§ 46-219 — Drilling fluid
Code of Ordinances, City of McAllen, Texas (through Ord. 2026-83 adopted 2026-08-24) · McAllen Code of Ordinances § 46-219
Corpus is an independent public-information project, not the official City of McAllen website. Stable reference: corpuslaw.us/code/a490e393-16e8-4532-b441-bc039c3f8179
§ 46-219: Drilling fluid.
After the setting of surface casing, as in this article provided, and drilling operations are commenced, there shall be kept at all times a mud-laden fluid for drilling purposes of a minimum weight of 8.3 pounds per gallon, and a minimum weight of 9.5 pounds per gallon when drilling in excess of 10,000 feet below the ground surface, but at no time less than such weight as will provide a hydrostatic head equivalent to the formation pressures of the horizons being drilled, and such mud-laden fluid shall be tested during drilling operations each eight hours. Just before completion or drill-stem testing operations are commenced, the mud-laden fluid shall be tested while circulating and shall be made to conform to the specifications in this section before proceeding. When coming out of the hole with the drill pipe, the drilling fluid shall be circulated until equalized and a fill-up line shall be turned into the casing to ensure a full load of fluid on the bottom of the hole at all times.
( 1966 Code, § 20-51 )