For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3002 — Dimensional Standards

Code of Ordinances of the City of Montpelier, Vermont (Codified through Ordinace No. 2026-0413, adopted April 8, 2026. (Supp. No. 2, Update 1)) · Montpelier Code of Ordinances § 3002

Corpus is an independent public-information project, not the official City of Montpelier website. Stable reference: corpuslaw.us/code/b21f5eee-4186-42b7-897e-ed90e47fd1ee

Section 3002. - Dimensional Standards

3002.A Standards. Development shall conform to the dimensional standards for the applicable zoning district unless: (1) A subject parcel or structure is a nonconformity and the proposed development is in conformance with the requirements of Section 1203; (2) The applicant receives a waiver (Section 4602) or variance (Section 4603) to a dimensional standard from the Development Review Board; or (3) The proposed development will be or was approved as a planned unit development in accordance with the provisions of Chapter 340 or under a previous set of zoning regulations. 3002.B Principal Buildings. More than one principal building may be located on a parcel as follows: (1) The total amount of development on the parcel shall not exceed the maximum density or FAR allowed in the district. (2) Approval of multiple principal buildings on a parcel shall not constitute a right to subdivide or separately convey those structures. 3002.C Residential Density. Residential density shall be regulated in accordance with Section 3111 and the following: (1) Maximum residential density shall be based on a parcel's total acreage or square footage. (2) Any nonconforming parcel may be developed with one dwelling unit in accordance with these regulations irrespective of whether it has the required amount of buildable land required to meet the applicable district standard. (3) The number of dwelling units on a parcel shall not exceed the maximum density specified in each zoning district except: (a) Accessory dwelling units approved under Section 3104 shall not count as a dwelling unit for the purposes of calculating density. (b) At a minimum, any parcel served by city water and sewer may be approved for up to six dwelling units irrespective of the district density standard provided that all other applicable standards of these regulations are met. Further, any parcel served by sewer and water may be subdivided such that up to six dwelling units are on a conforming parcel irrespective of the district density provided all other applicable standards of these regulations are met. (c) Any parcel within the Design Review Overlay District or Capitol Complex shall not have a maximum residential density requirement provided that all other applicable standards of these regulations are met. 3002.D Calculating Density. Each base zoning district establishes the maximum density of development allowed on a parcel. Those standards shall be measured or calculated as described in this subsection. (1) Nonresidential Development. The density of nonresidential development and congregate living uses (see Section 3111) shall be measured as floor area ratio (FAR), which is the ratio of gross floor area, to the total parcel area as shown in Figure 3-04. (2) Residential Development. The density of residential development shall be measured in square feet of parcel area per dwelling units (sf/du). 1 acre = 43,560 square feet as shown in Figure 3-05. See also Section 3111. (3) Mixed Use Development. Proposals with both residential and non-residential development shall not exceed the necessary square footage of the combined uses. For example, an 8,500-square foot parcel in Mixed Use Residential has a maximum residential density of 1 unit per 1,500 square feet and an FAR of 1.0. If an applicant proposes three dwelling units (4,500 square feet used) then they would be allowed up to 4,000 square feet of non-residential use. (4) Off-street parking located within the footprint of a principal building shall not be included in the calculation of floor area ratio. Figure 3-01. Illustrated Parcel Dimensional Standards [image omitted; see the official code] Figure 3-02. Illustrated Setback Dimensional Standards [image omitted; see the official code] Figure 3-03. Illustrated Building Dimensional Standards [image omitted; see the official code] Figure 3-04. Floor Area Ratio (FAR) Illustrated [image omitted; see the official code] Figure 3-05. Dwelling Units per Square Foot of Parcel Area (sf/du) Illustrated [image omitted; see the official code] 3002.E Parcel Size. Parcel size shall be regulated in accordance with the following: (1) Any parcel created under these regulations shall meet the minimum parcel size requirement for the district in which it is located unless approved as part of a planned unit development in accordance with the provisions of Chapter 440. (2) Nonconforming parcels are regulated in accordance with Subsection 1203.B. (3) A parcel that has or will include land in more than one zoning district shall meet the minimum parcel size based on the proportional contribution of each zone. For example, a parcel proposed to have 2,000 square feet in MUR and 1,000 square feet in RES 6 shall have 0.667% of an MUR parcel (2,000 divided by 3,000 square feet minimum parcel size) and 0.167% of a RES 6 parcel (1,000 divided by 6,000) so combined it would have 0.833% (not enough for a legal parcel). Had that same scenario included 1,000 square feet in RES 3 rather than RES 6 it would count for 0.333% and make the total 1.0. 