§ 19.240.025 — Public transportation facilities
Federal Way Revised Code (The Federal Way Revised Code is current through Ordinance 26-1052, passed September 1, 2026.) · Federal Way Revised Code § 19.240.025
Corpus is an independent public-information project, not the official City of Federal Way website. Stable reference: corpuslaw.us/code/785a3646-041f-4ef7-a9a2-aaed09b448c5
19.240.025 Public transportation facilities.
The following uses shall be permitted in the commercial enterprise (CE) zone subject to the regulations and notes set forth in this section: | USE | REGULATIONS | USE ZONE CHART DIRECTIONS: FIRST, read down to find use . . . THEN, across for REGULATIONS | Required Review Process | Minimums | Maximum Height of Structure(s) | Minimum Required Parking Spaces | SPECIAL REGULATIONS AND NOTES | Lot Size | Required Yards | Front | Side (each) | Rear | ⇩ | ⇨ | Light rail or commuter rail transit facility | Process III | None | 15 ft. | 15 ft. | 15 ft. | 50 ft. above average building elevation (AABE) See notes 2 and 5 | 500 spaces for light rail or commuter rail facilities with transit stations; 1 for each 1,000 sq. ft. of gross floor area for maintenance facilities. See notes 13, 14, 15, 16 and 17. | 1. These uses may not be located on property that adjoins a low- or medium-density residential zone. 2. If approved by the director, the height of a structure may exceed 50 ft. above average building elevation (AABE), if the increased height is necessary to accommodate the structural, equipment, or operational needs of the use. 3. No use or activity may be conducted that involves the unmitigated release of toxins, noxious gases, smoke, fumes, dust, odors, or other harmful discharges onto neighboring properties or natural systems. Discharges shall be limited to those allowed by and consistent with all applicable standards and permits regulating those emissions. 4. These uses shall cause no unmitigated recurring noise or vibration impacts perceptible from any surrounding residential zones. Mitigation shall be consistent with all applicable local, state, and federal regulations or criteria regulating noise and vibration. 5. Minor and supporting structures constructed as a functional requirement of a facility may be allowed at the same height as the primary structure, provided the director determines that the facility and any related supporting structures will not significantly impact adjacent properties. 6. The subject property must be designed so that truck parking, loading, and maneuvering areas; areas where noise generating outdoor uses and activities may occur; and vents and similar features are located as far as possible from any residential zone, conforming residential use, or natural systems. 7. No maximum lot coverage applies. Instead, the buildable area will be determined by other site development regulations, i.e., required yards, landscaping, surface water facilities, etc. 8. For regulations pertaining to outdoor use, activity and storage, refer to FWRC 19.125.170. 9. For community design guidelines that apply to the project, see Chapter 19.115 FWRC. 10. For landscaping requirements that apply to the project, see Chapter 19.125 FWRC. 11. For sign requirements that apply to the project, see Chapter 19.140 FWRC. 12. For other provisions of this chapter that may apply to the subject property, see Chapter 19.265 FWRC. 13. A reduction to the minimum required parking spaces may be allowed provided a parking study is submitted as part of the development application for city-issued land use approval to inform any decisions regarding the reduction of parking. The scope of the study may include, but is not limited to: the existing supply, utilization, and availability of publicly accessible on-street and off-street parking, projected changes to transit ridership, traffic (vehicle trip generation), and area parking availability likely to result from any interim or alternative station access and parking scenarios. The director may grant, after consultation with the city traffic engineer, a modification to the minimum number of parking spaces based upon the result of the transit station access and parking study and the approval criteria in FWRC 19.130.080(2). (Continued on next page) | Except 20 ft. along residential zones | | | | | | | For other information about parking and parking areas, see Chapter 19.130 FWRC. For details of what may exceed this height limit, see FWRC 19.110.050 et seq. For details regarding required yards, see FWRC 19.125.160 et seq. | Process I, II, III and IV are described in Chapter 19.55 FWRC, Chapter 19.60 FWRC, Chapter 19.65 FWRC, Chapter 19.70 FWRC respectively. | | | | | | | | | | | | | | | | | | | | | USE | REGULATIONS | USE ZONE CHART DIRECTIONS: FIRST, read down to find use . . . THEN, across for REGULATIONS | Required Review Process | Minimums | Maximum Height of Structure(s) | Minimum Required Parking Spaces | SPECIAL REGULATIONS AND NOTES | Lot Size | Required Yards | Front | Side (each) | Rear | ⇩ | ⇨ | | | | | | | | | 14. Provision of parking may be phased consistent with a phased parking plan included and analyzed in the transit station access and parking study. The phased parking plan must specify the percentage of required parking to be accommodated at the time of certificate of occupancy issuance for the transit facility, any applicable milestone years for provision of additional parking, and the frequency at which particular land use or transportation conditions will be evaluated for potential updates to the phased parking plan. The phased parking plan must be consistent with the findings of the access and parking study and the approval criteria in FWRC 19.130.080(2). An agreement shall be executed between the city and applicant, prior to issuance of building permits, to ensure station access and parking services are provided consistent with the phased parking plan. 15. In general, surface parking shall not be permitted for transit stations. Surface parking may be permitted if the director determines that the proposed surface parking achieves comprehensive plan and/or subarea plan goals and policies, and: a. Structured parking cannot adequately accommodate the provision of limited purpose parking such as ADA parking spaces, short term parking spaces, and electric charging stations; or b. The proposed location of surface parking is on land with low redevelopment potential, such as under a railway, where structured parking would be impractical; or c. The potential exists for the future conversion of the proposed surface parking, including parking provided in accordance with a phased parking plan under note 14, to structured parking as part of a transit-oriented development, public-private partnership, or similar means of redevelopment, and the applicant and the city have executed an agreement specifying the date when, or conditions under which, the surface parking shall be converted to structured parking if no redevelopment occurs. | | | | | | | | For other information about parking and parking areas, see Chapter 19.130 FWRC. For details of what may exceed this height limit, see FWRC 19.110.050 et seq. For details regarding required yards, see FWRC 19.125.160 et seq. | Process I, II, III and IV are described in Chapter 19.55 FWRC, Chapter 19.60 FWRC, Chapter 19.65 FWRC, Chapter 19.70 FWRC respectively. | | | | | | | | | | | | | | | | | | | |
(Ord. No. 25-1032, § 5, 11-5-25.)
Ask a question about Federal Way law
Corpus searches the Federal Way sections it holds and shows the ones that match, with their citations. Free, no sign-in.
