For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 26-316 — Responsibilities

Code of Ordinances of the City of Waco, Texas (Supp. No. 88: codified through Ordinance No. 2026-250, enacted April 21, 2026) · Waco City Code § 26-316

Corpus is an independent public-information project, not the official City of Waco website. Stable reference: corpuslaw.us/code/2752a498-7bd8-40b4-9b8c-9bf5b1560302

Sec. 26-316. - Responsibilities.

(a) Responsible party. The responsible party as defined herein shall abide by the conditions of this article and comply with the following: (1) Pay all costs associated with this article and the purchase, installation, testing and repair of backflow prevention assemblies. (2) Install and maintain all backflow prevention assemblies in accordance with this article and acceptable industry practice. (3) Annual test of all backflow prevention assemblies in nonresidential establishments, with such testing to be conducted by a certified backflow prevention assembly tester (BPAT) who is registered with the city and who provides a copy of the test results to the city. The annual test date shall be the anniversary date of the installation or one year from the date of the last testing of the device. The city shall send a notice of annual test on or about thirty days prior to the annual test date to each water account holder. Any responsible party found to be in violation of this section shall have water service terminated immediately. (4) Maintain all backflow prevention assemblies in proper working order at all times, including repair as required. (5) Maintain all backflow prevention assemblies in a manner that allows them to be tested by a method that has been approved by the regulatory authority. (6) Keep all records related to backflow prevention assembly installation, testing and repair on the premises for a minimum of three years. (b) Certified backflow prevention assembly tester. The certified backflow prevention assembly tester shall comply with the following requirements: (1) Annually register with the city and pay any registration fee. (2) Maintain testing equipment in proper working condition. Recalibration of test equipment must be performed every 12 months. (3) Maintain the design or operation characteristics of a backflow prevention assembly. (4) Ensure that devices are tested according to manufacturers recommendations and TCEQ regulations and guidance documents. (5) Enter required testing data, including test gauge serial numbers, on cross connection test forms approved by the city, which may include an online form. If a form is not filled out completely, it shall not be accepted and will be considered noncompliant. (6) Report test results to the city within seven days of testing. (7) Provide a copy of the completed test report to the responsible party and the city. (8) Maintain testing and/or repair records for a minimum of three years.

(Ord. No. 2003-0527, § 1, 9-2-03; Ord. No. 2007-286, § 1, 5-1-07; Ord. No. 2010-406, § 1, 7-20-10)

Ask a question about Waco law

Corpus searches the Waco sections it holds and shows the ones that match, with their citations. Free, no sign-in.