§ 2.02.870 — Amendment of IEBC Appendices by addition of a new Appendix J - Requirements for Alterations to Existing Single Family, Duplex, and Townhouse Buildings and Structures
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.02.870
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/7611b4e7-a2bc-41b3-873a-a563d8a488a8
§ 2.02.870: Amendment of IEBC Appendices by addition of a new Appendix J - Requirements for Alterations to Existing Single Family, Duplex, and Townhouse Buildings and Structures.
The following new appendix chapter shall be added to the IEBC. Appendix J – Requirements for Alterations to Existing Single Family, Duplex, and Townhouse Buildings and Structures Section AJ101 Purpose and Intent The purpose of these provisions is to encourage the continued use or reuse of legally existing single family, duplex, and townhouse buildings and structures and allow alternative construction requirements from the WA State Residential Code with City of Tacoma amendments. Section AJ102 Compliance AJ102.1 General. Regardless of the category of work being performed, the work shall not cause the structure to become unsafe or adversely affect the performance of the building; shall not cause an existing mechanical or plumbing system to become unsafe, hazardous, insanitary or overloaded; and unless expressly permitted by these provisions, shall not make the building any less compliant with this code or to any previously approved alternative arrangements than it was before the work was undertaken. AJ102.3 Smoke Detectors. Regardless of the category of work, smoke detectors shall be provided where required by the WA State Residential Code with City of Tacoma amendments. AJ102.4 Replacement windows. Regardless of the category of work, where an existing window, including the sash and glazed portion, or safety glazing is replaced, the replacement window or safety glazing shall comply with the requirements of Sections AJ102.4.1 through AJ102.4.4, as applicable. AJ102.4.1 Energy Efficiency. Replacement windows shall comply with the requirements of the WSEC. AJ102.4.2 Safety glazing. Replacement glazing in hazardous locations shall comply with the safety glazing requirements of IRC Section R308. AJ102.4.3 Emergency Escape openings. Where windows are required to provide emergency escape and rescue openings, replacement windows shall be exempt from the maximum sill height requirements of IRC Section R310.2.2 and the requirements of Section IRC R310.2.1 and IRC R310.2.3 provided that the replacement window meets the following conditions: 1. | In buildings constructed prior to May 26, 1981, existing windows with a net openable area of five square feet, a minimum clear width of 22 inches, a minimum clear height of 22 inches, and a maximum sill height of 48 inches measured from the floor of the sleeping room, shall be deemed to meet the exit window requirement. 2. | Where the window frame is to be replaced, this exception shall not apply, except as necessary to fit within the rough framed opening, in which case the opening dimensions shall be maximized. (Note: If a new opening needs to be created or an existing opening needs to be enlarged to provide an exit window from a sleeping room, this exception shall not apply). 3. | Where the sill height exceeds the maximum specified, a landing with a minimum depth of 24 inches and width equal to the width of the window and frame, but not less than 36 inches, may be provided directly below the exit window within the sleeping room, provided the following are met: a. | Stairs shall be provided to the landing if its height exceeds 12 inches above the sleeping room floor. b. | The landing and stairs do not decrease the minimum required dimensions of the sleeping room below those required by this chapter and the Building Code. c. | The replacement window is not part of a change of occupancy and/or new habitable space. AJ102.4.4 Window control devices. Where window fall prevention devices complying with ASTM F2090 are not provided, window opening control devices complying with ASTM F2090 shall be installed where an existing window is replaced and where all of the following apply to the replacement window: 1. | The window is operable. 2. | The window replacement includes replacement of the sash and the frame. 3. | The top of the sill of the window opening is at a height less than 24 inches (610 mm) above the finished floor. 4. | The window will permit openings that will allow passage of a 4-inch-diameter (102 mm) sphere where the window is in its largest opened position. 