, and ground floor patios of dwelling units and sleeping units, provided there is a roof or deck above. Sidewall sprinklers that are used to protect such areas shall be permitted to be located such that their deflectors are within 1 inch to 6 inches below the structural members and a maximum distance of 14 inches below the deck of the exterior balconies and decks that are constructed of open wood joist construction. Section 903.3.1.2.2; amend to read as follows: Section 903.3.1.2.2 Corridors and balconies in the means of egress. Sprinkler protection shall be provided in all corridors and for all balconies in the means of egress. Section 903.3.1.2.3; amend to read as follows: Section 903.3.1.2.3 Attics, Exterior Storerooms, and Attached Garages. Sprinkler protection is required in attic spaces of such buildings, exterior storerooms, and attached garages. Attic automatic fire sprinkler systems shall be installed per NFPA 13. Section 903.3.1.3; amend to read as follows: 903.3.1.3 NFPA 13D sprinkler systems. Automatic sprinkler systems installed in one- and two-family dwellings, Group R-3, Group R-4 Condition 1 and townhouses shall be permitted to be installed throughout in accordance with NFPA 13D or in accordance with state law. Section 903.3.1.4; add new sections to read as follows: 903.3.1.4 Freeze protection. Freeze protection systems for automatic fire sprinkler systems shall be in accordance with the requirements of the applicable referenced NFPA standard and this section. 903.3.1.4.1 Attics. Only dry-pipe, preaction, or listed antifreeze automatic fire sprinkler systems shall be allowed to protect attic spaces. Exception: Wet-pipe fire sprinkler systems shall be allowed to protect non-ventilated attic spaces where: 1. The attic sprinklers are supplied by a separate floor control valve assembly to allow ease of draining the attic system without impairing sprinklers throughout the rest of the building, and 2. Adequate heat shall be provided for freeze protection as per the applicable referenced NFPA standard, and 3. The attic space is a part of the building's thermal, or heat, envelope, such that insulation is provided at the roof deck, rather than at the ceiling level. 903.3.1.4.2 Heat trace/insulation. Heat trace/insulation shall only be allowed where approved by the fire code official for small sections of large diameter water-filled pipe. Section 903.3.5; amend to read as follows: 903.3.5 Water supplies. Water supplies for automatic sprinkler systems shall comply with this section and the standards referenced in Section 903.3.1. The potable water supply shall be protected against backflow in accordance with the requirements of this section and the International Plumbing Code. For connections to public waterworks systems, the water supply test used for design of fire protection systems shall be adjusted to account for seasonal and daily pressure fluctuations based on information from the water supply authority and as approved by the fire code official. Water supply as required for such systems shall be provided in conformance with the supply requirements of the respective standards; however, every fire protection system shall be designed with a 10-psi safety factor. Reference Section 507.4 for additional design requirements. Section 903.3.8; amend to read as follows: 903.3.8 Limited area sprinkler systems. When approved by the fire code official and not in conflict with Section 903.2(2), limited area sprinkler systems shall be in accordance with the standards listed in Section 903.3.1 except as provided in Sections 903.3.8.1 through 903.3.8.5. Section 903.4; amend to read as follows: 903.4 Sprinkler system supervision and alarms. All valves controlling the water supply for automatic sprinkler systems, pumps, tanks, water levels and temperatures, critical air pressures and water-flow switches on all sprinkler systems shall be electrically supervised by a listed fire alarm control unit. Exceptions: {All exceptions to remain unchanged} Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. Section 903.4.2; add second paragraph to read as follows: 903.4.2 Alarms. An approved audible device, located on the exterior of the building in an approved location, shall be connected to each automatic sprinkler system. Such sprinkler water-flow alarm devices shall be activated by water flow equivalent to the flow of a single sprinkler of the smallest orifice size installed in the system. Where a fire alarm system is installed, actuation of the automatic sprinkler system shall actuate the building fire alarm system. The alarm device required on the exterior of the building