Sec. 4-35. - Same—Amendments.

The city adopts the following revisions and additions to the International Existing Building Code 2021 Edition. Section 101.1; amend to read as follows: 101.1 Title. These Regulations shall be known as the Existing Building Code of the City of Lewisville, hereinafter referred to as "this code". Section 102.4; change to read as follows: 102.4 Referenced codes and standards. The codes, when specifically adopted, and standards referenced in this code shall be considered part of the requirements of this code to the prescribed extent of each such reference and as further regulated in Sections 102.4.1 and 102.4.2. Section 103; amend title to read as follows: SECTION 103 DEPARTMENT OF NEIGHBORHOOD AND INSPECTION SERVICES Section 103.1; amend to read as follows: 103.1 Creation of enforcement agency. The Department of Neighborhood and Inspection Services is hereby created and the official in charge thereof shall be known as the building official. The function of the agency shall be the implementation, administration and enforcement of the provisions of this code. Section 104.3; amend to read as follows: 104.3 Notices and orders. The code official is authorized to issue necessary notices and orders to ensure compliance with this code. Section 104.8; delete. Section 104.8.1; delete. Section 108.2; amend to read as follows: 108.2 Schedule of permit fees. Where a permit is required, a fee for each permit shall be paid as required in accordance with Section 2-201 of the Lewisville City Code. Section 112.1; amend to read as follows: 112.1. Means of Appeal. An applicant may appeal any order, decision, or determination made by the code official relative to the application and interpretation of this code. In order to hear and decide appeals of orders, decisions, or determinations made by the code official relative to the application and interpretation of this code, the City Council shall act as the Board of Appeals. An appeal must be filed in writing with the City Manager within thirty (30) days after the date of the order, decision, or determination. After receiving an appeal in accordance with this section, the City Manager shall submit the appeal to the City Council for their consideration. The City Council's decision on the appeal shall be the final decision. Sections 112.2 through 112.4; delete. Section 113.2; add exception to read as follows: Exception: Citations for violations of this code may be issued without requiring the issuance of a notice. Section 113.3; amend to read as follows: 113.3 Prosecution of violation. If a notice of violation is issued and is not complied with in the time prescribed by such notice, the code official is authorized to request the legal counsel of the jurisdiction to institute the appropriate proceedings at law or in equity to restrain, correct or abate such violation, or to require the removal or termination of the unlawful occupancy of the structure in violation of the provisions of this code or of the order or direction made pursuant hereto. Section 113.4; amend to read as follows: 113.4 Violation penalties. Persons who violate a provision of this code or fail to comply with any of the requirements thereof or who repairs or alters or changes the occupancy of a building or structure in violation of the approved construction documents or directive of the code official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by Section 1-15 of the Code of Ordinances of the City of Lewisville. Each day that a violation continues shall be deemed a separate offense. Section 202; amend definition of Code Official as follows: CODE OFFICIAL. The official or other designated authority charged with the administration and enforcement of this code. May also be referred to as the "building official." Section 202; amend definition of Existing Building as follows: EXISTING BUILDING. A building, structure, or space with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; or a change of occupancy. Section 202; amend definition of Existing Structure as follows: EXISTING STRUCTURE. A building, structure, or space, with an approved final inspection issued under a code edition which is at least 2 published code editions preceding the currently adopted building code; or a change of occupancy. Section 306.1; add exceptions to read as follows: Exception: 1. Components of projects regulated by and registered with Architectural Barriers Division of Texas Department of Licensing and Regulation shall be deemed to be in compliance with the requirements of this chapter. 2. If the cost of the project is less than $50K, it must comply with ICC A117.1, or it shall be reviewed and inspected to the Texas Accessibility Standards by a Registered Accessibility Specialist. Section 306.2; add exception to read as follows: Exception: Projects subject to the Texas Accessibility Standards as adopted by the Texas Department of Licensing and Regulation are exempt from this section. Projects with a valuation of less than $50,000.00 (which are subject to the Texas Accessibility Standards) may be accepted as equivalent to this section where reviewed and inspected to the Texas Accessibility Standards by a Texas Department of Licensing and Regulation Registered Accessibility Specialist when a plan review report and a compliant inspection report are provided to the building code official. Section 306.5.1; amend to read as follows: 306.5.1 Complete change of occupancy. Where an entire building undergoes a change of occupancy, it shall comply with Section 305.4.1 and shall have all of the following accessible features: 1. Not fewer than one accessible building entrance. 2. Not fewer than one accessible route from an accessible building entrance to primary function areas. 3. Signage complying with Section 1111 of the International Building Code. 4. Accessible parking, where parking is being provided. 5. Not fewer than one accessible passenger loading zone, where loading zones are provided. 6. Not fewer than one accessible route connecting accessible parking and accessible passenger loading zones to an accessible entrance. 