5. | The vertical distance from the top of the sill of the window opening to the finished grade or other surface below, on the exterior of the building, is greater than 72 inches (1829 mm). The window opening control device, after operation to release the control device allowing the window to fully open, shall not reduce the minimum net clear opening area of the window unit. AJ102.5 Flood hazard areas. Work performed in existing buildings located in a flood hazard area as established by IRC Table R301.2(1) shall be subject to the provisions of TMC § 2.02.550 and § 2.02.560. AJ102.6 Equivalent alternatives. These provisions of this Appendix are not intended to prevent the use of any alternative material, alternative design or alternative method of construction not specifically prescribed herein, provided that any alternative has been deemed to be equivalent and its use authorized by the building official. AJ102.7 Other alternatives. Where compliance with these provisions or with this code as required by these provisions is technically infeasible or would impose disproportionate costs because of construction or dimensional difficulties, the building official shall have the authority to accept alternatives. These alternatives include materials, design features and operational features. AJ102. Features exceeding code requirements. Elements, components and systems of existing buildings with features that exceed the requirements of this code for new construction, and are not otherwise required as part of approved alternative arrangements or deemed by the building official to be required to balance other building elements not complying with this code for new construction, shall not be prevented by these provisions from being modified as long as they remain in compliance with the applicable requirements for new construction. Section AJ301 Repairs AJ301.1 Definition. Repair shall be defined as the patching, restoration or minor replacement of materials, elements, components, equipment or fixtures for the purposes of maintaining those materials, elements, components, equipment or fixtures in good or sound condition. AJ301.2 Materials. Except as otherwise required herein, work shall be done using like materials or materials permitted by this code for new construction. AJ301.2.1 Hazardous materials. Hazardous materials no longer permitted, such as asbestos and lead-based paint, shall not be used. AJ301.2.2 Plumbing materials and supplies. The following plumbing materials and supplies shall not be used: 1. | All-purpose solvent cement, unless listed for the specific application. 2. | Flexible traps and tailpieces, unless listed for the specific application. 3. | Solder having more than 0.2-percent lead in the repair of potable water systems. AJ301.3 Water closets. Where any water closet is replaced with a newly manufactured water closet, the replacement water closet shall comply with the requirements of the City of Tacoma Plumbing Code. AJ301.4 Electrical. This section deleted with a reference to comply with TMC Chapter 12.06A. Section AJ401 Renovations AJ401.1 Definition. Renovations shall be defined as the change, strengthening or addition of load-bearing elements; or the refinishing, replacement, bracing, strengthening, upgrading or extensive repair of existing materials, elements, components, equipment or fixtures. Renovation does not involve reconfiguration of spaces. Interior and exterior painting are not considered refinishing for purposes of this definition and are not renovation. AJ401.2 Materials and methods. The work shall comply with the materials and methods requirements of this code. AJ401.3 Door and window dimensions. Minor reductions in the clear opening dimensions of replacement doors and windows that result from the use of different materials shall be allowed, whether or not they are permitted by this code. AJ401.4 Interior finish. Wood paneling and textile wall coverings used as an interior finish shall comply with the flame spread requirements of IRC Section R302.9. AJ401.5 Structural. Unreinforced masonry buildings located in Seismic Design Category D2 or E shall have parapet bracing and wall anchors installed at the roofline whenever a reroofing permit is issued. Such parapet bracing and wall anchors shall be of an approved design. Section AJ501 Alterations AJ501.1 Newly constructed elements. Newly constructed elements, components and systems shall comply with the requirements of the WA State Residential Code with City of Tacoma amendments. Exceptions: 1. | Added openable windows are not required to comply with the light and ventilation requirements of IRC Section R303. AJ501.2 Nonconformities. The work shall not increase the extent of noncompliance with the requirements of Section AJ601 or create nonconformity to those requirements that did not previously exist. AJ501.3 Extensive alterations. Where the total area of all of the alteration work within each dwelling unit meets the requirements of Washington State Existing Building Code Section 604 for a Level 3 remodel, the