§ 2.02.763 — Amendment to IEBC Chapter 3 – Provisions for All Compliance Methods by addition of Section 310 Fire Protection
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.02.763
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/6cac7375-4427-4be0-ae14-efde23278132
§ 2.02.763: Amendment to IEBC Chapter 3 – Provisions for All Compliance Methods by addition of Section 310 Fire Protection.
A new section 310 Fire Protection shall be added to IEBC Chapter 3 as follows: Section 310 Fire Protection. 310.1 Group R occupancies. Where required by Sections 310.1.1, 310.1.2, 310.1.3, or 310.1.4, automatic fire sprinkler systems shall be installed within existing buildings with Group R fire areas where any of the following conditions exist: 1. | Building exceeds 5,000 square feet in area; or 2. | Building exceeds two stories in height; or 3. | Building contains five or more dwelling or sleeping units. Installation of an automatic fire sprinkler system, in accordance with Section 903.3.1.2 (NFPA 13R), may be approved in non-high-rise buildings exceeding four stories in height when approved by the fire code official and the building official. Exception: Buildings regulated by the International Residential Code. 310.1.1 Fire Damage. Throughout buildings that incur fire, water, or smoke damage where repairs include the removal and/or replacement of more than 50 percent of the ceiling finishes in more than one dwelling or sleeping unit. Exception: The fire code official is authorized to approve a work plan established by the building owner where damaged units are provided with fire sprinklers immediately and the remainder of the building is provided with fire sprinklers over a period not to exceed ten years. 310.1.2 Level I Alterations. Throughout dwelling or sleeping units where work involves the removal and/or replacement of more than 50 percent of the ceiling finishes in more than one dwelling or sleeping unit. 310.1.3 Level II Alterations. Throughout dwelling or sleeping units where work areas exceed 50 percent of the floor area of the dwelling or sleeping unit. 310.1.4 Level III Alterations and Substantial Improvements. Throughout buildings undergoing level III alterations or substantial improvements as defined in TMC Chapter 2.02.
( Ord. 28729 Ex. A, 2021-01-26 ; Ord. 28957 Ex. A, 2024-03-05 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.