§ 8.07.080 — Fire prevention; escape of gas; burning or flaring gas
Code of Ordinances of the City of Lubbock, Texas (Lubbock Code of Ordinances, Charter and Unified Development Code current through Ordinance 2026-O0123 adopted September 22, 2026 (eCode360 publication LU6396, scraped 2026-11-17)) · Lubbock Code of Ordinances § 8.07.080
Corpus is an independent public-information project, not the official City of Lubbock website. Stable reference: corpuslaw.us/code/b606573f-ed16-46b8-9e1e-988495936453
§ 8.07.080: Fire prevention; escape of gas; burning or flaring gas.
(a) No permittee engaged in the drilling or operation of an oil and/or gas well within the corporate limits of the city shall permit gas to escape into the air, or flare or burn gas from a torch or any similar means within the corporate limits of the city; provided, gas may be burned for a limited time when necessary to complete an oil and/or gas well upon the original completion or upon the recompletion of workover jobs upon oil and/or gas wells, so long as the same does not constitute a fire hazard to the property of others within the vicinity of such oil and/or gas well. Such vent or open flame shall be screened with a flare bonnet or other similar device in such a way as to minimize detrimental effects to adjacent property owners. Operator shall provide notice to the fire marshal prior to any open flaring. No gas may be flared between the hours of 7:00 p.m. and 7:00 a.m., except in case of an emergency. (b) All material safety data sheets (MSDS) for all hazardous materials that will be located, stored, transported, and/or temporarily used on the operations site shall be kept on site. All hazardous materials shall be safely stored according to any applicable federal, state, or local laws, rules, and regulations. Adequate firefighting apparatus and supplies, approved by the fire department of the city shall be maintained on the drilling site at all times during drilling and production operations at the operator’s cost. The operator shall be responsible for the maintenance and upkeep of such equipment. Each well shall be equipped with an automated valve that closes the well in the event of an abnormal change in operating pressure. All well heads shall contain an emergency shut-off valve to the well distribution line. Emergency personnel must have access to the site. All machinery, equipment, and installations on all drilling sites within the city limits shall conform with such requirements as may from time to time be issued by the fire department of the city. (c) The fire marshal shall receive written notice from the applicant a minimum of one (1) week prior to commencing active drilling, and notified again upon termination of drilling activities. The applicant shall provide a copy of such notice to the city manager a minimum of one (1) week prior to commencing active drilling, and upon termination of drilling activities. (d) If required by the RRC, equipment for the monitoring of hydrogen sulfide (“H2S”) gas shall be used during drilling. (e) Within sixty (60) days after completion, and annually thereafter, operator shall submit to the city manager results of testing to determine the concentration of H2S produced from the well. If the results of the H2S testing proves to be 100 PPM H2S or greater, the operator is responsible for determining the 100 PPM H2S radius of exposure for each well and production facility. Wells and facilities where the concentration of H2S is equal to or greater than 100 PPM will be considered “sour.” Safety systems described herein must be approved by the fire marshal. (1) The following safety alarms and equipment are required at the well site of all wells that are capable of producing at an average rate sustained over a three-month period of at least 125 barrels of oil per day and/or 300 MCF of gas per day and for “sour” wells whose 100 PPM H2S radius of exposure is greater than fifty (50) feet: (A) H2S monitors located along the fencing; (B) Automated audible alarms to provide warnings for a substantial drop in pressure or for the presence of H2S in concentrations greater than 100 PPM; and (C) Automated valve to shut-in production from the well if a substantial drop in pressure or if the presence of H2S in concentrations greater than 100 PPM is detected. (2) The following safety alarms and equipment are required at sour tank battery facilities that are capable of producing at an average rate sustained over a three-month period of at least 125 barrels of oil per day and/or 300 MCF of gas per day and for sour wells whose 100 PPM H2S radius of exposure is greater than fifty (50) feet: (A) H2S monitors located along the fencing; (B) Automated audible alarm to provide warnings for the presence of H2S in concentrations greater 100 PPM; and (C) An electrical device capable of shutting down power to all “sour” wells producing into the battery in the event H2S in concentrations great than 100 PPM is detected.
( 1983 Code, sec. 14-169 ; Ordinance 8327 , sec. 2 (19A-20), adopted 5/28/1982 ; Ordinance 2015-O0021 adopted 3/12/2015 )
Ask a question about Lubbock law
Corpus searches the Lubbock sections it holds and shows the ones that match, with their citations. Free, no sign-in.
