For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 110-479 — Specific conditions and cross-connection control

Code of Ordinances of the City of McKinney, Texas (Codified through Ordinance No. 2022-12-145, enacted December 20, 2022 (Supp. No. 37 archive; publisher-stale)) · McKinney Code of Ordinances § 110-479

Corpus is an independent public-information project, not the official City of McKinney website. Stable reference: corpuslaw.us/code/c9e439cd-39bd-4da5-ab44-0fc814fd4f52

Sec. 110-479. - Specific conditions and cross-connection control.

(a) Before any chemical is added by any method (aspiration, injection, etc.) to an irrigation system which is connected to the potable water supply, the irrigation system shall be connected through a reduced pressure principle backflow prevention assembly or air gap. (b) Irrigation system components treated with chemical additives and connected to any potable water supply shall be connected through a reduced pressure principle backflow prevention assembly. (c) Connection of any additional water source to an irrigation system that is connected to the potable water supply can only be made if the irrigation system is connected to the potable water supply through a reduced-pressure principle backflow prevention assembly or an air gap. (d) If an irrigation system is designed or installed on a property that is served by an on-site sewage facility, as defined in V.T.C.A., Administrative Code, chapter 285 of title 30, then: (1) All irrigation piping and valves shall meet the separation distances from the on-site sewage facility system as required for a private water line in V.T.C.A., Administrative Code, title 30, § 285.91(10); (2) The irrigation system is designated a health hazard and any connections using a private or public potable water source that is not the city's potable water system must be connected to the water source through a reduced pressure principle backflow prevention assembly as defined in V.T.C.A., Administrative Code, title 30, § 344.50; and (3) Any water from the irrigation system that is applied to the surface of the area utilized by the on-site sewage facility system shall be controlled on a separate irrigation zone or zones so as to allow complete control of any irrigation to that area so that there will not be excess water that would prevent the on-site sewage facility system from operating effectively.

(Ord. No. 2009-01-009, § 2, 1-20-2009; Ord. No. 2021-06-058, § 3, 6-15-2021)

Ask a question about McKinney law

Corpus searches the McKinney sections it holds and shows the ones that match, with their citations. Free, no sign-in.