§ 2.13.060 — Waterfront structures

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.13.060

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/97a43e69-3372-473f-bf05-07654d3128fe

§ 2.13.060: Waterfront structures.

A. General. All piers, wharves and waterfront structures as herein defined shall comply and conform to all of the requirements set forth herein. B. Protection against mechanical damage. Waterfront structures shall be designed for impact loads from vessels and floating debris. Regardless of the type of construction of the substructure, fender systems may be built of wood members with a minimum nominal dimension of four inches and a minimum nominal area of forty-eight square inches, provided the outside face of said fender system is located no more than three feet inside the outermost edge of the deck. C. Combustible substructures. 1. Piles and stiffening members. The piling and cross bracing of those portions of the substructure which are over water at any time shall be so designed to allow the passage of a six-foot wide boat for access to all points for the purpose of inspection, maintenance or repair. 2. Pier decks and supports. a. Pile caps shall consist of sawed or glue-laminated timber not less than eight-inch nominal minimum dimension and ninety-six square inches nominal cross-sectional area. b. Deck framing members shall be not less than six-inch nominal minimum dimension and seventy-two square inches nominal cross-sectional area. c. Deck planking on the deck framing shall be not less than four inches in nominal thickness and on this shall be laid a wearing surface of two-inch nominal wood sheathing, or a layer of concrete or asphalt, or other material of equivalent durability. The sheathing and deck planks shall be laid at right angles, except that in the driveways the sheathing may be laid diagonally. Exception: Pier decks without superstructures may have decks of wood decking or planking of not less than three inches nominal thickness. d. Pier decks of composite laminated wood and concrete construction shall be acceptable, provided that the wood decking or planking used shall be not less than two inches in nominal thickness and shall be pressure preservative treated in accordance with the Building Code. e. Piers and walkways which are ten feet or less in width may be constructed with caps and girders which have a minimum nominal width and depth of six-inches. Beams and other members shall have a minimum nominal width of three inches. Wood decking or planking may have a nominal thickness of two inches; and bracing may have a minimum nominal dimension of two inches. 3. Automatic fire sprinkling of combustible substructures. a. General. All combustible substructures shall be provided with a complete automatic fire sprinkler system (NFPA 13), in accordance with the IBC and IFC provisions, in the under-deck areas. b. Standards. Installation of sprinkler equipment shall be in accordance with the Building Code, Fire Code, and the Fire Code Standards. In those parts of waterfront structures where automatic fire sprinkler systems are subject to damage by floating debris, such as beneath depressed sections of pier decks, deviations from the strict application of the standards will be permitted and alternative methods of protection may be required. Where damage to sprinkler equipment by floating objects may occur, adequate provision shall be made to prevent such damage. c. Additional provisions. In addition to the standards referred to in subsection B hereof, the following provisions shall apply: i. Sprinkler systems, including fittings and hangers, used in under-deck areas shall be protected from corrosion in accordance with NFPA Standards for the Construction and Fire Protection of Marine Terminals, Piers and Wharves, current edition. ii. Water supply mains on substructures without superstructures shall be installed in under-deck space. If it is inadvisable to install mains in the under-deck space, they may be installed in the superstructure or on the deck of the substructure, with approval from the Building and Fire Officials. iii. Automatic fire sprinkler systems and supply piping subject to freezing shall be installed as dry pipe systems. iv. Automatic fire sprinkler systems installed in waterfront structures shall be maintained in accordance with the Fire Code. 4. Subdivision of combustible substructures. All substructures of combustible construction shall have the under-deck area subdivided as follows: a. Fire walls. Fire walls shall be required in combustible substructures at intervals not to exceed 450 feet in each direction. Fire walls shall also be provided at each location a fire wall occurs in a superstructure located on the substructure and shall constitute a continuation of the fire walls in the superstructure. Substructure fire walls shall be of reinforced concrete having a fire resistance of at least four hours, except that fire walls made of other approved noncombustible materials may be used, provided they are equivalent in stability and have an equivalent fire resistance. Walls shall be free of holes and shall extend from the deck down to Mean Lower Low Water. Where aprons or platforms are built along the sides of the waterfront structure, fire walls shall extend to the outside edges of such aprons or platforms. b. Fire stops. Spacing between fire walls and fire stops or between fire stops shall not exceed 150 feet. Fire stops shall fit tightly up against the deck and around any structural members or pipes that pass through the fire stop so that an effective barrier to fire and draft will be maintained. Fire stops shall be constructed of wood planking built up to a thickness of six inches and securely fastened to the supporting structure, or they may be of other construction approved by the Building Official. Fire stops shall extend from the deck down to Mean Lower Low Water. Where aprons or platforms are built along the sides of the waterfront structure, fire stops shall extend to the outside edges of such aprons or platforms. D. Fire flow required. A water supply for fire flow shall be provided in accordance with the Fire Code. E. Water supply and design of system. Water may be supplied from the municipal water system or any other water supply meeting the approval of the Fire Code Official. The minimum residual water pressure shall be 20 psi at all fire hydrants. Private water systems shall be designed and installed in accordance with the applicable requirements of referenced standards NFPA 24, Standard for the Installation of Private Fire Service Mains and their Appurtenances. F. Superstructures. 1. General. Superstructures shall comply with all the provisions of the Building and Fire Codes. Superstructures which are required by the provisions of the Building Code to be either type IA or type IB construction shall be constructed on fire-resistive substructures. Superstructures which are required by provisions of Building Code to be either IIA or IIB construction shall be constructed on noncombustible substructures. 2. Automatic fire sprinkler systems. All superstructures shall be provided with an automatic fire sprinkler system complying with the provisions of the Building Code, and the Fire Code. Area and height limits for superstructures may be increased as permitted by the Building Code for automatic fire sprinkler systems. Exception: Automatic fire sprinkler systems need not be installed in superstructures constructed on noncombustible substructures as defined herein, provided that all of the following conditions are met: i. The aggregate area of all superstructures on the substructure does not exceed 1,500 square feet, and ii. The aggregate occupant load of the superstructures, as calculated in accordance with the provisions of the Building Code, does not exceed fifteen, and iii. The occupancy classification of the superstructures on the substructure is Group B, Group F, Division 2 or Group S, Division 2 occupancies as defined in the Building Code.

( Ord. 27890 Ex. A, 2010-06-15 ; Ord. 28363 Ex. A, 2016-06-14 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.