13-114 - Stormwater management plan.

(A) The stormwater management plan must apply the stormwater technical requirements of section 13-109 to the entire site. Individual lots in a new residential, commercial, or industrial development or sale, including those developed under subsequent owners, shall not be considered separate land-disturbing activities. Instead, the common plan, as a whole, shall be considered to be a single land-disturbing activity. The plan shall consider all sources of surface runoff and all sources of subsurface and groundwater flows converted to surface runoff. The plan shall contain maps, charts, graphs, tables, photographs, narrative descriptions, explanations, calculations, and citations to supporting references as appropriate to communicate the information required by this Article XIII. At a minimum, the stormwater management plan must contain the following: (1) Information on the type and location of stormwater discharges; information on the features to which stormwater is being discharged including surface waters, and the pre-development and post-development drainage areas; (2) Contact information including the name, address, and telephone number of the owner and the tax reference and parcel number of the property or properties affected; (3) A narrative that includes a description of current site conditions and final site conditions; (4) A general description of the proposed stormwater management facilities and a maintenance agreement and inspection schedule in accordance with section 13-109(G) to ensure that the facilities will be operated and maintained after construction is complete; (5) Information on the proposed stormwater management facilities, including: (a) The type of facilities; (b) Location, including geographic coordinates; (c) Acres treated; and (d) The surface waters into which the facility will discharge. (6) Hydrologic and hydraulic computations, including runoff characteristics. (7) Documentation and calculations verifying compliance with the water quality and water quantity requirements of section 13-109. (8) A map or maps of the site that depicts the topography of the site and includes: (a) All contributing drainage areas; (b) Existing streams, ponds, culverts, ditches, wetlands, other water bodies, and floodplains; (c) Soil types, relevant geological formations, forest cover, and other vegetative areas; (d) Current land use including existing structures, roads, and locations of known utilities and easements; (e) Sufficient information on adjoining parcels to assess the impacts of stormwater from the site on these parcels; (f) The limits of clearing and grading, and the proposed drainage patterns on the site; (g) Proposed buildings, roads, parking areas, utilities, and stormwater management facilities; and (h) Proposed land use with tabulation of the percentage of surface area to be adapted to various uses, including, but not limited to, planned locations of utilities, roads, and easements. (i) The delineation of buildable area. (B) If an operator intends to meet the water quality requirements set forth in section 13-109(E) through the use of off-site credits in accordance with section 13-109(E)(8), then a letter of availability from the off-site provider must be included. Approved off-site options must achieve the necessary reductions prior to the commencement of the applicant's land-disturbing activity except as otherwise allowed by Section 62.1-44.15:35 of the Code of Virginia. (C) If the operator intends to utilize the alternative stormwater management equivalency options in section 13-110 to meet the Alexandria water quality volume default in section 13-109(E)(6) or the additional water quality performance criteria of section 13-109(E)(8), then the operator must submit a narrative and any required calculations. (D) Site specific facilities for phased projects shall be designed for the ultimate development of the contributing project watershed based on zoning, comprehensive plans, local public facility master plans, or other similar planning documents. (E) Elements of stormwater management plans that include activities regulated under Chapter 4 of Title 54.1 of the Code of Virginia be appropriately sealed and signed by professional registered in the Commonwealth of Virginia and performed in accordance with procedures, consistent with good engineering practice, established by the director of T&ES pursuant to section 13-104(C). (F) All stormwater designs that require analysis of pressure hydraulic systems and/or inclusion and design of flow control structures must be sealed by a professional engineer registered in the Commonwealth of Virginia. (G) An as-built drawing for permanent stormwater management facilities shall be submitted to the director of T&ES in accordance with section 13-114. The as-built drawing shall be appropriately sealed and signed by a professional registered in the Commonwealth of Virginia certifying that the stormwater facilities have been constructed in accordance with the approved plan. (H) The plan shall establish a long-term schedule for inspection and maintenance of stormwater management facilities that includes all maintenance requirements and persons responsible for performing maintenance. If the designated maintenance responsibility is with a party other than the City of Alexandria, then a maintenance agreement shall be executed between the responsible party and the city in accordance with section 13-109(G).

Ask a question about Alexandria law

Corpus searches the Alexandria sections it holds and shows the ones that match, with their citations. Free, no sign-in.