For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 22.11.036 — Facility inspection for stormwater discharges

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 22.11.036

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/006f6a66-fda9-4f27-a8cf-9b39f62781b1

§ 22.11.036: Facility inspection for stormwater discharges.

(a) Applicability for industrial and construction activity. (1) This section applies to all facilities and construction sites located within the city limits or otherwise subject to the regulatory authority of the City of Lubbock that have stormwater discharges associated with industrial activity or construction site activity. (2) State of Texas regulations require that subject facilities apply for and obtain general permits for industrial facilities (TPDES TXR050000) and construction sites (TXR150000) that have been determined to contribute or have the potential to contribute substantial pollutant loads to the municipal stormwater drainage system or waters of the state. The general permits require that the permittee develop, implement, and maintain a stormwater pollution prevention plan (SWP3) and submit a notice of intent notifying the TCEQ and the municipal stormwater drainage system operator (City of Lubbock). (3) The MS4 permit issued to the City of Lubbock by the TCEQ mandates that the City of Lubbock "Carry out all inspections, surveillance, and monitoring procedures necessary to determine compliance with permit conditions" (Part III (E)(6)) and implement a program that includes "Inspection of construction sites and enforcement of control measure requirements" (Part III (B)(9)(b)). (4) To meet these requirements the City of Lubbock must enter onto the premises of industrial and construction sites to inspect, monitor, and conduct surveillance of requirements mandated by the TCEQ. These requirements include, but are not limited to: (A) Review of the facilities SWP3 with on-site conditions; (B) Evaluation of best management practices to effectively prohibit the discharge of non-stormwater to the municipal stormwater drainage system; (C) Inspection for illicit connections and illicit discharges; (D) Self-inspection compliance; and (E) Compliance with the city’s MS4 permit and the facilities subject general permit (TXR150000 or TXR050000). (b) Access to industrial facilities and construction sites. (1) The intent of facility inspections shall be to determine compliance with the conditions of the city’s TPDES permit, any applicable NPDES or TPDES general permits and this article. Facility and construction site owners and operators shall allow the stormwater engineer ready access to applicable sections of public and private premises for the sole purpose of inspection, surveillance, and monitoring for the presence of illegal discharges to the municipal stormwater drainage system, illicit connections to the municipal stormwater drainage system, and assessment of any portions of a regulated facility influenced by stormwater runoff that may adversely affect the municipal stormwater drainage system and/or waters of the United States. (2) Admittance to the facility or construction site shall be requested at a reasonable time during normal working hours unless it is determined by the stormwater engineer that imminent and substantial danger exists. (3) The owner or operator shall make all necessary arrangements to allow access to the stormwater engineer. (4) In the event the owner or operator refuses entry after a request to enter and inspect has been made, the city is hereby empowered to seek assistance from any court of competent jurisdiction in obtaining such entry. (5) The stormwater engineer retains the authority to collect samples and photographs from stormwater outfalls or other components of the MS4 as may be deemed appropriate in the administration and enforcement of this article. (6) The stormwater engineer shall have the authority to set up on subject facilities such devices as are necessary in the opinion of the stormwater engineer to conduct monitoring of the facilities stormwater discharge. (7) The stormwater engineer or the designated inspector must present appropriate credentials to the facility officials at the time of entry to a facility. (c) Review and modification of stormwater pollution prevention plans (SWP3). (1) The stormwater engineer retains the authority to request for review any documents or plans, including but not limited to SWP3, spill prevention control plans, hazardous material plans, and waste management documentation from a regulated facility or construction site that the stormwater engineer reasonably believes may affect stormwater discharges to the municipal stormwater drainage system. (2) The stormwater engineer may require an operator of a regulated facility or construction site to modify its SWP3 if, in the best professional judgment of the stormwater engineer, the SWP3 does not comply with the requirements of the facilities NPDES or TPDES permit to discharge stormwater associated with industrial or construction activity. (3) The deficiencies in a facility’s SWP3 will be communicated in writing, and the stormwater engineer will provide the operator a reasonable amount of time, not to exceed thirty (30) days, to make the necessary changes in the SWP3. (d) Review and modifications of best management practices (BMPs). (1) Any person engaged in activities or operation, or owning facilities or property, which will or may result in pollutants entering the MS4 or waters of the United States by means of wind and/or precipitation, shall implement BMP’s to the MEP to prevent and reduce such pollutants. The owner or operator of a regulated facility shall provide reasonable protection from accidental discharge of prohibited materials or other wastes into the MS4 or waters of the United States. Practices implemented to prevent accidental discharge of prohibited materials or other wastes shall be provided and maintained at the owner or operator’s expense. (2) The City of Lubbock will maintain a list of approved BMP’s within the City of Lubbock’s Drainage Criteria Manual. The stormwater engineer may request a demonstration of the effectiveness of implemented BMP’s. (3) The stormwater engineer may require an operator of a regulated facility to modify its BMP’s if, in the best professional judgment of the stormwater engineer, the BMP’s do not provide effective protection from accidental discharge of prohibited materials or other wastes from entering into the municipal stormwater drainage system or waters of the United States. (4) The deficiencies in a facilities BMP’s will be communicated in writing, and the stormwater engineer will provide the operator a reasonable amount of time, not to exceed sixty (60) days, to make the necessary changes in the BMP’s. Permit time requirements for controlling pollutants in runoff shall remain applicable. (e) Compliance with permit. (1) A facility or construction site shall be operated in strict compliance with the requirements of the subject TPDES permit to discharge stormwater associated with industrial or construction site activity. (2) A person commits an offense if the person operates a facility or construction site in violation of the requirements of the subject NPDES/TPDES permit to discharge stormwater associated with industrial or construction site activity.

( 1983 Code, sec. 30-56 ; Ordinance 2008-O0095 , sec. 1, adopted 11/20/2008 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.