3002.F Street Frontage. All parcels shall front on a public or private street as specified in each zoning district and in accordance with the following: (1) An existing parcel without the minimum required frontage on public or private street must have access to such a street over an easement or right-of-way approved by the Development Review Board that is not less than 20 feet wide for single-and two-unit residential parcels and 50 feet wide for all other parcels. (2) Parcels that front on more than one street shall only be required to meet minimum frontage requirements on one street except: (a) On parcels in more than one zoning district the minimum frontage shall be maintained on at least one street in each district where the parcel has frontage. (3) All new parcels created under these regulations shall have the minimum frontage on a public or private street unless the Development Review Board: (a) Approves a parcel with less frontage as part of a planned unit development in accordance with the provisions of Chapter 340; or (b) Reduces the frontage requirement to not less than 20 feet for irregularly shaped parcels or parcels accessed by a shared driveway. 3002.G Setbacks. Buildings shall be set back from streets, property lines, and water bodies as specified in each zoning district and in accordance with the following: (1) Parcels with frontage on more than one street shall meet front setback requirements on each street, and shall meet side setback requirements on the remaining sides. (2) Accessory structures and uses may encroach into a required setback as specified in Section 3003. (3) Driveways may encroach into a required setback as specified in Section 3003, Figure 3-07. (4) To encourage a regular building pattern along a street, the Administrative Officer shall reduce the minimum front setback requirement to allow a principal building to match the average setback of the two closest principal buildings on the same side of the street. (5) Setbacks for buildings and similar structures shall be measured on a level line to the closest point on the structure to the subject property line or water body. (6) Parcels without frontage shall have no front or rear setback but shall have sides setbacks from all property lines. (7) Where an accessory structure, such as a deck or garage, is attached to a principal structure the accessory structure may encroach into the principal setback but the uses in the portion of the structure that are encroaching shall be limited to accessory uses. 3002.H Height. No structure may exceed district height limits as measured in accordance with this section and as specified below: (1) Minimum and maximum height requirements for principal structures are established for each zoning district. (2) Accessory structures shall not exceed the height requirements established in Section 3003. (3) Height limits do not apply to: (a) Belfries, spires, steeples, cupolas, domes or similar architectural features not used for human habitation; and (b) Skylights, parapet walls, cornices, chimneys, ventilators, or mechanical equipment usually located on the roof level, provided that such features are limited to the height necessary for their proper functioning. (4) Where a minimum building height is specified: (a) Buildings with a footprint of less than 6,000 square feet shall maintain that height along the entire facade and for a depth of at least 20 feet. (b) Buildings with a footprint of 6,000 square feet or more shall maintain that height along at least 30% of the facade and for a depth of at least 30 feet. (5) Height shall be measured as the vertical distance from the highest point of the structure (excluding building elements in Paragraph (3) above) to the average of the highest and lowest points where the exterior wall meets the finish grade. See Figure 3-03. 3002.I Measuring Dimensional Standards. The dimensional standards for parcels, setbacks, and buildings shall be measured as shown in Figure 3-01, Figure 3-02 and Figure 3-03. (1) Building footprint is a maximum cap for individual buildings and is not a cap of the cumulative total of all buildings. (2) Parcels without frontage shall not be required to meet frontage buildout for the district in which they are located. 3002.J Waivers. Applicants may request a waiver to dimensional standards not to exceed the maximum waiver in Figure 3-06. Applicants shall follow the process in Section 4602 and shall demonstrate the request shall meet the standards in Figure 4-02. Figure 3-06. Waiver Limitations STANDARD | MAXIMUM WAIVER Parcel Coverage | 5% or 2,000 sf more than district standard, whichever is less Setback Side | 10 ft. less than district standard, but not to less than 5 ft. Rear | 10 ft. less than district standard, but not to less than 10 ft. Building Footprint (maximum) | No maximum limit to waiver request Height (maximum) | 5 ft. Other Dimensional Standards The Development Review Board may modify any dimensional standard in these regulations by not more than 10%.

Ask a question about Montpelier law

Corpus searches the Montpelier sections it holds and shows the ones that match, with their citations. Free, no sign-in.