shall be a weatherproof horn/strobe notification appliance with a minimum 75 candela strobe rating, installed as close as practicable to the fire department connection. Section 903.4.2.1; add a new section to read as follows: 903.4.2.1 Multiple tenant buildings. A minimum of one horn/strobe notification appliance shall be installed in each tenant space of a multiple tenant building to notify occupants of an automatic fire sprinkler system water-flow condition. Section 903.6; add a new section to read as follows: 903.6 Where required in existing buildings and structures. An automatic sprinkler system shall be provided in existing buildings and structures where required in Chapter 11 of the Fire Code and, when a change in Occupancy Classification is required for an existing building or tenant space, the building or tenant space shall comply with the provisions of the new Occupancy Classification as stated in Section 903.2. Section 903.7; add a new section to read as follows: 903.7 Fire Control Rooms. A fire control room is required for all new automatic sprinkler system installations. The fire control room shall comply with the following: 1. Located on an exterior wall adjacent to a fire apparatus access lane. 2. Be a minimum size of 5-foot by 7-foot. 3. Shall house the system riser, fire alarm control panel, and spare sprinkler heads. 4. Have an exterior entry door that measures at a minimum 36-inch by 80-inch, and shall be identified as FIRE CONTROL ROOM, with a minimum of 4-inch characters, on the exterior of the door. 5. Be equipped with an exterior horn/strobe device indicating a water-flow alarm. Device shall be located above the FDC, 120-inches above finished floor 6. The riser shall be located a minimum of 12-inches from any wall. 7. A "Knox" key box shall be located on the exterior of the fire control room, adjacent to the exterior door, installed 5-feet above finished floor, and shall house a key to open the exterior door. 8. Room shall be kept free of any storage. Section 905.2; amend to read as follows: 905.2 Installation standard. Standpipe systems shall be installed in accordance with this section and NFPA 14. Manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low alarm. Section 905.3.9; add a new section to read as follows: 905.3.9 Buildings exceeding 10,000 square feet. In buildings exceeding 10,000 square feet in area per story and where any portion of the building's interior area is more than 200 feet (60,960 mm) of travel, vertically and horizontally, from the nearest point of fire department vehicle access, Class I automatic wet or manual wet standpipes shall be provided. Exceptions: 1. Automatic dry, semi-automatic dry, and manual dry standpipes are allowed as provided in NFPA 14 where approved by the fire code official. 2. R-2 occupancies of four stories or less in height having no interior corridors. Section 905.4; amend to reach as follows: 905.4 Location of Class I standpipe hose connections. Class I standpipe hose connections shall be provided in all of the following locations: 1. In every required exit stairway, a hose connection shall be provided for each story above and below the grade plane. Hose connections shall be located at an intermediate landing between stories unless otherwise approved by the fire code official. Exception: {No change.} 2. {No change.} 3. In every exit passageway, at the entrance from the exit passageway to other areas of a building. Exception: Where floor areas adjacent to an exit passageway are reachable from an exit stairway hose connection by a 30-foot (9,144 mm) hose stream from a nozzle attached to 100 feet (30,480 mm) of hose, a hose connection shall not be required at the entrance from the exit passageway to other areas of the building. 4. {No change.} 5. Where the roof has a slope less than 4 units vertical in 12 units horizontal (33.3-percent slope), each standpipe shall be provided with a two-way hose connection located to serve the roof or at the highest landing of an exit stairway with stair access to the roof provided in accordance with Section 1011.12. 6. {No change.