§ 110-484 — Maintenance, alteration, repair, or service of irrigation systems
Code of Ordinances of the City of McKinney, Texas (Codified through Ordinance No. 2022-12-145, enacted December 20, 2022 (Supp. No. 37 archive; publisher-stale)) · McKinney Code of Ordinances § 110-484
Corpus is an independent public-information project, not the official City of McKinney website. Stable reference: corpuslaw.us/code/4523f796-ca02-4ebf-905e-7ae4d1c80370
Sec. 110-484. - Maintenance, alteration, repair, or service of irrigation systems.
(a) All trenches and holes created during the maintenance, alteration, repair, or service of an irrigation system must be backfilled and returned to the original grade with suitable soil free of any objects that could damage the plumbing of the irrigation system. The backfill must be compacted such that a depression does not develop. (1) In the event of an alteration, an irrigation plan design may be required. (b) Colored polyvinyl chloride PVC pipe primer solvent must be used on all PVC pipes and fittings used in the maintenance, alteration, repair, or service of an irrigation system in accordance with the city's Code of Ordinances. (c) When maintenance, alteration, repair or service of an irrigation system involves excavation work at the water meter or at a point upstream of the backflow prevention assembly, an isolation valve shall be installed, if an isolation valve is not currently installed per V.T.C.A., Administrative Code, Title 30, Part 1, § 344.62(k).
(Ord. No. 2009-01-009, § 2, 1-20-2009; Ord. No. 2021-06-058, § 3, 6-15-2021)