§ 2.02.590 — Amendment to IRC Table R301.2 (1) – Climatic and geographic design criteria
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.02.590
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/a8985d41-5c57-4c29-91d2-bfe9eb1cb17b
§ 2.02.590: Amendment to IRC Table R301.2 (1) – Climatic and geographic design criteria.
TABLE R301.2 (1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA Roof Snow Load | Wind Design | Seismic Design CategoryF | Subject To Damage From | Winter Design TempE | Ice Barrier Underlayment RequiredH | Flood HazardsG | Air Freezing IndexI | Mean Annual TempJ Speedd (mph) | Topographic effectsk | Special wind regionl | Wind-borne debris zonem | Weatheringa | Frost line depthb | Termitec 25 | 110 | See City published topographic maps | No | No | D1 | Moderate | 12 in | Moderate to Heavy | 29º F | No | Adoption: 3-25-1986; Flood Insurance Studies: 2017 FIRM and Puyallup Levee overtopping layer from 2007 FIRM map | 117 | 52º F For SI: 1 pound per square foot = 0.0479 kPa, 1 mile per hour = 0.447 m/s. a. | Weathering may require a higher strength concrete or grade of masonry than necessary to satisfy the structural requirements of this code. The weathering column shall be filled in with the weathering index “negligible,” “moderate” or “severe” for concrete as determined from Figure R301.2 (3). The grade of masonry units shall be determined from ASTM C 34, C 55, C 62, C 73, C 90, C 129, C 145, C 216 or C 652. b. | The frost line depth may require deeper footings than indicated in Figure R403.1 (1). The jurisdiction shall fill in the frost line depth column with the minimum depth of footing below finish grade. c. | The jurisdiction shall fill in this part of the table to indicate the need for protection depending on whether there has been a history of local subterranean termite damage. d. | The jurisdiction shall fill in this part of the table with the wind speed from the basic wind speed map [Figure R301.2 (4)A]. Wind exposure category shall be determined on a site-specific basis in accordance with Section R301.2.1.4. e. | The outdoor design dry-bulb temperature shall be in accordance with the Washington State Energy Code, as adopted and amended by the City of Tacoma in TMC Chapter 2.10. f. | The jurisdiction shall fill in this part of the table with the seismic design category determined from Section R301.2.2.1. g. | The jurisdiction shall fill in this part of the table with (a) the date of the jurisdiction’s entry into the National Flood Insurance Program (date of adoption of the first code or ordinance for management of flood hazard areas), (b) the date(s) of the Flood Insurance Study, and (c) the panel numbers and date(s) of all currently effective FIRMs and FBFMs, or other flood hazard map adopted by the community, as amended. h. | In accordance with Sections R905.1.2, R905.5.3.1, R905.7.3.1, R905.6.3.1, R905.7.3.1 and R905.8.3.1, where there has been a history of local damage from the effects of ice damming, the jurisdiction shall fill in this part of the table with “YES.” Otherwise, the jurisdiction shall fill in this part of the table with “NO.” i. | The jurisdiction shall fill in this part of the table with the 100-year return period air freezing index (BF-days) from Figure R403.3(2) or from the 100-year (99%) value on the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32° Fahrenheit)”. j. | The jurisdiction shall fill in this part of the table with the mean annual temperature from the National Climatic Data Center data table “Air Freezing Index-USA Method (Base 32° Fahrenheit)”. k. | Topographical effects shall be considered by performing a topographical analysis or using the topographical effects as published on the City of Tacoma Web Site. The appropriate KZT factor shall be applied and the analysis shall be in accordance with the provisions of the currently adopted edition of the International Building Code and/or ASCE 7.
(Repealed and reenacted by Ord. 27890 Ex. A, 2010-06-15 ; repealed and reenacted by Ord. 28155 Ex. A, 2013-06-11 ; Ord. 28363 Ex. A, 2016-06-14 ; Ord. 28410 Ex. A, 2017-02-21 ; Ord. 28957 Ex. A, 2024-03-05 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.