Sec. 110-478. - Backflow prevention methods and assemblies.
(a) All backflow prevention assemblies installed per this chapter shall be installed according to manufacturer's recommendations and provided with sufficient clearance to facilitate testing. (1) No assemblies are permitted in the public right-of-way, as defined in Section 90-224 of the City's Code of Ordinances. (b) If conditions that present a health hazard exist, one of the following types of backflow prevention shall be used. (1) An air gap may be used if installed per the definition of air gap in section 110-475, herein. (2) Reduced pressure principle backflow prevention assemblies may be used if installed per subsection (a) of this section and: a. The assembly is installed at a minimum of 12 inches above ground in a location that will ensure that the assembly will not be submerged; and b. Drainage is provided for any water that may be discharged through the relief valve. (3) Pressure vacuum breakers may be used if installed per subsection (a) of this section and: a. There is no actual or potential for a back-pressure condition; and b. The assembly is installed at a minimum of 12 inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. (4) Spill-resistant pressure vacuum breakers may be used if installed per subsection (a) of this section and: a. There is no actual or potential for a back-pressure condition; and b. The assembly is installed at a minimum of 12 inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. (c) If there are no conditions that present a health hazard, double check valve backflow prevention assemblies may be used to prevent backflow if the assembly is tested upon installation, and: (1) Test cocks are used for testing only. (d) Double check valve assemblies installed below ground shall meet the following installation requirements: (1) Test cocks shall be plugged, except when the double check valve is being tested; (2) Test cock plugs shall be threaded, water-tight, and made of non-ferrous material; and (3) There shall be a clearance around the entire assembly to allow space for testing and repair. (e) At a minimum, all backflow prevention assemblies shall be tested by a licensed backflow prevention assembly tester upon installation, repair, replacement, or relocation. Those backflow prevention assemblies used in irrigation systems designated as health hazards shall be tested annually. (f) An irrigation system connected to a potable water supply through a double check valve, pressure vacuum breaker, or reduced pressure principle backflow assembly, which includes an automatic master valve on the system, the automatic master valve shall be installed on the discharge side of the backflow prevention assembly. (g) The irrigator shall ensure the backflow prevention assembly is tested prior to being placed in service, and the test results shall be provided to the city and to the irrigation system's owner or owner's representative within ten business days of testing of the backflow prevention assembly.
(Ord. No. 2009-01-009, § 2, 1-20-2009; Ord. No. 2021-06-058, § 3, 6-15-2021)
Ask a question about McKinney law
Corpus searches the McKinney sections it holds and shows the ones that match, with their citations. Free, no sign-in.