} 7. When required by the Chapter, standpipe connections shall be placed adjacent to all required exits to the structure and at two (200) feet intervals along major corridors thereafter, or as otherwise approved by the fire code official. Section 905.8; amend to read as follows: Section 905.8 Dry standpipes. Dry standpipes shall not be installed. Exception: Where subject to freezing and in accordance with NFPA 14. Additionally, manual dry standpipe systems shall be supervised with a minimum of 10 psig and a maximum of 40 psig air pressure with a high/low supervisory alarm. Section 905.9; amend to read as follows: 905.9 Valve supervision. Valves controlling water supply shall be supervised in the open position so that the change in the normal position of the valve will generate a supervisory signal at the supervising station required by Section 903.4. Where a fire alarm system is provided, a signal shall also be transmitted to the control unit. Exceptions: 1. Valve to underground key or hub valves in roadway boxes provided by the municipality or public utility do not require supervision. 2. Valves locked in the normal position and inspected as provided in this code in buildings not equipped with a fire alarm system. Sprinkler and standpipe system water-flow detectors shall be provided for each floor tap to the sprinkler system and shall cause an alarm upon detection of water flow for more than 45 seconds. All control valves in the sprinkler and standpipe systems except for fire department hose connection valves shall be electrically supervised to initiate a supervisory signal at the central station upon tampering. Section 906.1(1); delete Exception #3 in its entirety. 907.1.4; add a new section to read as follows: 907.1.4 Design standards. Where a new fire alarm system is installed, the devices shall be addressable. Fire alarm systems utilizing more than 20 smoke detectors shall have analog initiating devices. Section 907.2.1; amend to read as follows: 907.2.1 Group A. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group A occupancies having an occupant load of 300 or more persons or more than 100 persons above or below the lowest level of exit discharge. Group A occupancies not separated from one another in accordance with Section 707.3.10 of the International Building Code shall be considered as a single occupancy for the purposes of applying this section. Portions of Group E occupancies occupied for assembly purposes shall be provided with a fire alarm system as required for the Group E occupancy. Exception: Manual fire alarm boxes are not required where the building is equipped throughout with an automatic sprinkler system installed in accordance with Section 903.3.1.1 and the occupant notification appliances will activate throughout the notification zones upon sprinkler water flow. Activation of fire alarm notification appliances shall: 1. Cause illumination of the means of egress with light of not less than 1 foot-candle (11 lux) at the walking surface level, and 2. Stop any conflicting or confusing sounds and visual distractions. Section 907.2.3; amend to read as follows: 907.2.3 Group E. A manual fire alarm system that initiates the occupant notification signal utilizing an emergency voice/alarm communication system meeting the requirements of Section 907.5.2.2 and installed in accordance with Section 907.6 shall be installed in Group E educational occupancies. When automatic sprinkler systems or smoke detectors are installed, such systems or detectors shall be connected to the building fire alarm system. An approved smoke detection system shall be installed in Group E day care occupancies. Unless separated by a minimum of 100' open space, all buildings, whether portable buildings or the main building, will be considered one building for alarm occupant load consideration and interconnection of alarm systems. Exceptions: 1. A manual fire alarm system is not required in Group E occupancies with an occupant load of less than 50. 1.1. Residential in-home day care with not more than 12 children may use interconnected single station detectors in all habitable rooms. (For care of more than five children 2½ or less years of age, see Section 907.2.6.) {No change to remainder of exceptions.} Section 907.2.10; amend to read as follows: Section 907.2.10 Group S. A manual fire alarm system that activates the occupant notification system in accordance with Section 907.5 shall be installed in Group S public and self-storage occupancies for interior corridors and interior common areas. Visible notification appliances are not required within storage units. Exception: {No change.