7. At least one accessible family or assisted use toilet room shall be provided in accordance with Chapter 11 of the International Building Code. Where it is technically infeasible to comply with the new construction standards for any of these requirements for a change of group or occupancy, Items 1 through 6 shall conform to the requirements to the maximum extent technically feasible. Exception: The accessible features listed in Items 1 through 6 are not required for an accessible route to Type B units. Section 401.3; delete in its entirety. Section 405.2.6; delete in its entirety. Section 406.1; amend to read as follows: 406.1 Material. Existing electrical wiring and equipment undergoing repair shall be allowed to be repaired or replaced with like material, in accordance with the requirements of NFPA 70. Section 502.3, delete in its entirety. Section 503.2; delete in its entirety. Section 503.16; add exception to read as follows: Exception: Compliance with the Texas Accessibility Standards is not considered equivalent compliance for the purpose of this code section. Section 504.1.2; amend to read as follows: 504.1.2 Existing fire escapes. Existing fire escapes shall continue to be accepted as a component in the means of egress in existing buildings only. Existing fire escapes shall be permitted to be repaired or replaced. Section 504.1.3; delete in its entirety. Section 507.3; delete in its entirety. Section 701.3; delete in its entirety. Section 702.4; add exception 2 to read as follows: 2. Operable windows with openings that are provided with window fall prevention devices that comply with ASTM F2090. Section 702.7; amend to read as follows: 702.7 Materials and methods. All new work shall comply with the materials and methods requirements in the building code, energy conservation code, mechanical code, electrical code, and plumbing code of the City of Lewisville, that specify material standards, detail of installation and connection, joints, penetrations, and continuity of any element, component, or system in the building. Section 802.5.1; amend to read as follows: 802.5.1 Minimum requirement. Every portion of open-sided walking surfaces, including mezzanines, equipment platforms, aisles, stairs, ramps and landings that is more than 30 inches (762 mm) above the floor or grade below and is not provided with guards, or those in which the existing guards are judged to be in danger of collapsing, shall be provided with guards. Section 803.1; add sentence to read as follows: For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls capable of resisting the passage of smoke containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. Section 803.2.6; amend exception to read as follows: Exception: Supervision is not required where the Fire Code does not require such for new construction. Section 803.3; amend to read as follows: 803.3 Standpipes. Refer to Section 1103.6 of the Fire Code for retroactive standpipe requirements. {Delete rest of Section 803.3.} Section 804.2; delete Exception #1. Section 804.4.1.2; amend to read as follows: 804.4.1.2 Fire Escapes required. For other than Group I-2, where more than one exit is required an existing fire escape complying with section 805.3.1.2.1 shall be accepted as providing one of the required means of egress. Section 804.4.1.2.1; amend to read as follows: 804.4.1.2.1 Fire Escape access and details. Fire escapes shall comply with all of the following requirements: 1. {Remain unchanged} 2. Access to an existing fire escape shall be through a door, {remainder unchanged} 3. {Item deleted} 4. {Remain unchanged} 5. In all buildings of Group E occupancy up to and including the 12th grade, buildings of Group I occupancy, boarding houses, and childcare centers, ladders of any type are prohibited on fire escapes used as a required means of egress. Section 804.6.2; amend to read as follows: 804.6.2 Transoms. In all buildings of Group B, E, I-1, I-2, R-1 and R-2 occupancies, {remainder unchanged}. Section 904.1; add sentence to read as follows: For the purpose of fire sprinkler protection and fire alarm requirements included in this section, the work area shall be extended to include at least the entire tenant space or spaces bounded by walls containing the subject work area, and if the work area includes a corridor, hallway, or other exit access, then such corridor, hallway, or other exit access shall be protected in its entirety on that particular floor level. Section 904.1.1; amend to read as follows: 904.1.1 High-rise buildings. An automatic sprinkler system shall be provided in work areas of high-rise buildings. Section 1011.2.1; amend to read as follows: 1011.2.1 Fire sprinkler system. Where a change in occupancy classification occurs or where there is a change of occupancy within a space where there is a different fire protection system threshold requirement in Chapter 9 of the International Building Code that requires an automatic fire sprinkler system to be provided based on the new occupancy in accordance with Chapter 9 of the International Building Code. The installation of the automatic sprinkler system shall be required within the area of the change of occupancy and areas of the building not separated horizontally and vertically from the change of occupancy by one of the following: 1. Fire barrier, as required by Section 707 of the IBC. 2. Fire wall, as required by Section 706 of the IBC. Exceptions: {Remainder unchanged.} Section 1102.2.1; amend to read as follows: 1102.2.1 Fire Separations. Where fire separations are utilized to allow additions without exceeding the allowable area provisions of Chapter 5 of the IBC for either the existing building or the new addition, the decreased clear space where the two buildings adjoin shall be accounted for in such calculation relative to the allowable frontage increase. Section 1103.3; delete in its entirety. Section 1201.4; delete in its entirety. Section 1301.3.2; amend to read as follows: 1301.3.2 Compliance with other codes. Buildings that are evaluated in accordance with this section shall comply with the Fire Code. Section 1301.3.3; delete in its entirety.

(Ord. No. 4268-05-2016, § 2, 5-2-16; 0239-20-ORD, § 2, 8-17-20; 0615-23-ORD, § 2, 11-6-23)

Ask a question about Lewisville law

Corpus searches the Lewisville sections it holds and shows the ones that match, with their citations. Free, no sign-in.