§ 8.07.083 — Abandonment; plugging; precautionary measures
Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 8.07.083
Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/679b31fc-8a0c-49cb-9455-f1aa39be160b
§ 8.07.083: Abandonment; plugging; precautionary measures.
Whenever any well is abandoned, it shall be the obligation of the permittee and the operator of the well to set a three hundred eighty-five (385) foot cement plug in the bottom of the surface casing with the bottom of the plug one hundred (100) feet below the surface casing section, and the top of the plug one hundred (100) feet above the surface casing section; and to set a fifty-foot cement plug in the top of the surface casing. No surface or conductor string of casing may be pulled or removed from a well. During initial abandonment operations it shall be the obligation of the permittee and the operator of the well to flood the well with mud-laden fluid weighing not less than ten (10) pounds per gallon, and the well shall be kept filled to the top with such mud-laden fluid at all times. Mud-laden fluid of the above specifications shall be left in the well bore below and between cement plugs. Any additional provisions or precautionary measures prescribed by the state, in connection with the abandonment and plugging of a well, shall be complied with by the permittee. The well site shall be restored to the original condition of the land, including any displaced landscaping and topsoil.
( 1983 Code, sec. 14-171 ; Ordinance 8327 , sec. 2 (19A-21), adopted 5/28/1982 ; Ordinance 2015-O0021 adopted 3/12/2015 )
Ask a question about Lubbock law
Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.