} Section 907.2.13, Exception 3; amend to read as follows: 3. Open air portions of buildings with an occupancy in Group A-5 in accordance with Section 303.1 of the International Building Code; however, this exception does not apply to accessory uses including but not limited to sky boxes, restaurants and similarly enclosed areas. Section 907.4.2.; add a new section to read as follows: 907.4.2.7 Type. Manual alarm initiating devices shall be an approved double action type. Section 907.6.1.1; add a new section to read as follows: 907.6.1.1 Wiring Installation. All fire alarm systems shall be installed in such a manner that a failure of any single initiating device or single open in an initiating circuit conductor will not interfere with the normal operation of other such devices. All signaling line circuits (SLC) shall be installed in such a way that a single open will not interfere with the operation of any addressable devices (Class A). Outgoing and return SLC conductors shall be installed in accordance with NFPA 72 requirements for Class A circuits and shall have a minimum of four feet separation horizontal and one foot vertical between supply and return circuit conductors. The initiating device circuit (IDC) from an addressable input (monitor) module may be wired Class B, provided the distance from the addressable module to the initiating device is ten feet or less. Section 907.6.3; delete all exceptions. Section 907.6.6; amend to read as follows: Section 907.6.6 Monitoring. Fire alarm systems required by this chapter or by the International Code shall be monitored by an approved supervising station in accordance with NFPA 72. See Section 907.6.3 for the required information transmitted to the supervising station. Section 910.2.3; add a new section to read as follows: 910.2.3 Group H. Buildings and portions thereof used as a Group H occupancy as follows: 1. In occupancies classified as Group H-2 or H-3, any of which are more than 15,000 square feet in single floor area. Exception: Buildings of noncombustible construction containing only noncombustible materials. 2. In areas of buildings in Group H used for storing Class 2, 3, and 4 liquid and solid oxidizers, Class 1 and unclassified detonable organic peroxides, Class 3 and 4 unstable (reactive) materials, or Class 2 or 3 water-reactive materials as required for a high-hazard commodity classification. Exception: Buildings of noncombustible construction containing only noncombustible materials. Sections 910.3.4.1; add a new section to read as follows: 910.3.4.1 Sprinklered buildings. Where installed in buildings equipped with an approved automatic sprinkler system, smoke and heat vents shall be designed to operate automatically. The automatic operating mechanism of the smoke and heat vents shall operate at a temperature rating at least 100 degrees F greater than the temperature rating of the sprinklers installed. Exception: Manual only systems per Section 910.2. Sections 910.3.4.2; add a new section to read as follows: 910.3.4.2 Nonsprinklered buildings. Where installed in buildings not equipped with an approved automatic sprinkler system, smoke and heat vents shall operate automatically by actuation of a heat-responsive device rated at between 100°F and 220°F above ambient. Exception: Listed gravity-operated drop out vents. Section 910.4.3.1; amend to read as follows: 910.4.3.1 Makeup Air. Makeup air openings shall be provided within 6 feet (1,829 mm) of the floor level. Operation of makeup air openings shall be automatic. The minimum gross area of makeup air inlets shall be 8 square feet per 1,000 cubic feet per minute (0.74 m2 per 0.4719 m3/s) of smoke exhaust. Section 912.2.3; add a new section to read as follows: 912.2.3 Hydrant distance. An approved fire hydrant shall be located within 100 feet of the fire department connection as the fire hose lays along an unobstructed path. Section 912.3.1; add a new section to read as follows: 912.3.1 Multiple inlet fire department connections. When more than two, 2½-inch siamese connections are required for a fire department connection, in addition to the required 2½-inch siamese connections, a 5-inch Storz fitting shall be installed at a 45-degree downward angle at the end of the fire department connection manifold. Section 913.2.1.1; add a new sectin to read as follows: 913.2.1.1 Fire pump room access. When located on the ground level at an exterior wall, the fire pump room shall be provided with an exterior fire department access door that is not less than 3 ft. in width and 6 ft.