For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.240.040 — Hazardous waste treatment and storage – Chemical manufacturing – Gravel batch plant – Transfer station

Federal Way Revised Code (The Federal Way Revised Code is current through Ordinance 26-1052, passed September 1, 2026.) · Federal Way Revised Code § 19.240.040

Corpus is an independent public-information project, not the official City of Federal Way website. Stable reference: corpuslaw.us/code/8ab97d2e-14c8-462d-aa29-d65d54eb18d2

19.240.040 Hazardous waste treatment and storage – Chemical manufacturing – Gravel batch plant – Transfer station.

The following uses shall be permitted in the commercial enterprise (CE) zone subject to the regulations and notes set forth in this section: | USE | REGULATIONS | USE ZONE CHART DIRECTIONS: FIRST, read down to find use . . . THEN, across for REGULATIONS | Required Review Process | Minimums | Maximum Height of Structure(s) | Required Parking Spaces | SPECIAL REGULATIONS AND NOTES | Lot Size | Required Yards | Front | Side (each) | Rear | ⇩ | ⇨ | Hazardous waste treatment and storage facilities Chemical manufacturing and related products Gravel batch plant Transfer station See note 1 | Process IV | 5 acres See note 17 | 50 ft. | See note 2 | 40 ft. above average building elevation (AABE) to 55 ft. AABE See notes 3 and 4 | Chemical manufacturing and related products: 1 for each 1,000 sq. ft. of gross floor area Others: Determined on a case-by-case basis | 1. These uses may not be located on property that adjoins a low or medium density residential zone. 2. Minimum side and rear yards shall be 20 ft. along residential zones and 15 ft. along all other zones. 3. If approved by the director, the height of a structure may exceed 40 ft. above average building elevation (AABE), to a maximum of 55 ft. AABE, if all of the following criteria are met: a. The increased height is necessary to accommodate the structural, equipment, or operational needs of the use conducted in the building, and/or all ground floor spaces have a minimum floor-to-ceiling height of 13 ft. and a minimum depth of 15 ft.; b. Height complies with note 4; c. Height over 40 ft. is set back from nonresidential zones by one additional ft. for each one ft. of height over 40 ft.; and d. Rooflines are designed to avoid a predominantly flat and featureless appearance through variations in roof height, forms, angles, and materials. 4. Building height may not exceed 30 ft. AABE when located within 100 ft. of a residential zone. 5. No use or activity may be conducted that involves the unmitigated release of toxins, noxious gases, smoke, fumes, dust, odors, or other discharge on neighboring uses or natural systems. Discharges shall be limited to those allowed by and consistent with all applicable standards and permits regulating those emissions. 6. These uses shall cause no unmitigated inherent and recurring generated noise or vibration perceptible without instruments at any point along a property line, except transportation and delivery operations typically and customarily associated with the use; and provided, that such operations are not audible from a residential zone on a regular or recurring basis. Mitigation shall be consistent with all applicable local, state, and federal regulations or criteria regulating noise and vibration. 7. Any operation producing intense glare or heat shall be conducted within an enclosed building or with other effective screening in such a manner as to make such glare or heat completely imperceptible from any point along a property line. 8. Hazardous waste treatment and storage facilities must comply with state citing criteria adopted in accordance with Chapter 70.105 RCW. 9. Outdoor storage areas shall be located to the rear and/or side(s) of the principally permitted structure. 10. The subject property must be designed so that truck parking, loading, and maneuvering areas; areas where noise generating outdoor uses, storage, and activities may occur; and vents and similar features are located as far as possible from any residential zone, conforming residential use, natural systems, and public rights-of-way. 11. No maximum lot coverage applies. Instead, the buildable area will be determined by other site development regulations, i.e., required yards, landscaping, surface water facilities, etc. 12. For regulations pertaining to outdoor use, activity, and storage, refer to FWRC 19.125.170. 13. For community design guidelines that apply to the project, see Chapter 19.115 FWRC. 14. For landscaping requirements that apply to the project, see Chapter 19.125 FWRC. 15. For sign requirements that apply to the project, see Chapter 19.140 FWRC. 16. For other provisions of this title that may apply to the subject property, see Chapter 19.265 FWRC (Continued on next page) | See note 14 | | | | | | | For other information about parking and parking areas, see Chapter 19.130 FWRC. For details of what may exceed this height limit, see FWRC 19.110.050 et seq. For details regarding required yards, see FWRC 19.125.160 et seq. | Process I, II, III and IV are described in Chapter 19.55 FWRC, Chapter 19.60 FWRC, Chapter 19.65 FWRC, Chapter 19.70 FWRC respectively. | | | | | | | | | | | | | | | | | | | | | USE | REGULATIONS | USE ZONE CHART DIRECTIONS: FIRST, read down to find use . . . THEN, across for REGULATIONS | Required Review Process | Minimums | Maximum Height of Structure(s) | Required Parking Spaces | SPECIAL REGULATIONS AND NOTES | Lot Size | Required Yards | Front | Side (each) | Rear | ⇩ | ⇨ | Hazardous waste treatment and storage facilities Chemical manufacturing and related products Gravel batch plant Transfer station See note 1 | Process IV | 5 acres See note 17 | 50 ft. | See note 2 | 40 ft. above average building elevation (AABE) to 55 ft. AABE See notes 3 and 4 | Chemical manufacturing and related products: 1 for each 1,000 sq. ft. of gross floor area Others: Determined on a case-by-case basis | 17. The development must contain at least five acres; provided, however, this use may be conducted on a lot of any size if: a. The lot lines defining the lot were lawfully created prior to March 1, 1990; and b. The applicant has not owned any contiguous lot or lots since March 1, 1990. | See note 14 | | | | | | | For other information about parking and parking areas, see Chapter 19.130 FWRC. For details of what may exceed this height limit, see FWRC 19.110.050 et seq. For details regarding required yards, see FWRC 19.125.160 et seq. | Process I, II, III and IV are described in Chapter 19.55 FWRC, Chapter 19.60 FWRC, Chapter 19.65 FWRC, Chapter 19.70 FWRC respectively. | | | | | | | | | | | | | | | | | | | |

(Ord. No. 25-1032, § 7, 11-5-25; Ord. No. 12-735, § 4(Exh. A), 12-4-12; Ord. No. 07-559, § 3(Exh. A), 7-3-07. Code 2001 § 22-864.)

Ask a question about Federal Way law

Corpus searches the Federal Way sections it holds and shows the ones that match, with their citations. Free, no sign-in.