work shall be considered to be a reconstruction and shall comply with the requirements of these provisions for reconstruction work. Exception: Alteration work which is exclusively plumbing, mechanical or electrical shall not be included in the computation of the total valuation of work. AJ501.4 Structural. The minimum design loads for the structure shall be the loads applicable at the time the building was constructed, provided that a dangerous condition is not created. Structural elements that are uncovered during the course of the alteration and that are found to be unsound or dangerous shall be made to comply with the applicable requirements of this code. AJ501.5 Electrical Equipment and wiring. This section deleted with a reference to comply with TMC Chapter 12.06A. AJ501.6 Ventilation. Reconfigured spaces intended for occupancy and spaces converted to habitable or occupiable space in any work area shall be provided with ventilation in accordance with IRC Section R303. AJ501.7 Ceiling Height. Habitable spaces created in existing basements and attics shall have ceiling heights of not less than 6 foot 8 inches (2032mm), except that the ceiling height at obstructions shall be not less than 6 foot 4 inches (1930 mm) from the basement or attic floor. Existing finished ceiling heights in non-inhabitable basements and attics shall not be reduced. AJ501.8 Stairs AJ501.8.1 Stair width. Existing basement or attic stairs and handrails not otherwise being altered or modified shall be permitted to maintain their current clear width at, above and below existing handrails. AJ501.8.2 Stair headroom. Headroom height on existing basement or attic stairs being altered or modified shall not be reduced below the existing stairway finished headroom. Existing basement or attic stairs not otherwise being altered shall be permitted to maintain the current finished headroom. AJ501.8.3 Stair landing. Landings serving existing basement or attic stairs being altered or modified shall not be reduced below the existing stairway landing depth and width. Existing basement or attic stairs not otherwise being altered shall be permitted to maintain the current landing depth and width. Section AJ601 Reconstruction AJ601.1 Stairways, handrails and guards. AJ601.1.1 Stairways. Stairways within the work area shall be provided with illumination in accordance with IRC Section R303.7. AJ601.1.2 Handrails. Every required exit stairway that has four or more risers, is part of the means of egress for any work area, and is provided with not fewer than one handrail, or in which the existing handrails are judged to be in danger of collapsing, shall be provided with handrails designed and installed in accordance with IRC Section R311 for the full length of the run of steps on not less than one side. AJ601.1.3 Guards. Every open portion of a stair, landing or balcony that is more than 30 inches (762 mm) above the floor or grade below, is part of the egress path for any work area, and does not have guards, or in which the existing guards are judged to be in danger of collapsing, shall be provided with guards designed and installed in accordance with IRC Section R312. AJ601.2 Wall and ceiling finish. The interior finish of walls and ceilings in any work area shall comply with the requirements of IRC Section R302.9. Existing interior finish materials that do not comply with those requirements shall be removed or shall be treated with an approved fire-retardant coating in accordance with the manufacturer’s instructions to secure compliance with the requirements of this section. AJ601.3 Separation walls. Where the work area is in an attached dwelling unit, walls separating dwelling units that are not continuous from the foundation to the underside of the roof sheathing shall be constructed to provide a continuous fire separation using construction materials consistent with the existing wall or complying with the requirements for new structures. Performance of work shall be required only on the side of the wall of the dwelling unit that is part of the work area. AJ601.4 Ceiling height. Habitable spaces created in existing basements or attics shall have ceiling heights of not less than 6 feet, 8 inches (2032 mm), except that the ceiling height at obstructions shall not be less than 6 feet 4 inches (1930 mm) from the basement or attic floor. Existing finished ceiling heights in non-habitable spaces in basements or attics shall not be reduced except where necessary to comply with WSEC requirements. Section AJ701 Referenced Standards ASTM F2090—17 | Specification for Window | AJ1024.3 Fall Prevention Devices with Emergency Escape (Egress) Release Mechanism | AJ1024.4 IEBC—21 | International Existing Building Code | AJ102.6
( Ord. 28729 Ex. A, 2021-01-26 ; Ord. 28957 Ex. A, 2024-03-05 )