—8 in. in height, regardless of any interior doors that are provided. A key box shall be provided at this door, as required by Section 506.1. Exception: When it is necessary to locate the fire pump room on other levels or not at an exterior wall, the corridor leading to the fire pump room access from the exterior of the building shall be provided with equivalent fire resistance as that required for the pump room, or as approved by the fire code official. Access keys shall be provided in the key box as required by Section 506.1. Section 914.3.1.2; amend to read as follows: 914.3.1.2 Water supply to required fire pumps. In buildings that are more than 120 feet in building height, required fire pumps shall be supplied by connections to no fewer than two water mains located in different streets. Separate supply piping shall be provided between each connection to the water main and the pumps. Each connection and the supply piping between the connection and the pumps shall be sized to supply the flow and pressure required for the pumps to operate. Exception: Two connections to the same main shall be permitted provided the main is valved such that an interruption can be isolated so that the water supply will continue without interruption through no fewer than one of the connections. Section 1006.2.1, Exception 3; amend to read as follows: 3. Unoccupied rooftop mechanical rooms and penthouses are not required to comply with the common path of egress travel distance measurement. Section 1009.8; add the following Exception 7 to read as follows: 1009.8 Two-Way Communication. A two-way communication system complying with Sections 1009.8.1 and 1009.8.2 shall be provided at the landing serving each elevator required to be accessible on each accessible floor that is one or more stories above or below the level of exit discharge. Exceptions: 7. Buildings regulated under State Law and built in accordance with State registered plans, including variances or waivers granted by the State, shall be deemed to be in compliance with the requirements of Section 1009 and chapter 11. Section 1010.2.5; amend exceptions 3 and 4 as follows: Exceptions: 3. Where a pair of doors serves an occupant load of less than 50 persons in a Group B, F, M or S occupancy (remainder unchanged). 4. Where a pair of doors serves a Group A, B, F, M or S occupancy (remainder unchanged). Section 1020.1; add Exception 6 to read as follows: 6. In group B occupancies, corridor walls and ceilings need not be of fire-resistive construction within a single tenant space when the space is equipped with approved automatic smoke-detection within the corridor. The actuation of any detector shall activate self-annunciating alarms audible in all areas within the corridor. Smoke detectors shall be connected to an approved automatic fire alarm system where such system is provided. Section 1101.1; add exception to Section 1101.1 as follows: Exception: Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. Section 1704.2; amend to read as follows: 1704.2 Special inspections and tests. Where application is made to the building official for construction as specified in Section 105, the owner or the owner's authorized agent, or the registered design professional in responsible charge, other than the contractor, shall employ one or more approved agencies to provide special inspections and tests during construction on the types of work listed under Section 1705 and identify the approved agencies to the building official. The special inspector shall not be employed by the contractor. These special inspections and tests are in addition to the inspections identified by the building official that are identified in Section 110. Exceptions: {Remainder unchanged.} Section 1704.2.1; amend to read as follows: 1704.2.1 Special inspector qualifications. Prior to the start of construction and or upon request, the approved agencies shall provide written documentation to the registered design professional in responsible charge and the building official demonstrating the competence and relevant experience or training of the special inspectors who will perform the special inspections and tests during construction. {Remainder unchanged.} Section 1809.5.1; delete in its entirety. Section 2702.5; add a new section to read as follows: 2702.5 Designated Critical Operations Areas (DCOA). In areas within a facility or site requiring continuous operation for the purpose of public safety, emergency management, national security or business continuity, the power systems shall comply with NFPA 70 Article 708. Section 2901.1; amend to read as follows: [P] 2901.1 Scope. {existing text to remain} The provisions of this Chapter are meant to work in coordination with the provisions of Chapter 4 of the International Plumbing Code. Should any conflicts arise between the two chapters, the building official shall determine which provision applies. Section 2902.1; add a second paragraph to read as follows: In other than E Occupancies, the minimum number of fixtures in Table 2902.1 may be lowered, if requested in writing, by the applicant stating reasons for a reduced number and approved by the Building Official. Table 2902.1; add footnote g to read as follows: g. Drinking