§ 26-303 — Protection required; installation
Code of Ordinances of the City of Waco, Texas (Supp. No. 88: codified through Ordinance No. 2026-250, enacted April 21, 2026) · Waco City Code § 26-303
Corpus is an independent public-information project, not the official City of Waco website. Stable reference: corpuslaw.us/code/f0162bfa-3a4c-4cbc-b750-4cabb0b60fd3
Sec. 26-303. - Protection required; installation.
(a) All potential points of contamination shall be removed or protected by an U.L. approved assembly or device that will prevent the contamination of the potable water supply. An approved assembly or device may be used to prevent potential contamination in each of the following circumstances, but is in no way limited to the following circumstances: (1) The nature and extent of any activity on the premises, or the materials used in connection with any activity on the premises, or materials stored on the premises, could contaminate or pollute the potable water supply. (2) Premises having one or more cross connections and the cross connections are protected by an atmospheric vacuum breaker device (AVB). (3) Internal cross connections are present that are not correctable. (4) Intricate plumbing arrangements that are present which make it impractical to ascertain whether cross connections exist. (5) There is unduly restricted entry so that inspections for cross connections cannot be made with sufficient frequency to ensure that cross connections do not exist. (6) Installation of an approved backflow prevention assembly is deemed to be necessary to accomplish the purpose of these regulations in the judgment of the city. (7) An appropriate cross connection survey report form has not been filed with the city water utilities department upon request of the city. (8) A fire suppression system is connected to the city's water system. (9) All new construction if deemed necessary in the customer service inspection. The type of assembly required will be determined by the degree of hazard. (10) Any used water return system. (11) If a point-of-use assembly has not had the testing or repair done as required by this article, a premises isolation assembly will be required. (12) If it is determined that additions or alterations have been made to the plumbing system without obtaining proper permits, premises isolation may be required. (13) All multistory buildings or any building with a booster pump or elevated storage tank. (14) Retrofitting will be required on all high hazard connections and wherever else the city deems necessary to retrofit. (15) Where the potable water system is connected to any auxiliary supply. (b) The backflow prevention assembly protection that is required under this article shall be any of the duly nationally recognized and authorized backflow prevention assemblies listed in this article, or as determined by the city. Each backflow prevention assembly must have been approved by the city prior to installation. Failure to obtain such approval prior to installation of the backflow prevention assembly may result in the backflow prevention assembly failing to meet final approval by the city. The city shall determine the type and location of backflow assembly to be installed within the area served by the city's water system. (c) All backflow prevention assemblies installed after the effective date of the ordinance from which this article is derived shall be installed in a manner designed to facilitate ease of testing and inspection by the city. Any currently installed backflow prevention assemblies which are located in inaccessible locations, or where the tester is subject to physical danger, shall be relocated to approved locations following current national guideline standards. (d) Where the city requires that a property be retrofitted with backflow prevention assembly protection under this article, the city shall provide notice to the responsible party. The notice shall state the reason the backflow protection is required and state a date by which the protection must be installed. If the responsible party disagrees with the requirement, an appeal may be filed with the city manager by filing a written notice of appeal with the city secretary's office within ten business days of receiving the notice to install the backflow prevention assembly. The notice of appeal must setout in detail the specific reason(s) why the person believes the backflow protection is not needed and why the city's notice to install the protection is incorrect. The city manager, or someone designated by the city manager, shall review the appeal letter and other relevant information before issuing a decision on the appeal. That decision shall be final and not subject to further appeal. Failure to install the backflow protection assembly as required by the notice shall be a violation of this article.
(Ord. No. 2003-0527, § 1, 9-2-03; Ord. No. 2010-406, § 1, 7-20-10)
Ask a question about Waco law
Corpus searches the Waco sections it holds and shows the ones that match, with their citations. Free, no sign-in.