For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.07.077 — Storage tanks, separators

Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 8.07.077

Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/7746731d-cec3-46ba-9cdf-5b5976c1b343

§ 8.07.077: Storage tanks, separators.

(a) It shall be unlawful and an offense for any person to use, construct or operate, in connection with any producing well within the city limits, any crude oil storage tanks or produced water tanks, except to the extent of two (2) low-type steel tanks for oil storage, not exceeding five hundred (500) barrels’ capacity each and so constructed and maintained as to be vaportight with appropriate safety or pressure release devices and level control devices. A permittee may use, construct and operate a steel conventional separator, and such other steel tanks and appurtenances as are necessary for treating oil with each of such facilities to be so constructed and maintained as to be vaportight. Each oil, gas separator shall be equipped with both a regulation pressure relief safety valve and a bursting head. All such tanks shall be placed upon a suitable earth or concrete pad and shall be equipped with lightning arrestor systems. (b) The tank or tanks shall be enclosed with a conventional type fire wall constructed of compacted earth; sufficient water shall be used during the fire wall construction to assure adequate compaction. (c) The fire wall enclosing the tanks shall have a minimum capacity equal to two (2) times the volume of the tanks enclosed. Drip pots shall be provided at the pump out connection to contain the liquids from the storage tanks. (d) The top or crown of the fire wall shall have a minimum height of three (3) feet above normal ground elevation. (e) The tanks shall be recessed within the fire wall enclosure to such depth that will assure them being practically “sight clear” when viewed from without the fenced enclosure. (f) The separators shall be installed for operation in a horizontal or vertical position, height not to exceed ten (10) feet above tank level. (g) Any oil or gas produced may be transported outside of the city limits by underground pipelines. (h) Each storage tank and/or separator shall be enclosed by a substantial cyclone fence a minimum of eight (8) feet in height and properly built so as to ordinarily keep persons and animals out of the enclosure, with all the gates thereto to be kept locked when the permittee or his employees are not within the enclosure. (i) Any site that produces more than one barrel of condensate per day shall install a vapor recovery unit on the site.

( 1983 Code, sec. 14-166 ; Ordinance 8327 , sec. 2 (19A-17), adopted 5/28/1982 ; Ordinance 2015-O0021 adopted 3/12/2015 )

Ask a question about Lubbock law

Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.