fountains are not required in M Occupancies with an occupant load of 100 or less, B Occupancies with an occupant load of 25 or less, and for dining and/or drinking establishments. Section 2902.1.4; add a new section to read as follows: 2902.1.4 Additional fixtures for food preparation facilities. In addition to the fixtures required in this Chapter, all food service facilities shall be provided with additional fixtures set out in this section. Section 2902.1.4.1; add a new section to read as follows: 2902.1.4.1 Hand washing lavatory. At least one hand washing lavatory shall be provided for use by employees that is accessible from food preparation, food dispensing and ware washing areas. Additional hand washing lavatories may be required based on convenience of use by employees. Section 2902.1.4.2; add a new section to read as follows: 2902.1.4.2 Service sink. In new or remodeled food service establishments, at least one service sink or one floor sink shall be provided so that it is conveniently located for the cleaning of mops or similar wet floor cleaning tool and for the disposal of mop water and similar liquid waste. The location of the service sink(s) and/or mop sink(s) shall be approved by the City of Lewisville's Health Department. Section 3002.1; add exceptions to Section 3002.1 as follows: Exceptions: 4. Elevators completely located within atriums shall not require hoistway enclosure protection. 5. Elevators in open or enclosed parking garages that serve only the parking garage, shall not require hoistway enclosure protection. Section 3005.4; delete exceptions and add two new exceptions as follows: Exceptions: 1. Elevator machine rooms, control rooms, machinery spaces and control spaces completely located within atriums shall not require enclosure protection. 2. Elevator machine rooms, control rooms, machinery spaces and control spaces in open or enclosed parking garages that serve only the parking garage, shall not require enclosure protection. Section 3005.5; add a new section to read as follows: 3005.5.1 Fire Protection in Machine rooms, control rooms, machinery spaces and control spaces. 3005.5.1.1 Automatic sprinkler system. The building shall be equipped throughout with an automatic sprinkler system in accordance with Section 903.3.1.1, except as otherwise permitted by Section 903.3.1.1.1 and as prohibited by Section 3005.7.2.1. 3005.5.1.1.1 Prohibited locations. Automatic sprinklers shall not be installed in machine rooms, elevator machinery spaces, control rooms, control spaces and elevator hoist-ways. 3005.5.1.1.2 Sprinkler system monitoring. The sprinkler system shall have a sprinkler control valve supervisory switch and water-flow initiating device provided for each floor that is monitored by the building's fire alarm system. 3005.5.1.2 Water protection. An approved method to prevent water from infiltrating into the hoistway enclosure from the operation of the automatic sprinkler system outside the elevator lobby shall be provided. 3005.5.1.3 Shunt trip. Means for elevator shutdown in accordance with Section 3005.5 shall not be installed. Section 3005.8; add a new section to read as follows: 3005.8 Storage. Storage shall not be allowed within the elevator machine room, control room, machinery spaces and or control spaces. Provide approved signage at each entry to the above-listed locations stating: "No Storage Allowed." Section 3006.2; amend Section 5 to read as follows: 5. The building is a high rise and the elevator hoistway is more than 55 feet (16,764 mm) in height. The height of the hoistway shall be measured from the lowest floor at or above grade to the highest floors served by the hoistway. Section 3007.3; amend to read as follows: 3007.3 Water protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method. Section 3008.3; amend to read as follow: 3008.3 Water protection. Water from the operation of an automatic sprinkler system outside the lobby shall be prevented from infiltrating into the hoistway enclosure in accordance with an approved method. Section 3109.1; amend to read as follows: 3109.1 General. Swimming pools shall comply with the requirements of Chapter 4, Buildings and Building Regulations, Article XI, Swimming Pools of the Lewisville City Code and other applicable sections of this code and complying with applicable state laws.
(Ord. No. 4037-12-2013, § 3, 12-16-13; Ord. No. 4098-08-2014, § 1, 8-4-14; Ord. No. 4223-11-2015, §§ 1, 2, 11-2-15; Ord. No. 4270-05-2016, § 2, 5-2-16; 0238-20-ORD, § 2, 8-17-20; 0612-23-ORD, § 2, 11-6-23)
Ask a question about Lewisville law
Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.