For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.13.070 — Dry boat storage

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.13.070

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/40df4c89-bb32-4074-9289-d1a3338f1265

§ 2.13.070: Dry boat storage.

A. General. Dry boat storage shall meet all requirements of the Building and Fire Codes for a Group S, Division 1 Occupancy, and the requirements set forth within this section. B. Automatic fire sprinkler systems. When required by the building code or fire code dry boat storage shall have an automatic fire sprinkler system (NFPA 13 system) installed throughout which meets the requirements of the Building Code and Fire Code Fire Protection Standards for Marinas. C. Area. Dry boat storage shall be limited in area as set forth in the Building Code for Group S, Division 1 Occupancies, including allowing increases for yards, and automatic fire sprinkler systems, except as modified within this section: D. Construction type. Dry boat storage may be constructed of any type of construction permitted by the Building Code for a group S, division 1 occupancy, except an automatic fire sprinkler system shall not be substituted for one-hour fire resistive construction. In non-rated types of construction, floors in multistory dry boat storage buildings shall be of one-hour fire-resistive construction, or heavy timber construction as defined in the Building Code. E. Height. Dry boat storage shall be limited in height in accordance with the provisions of the Building Code. F. Rack storage of boats. Rack storage shall meet the following conditions: 1. Rack boat storage buildings or structures shall be a maximum of one story in height and constructed entirely of noncombustible construction conforming to the requirements for type IA, IB, IIA or IIB construction for a group S, division 1 occupancy. Buildings or structures housing rack boat storage shall be fully protected with an automatic fire sprinkler system (NFPA 13 system) meeting the requirements of the Building Code. The allowable area for the building may be increased by open areas around the building in accordance with the building code, and for the automatic fire sprinkler system. The automatic fire sprinkler system shall not be used to increase the building height beyond the one story maximum height limitation, but may be used to increase the height of the building in feet in accordance with the building code. 2. Interior longitudinal walls shall not be permitted. Interior noncombustible transverse walls which are a minimum of two-hour fire-resistive fire walls shall be permitted for the purposes of dividing the rack boat storage buildings into two or more structures for purposes of area limitation. No other transverse walls shall be permitted. Except for the first level of the rack storage, there shall be no floors and no permanent catwalks. 3. Rack structures shall be limited to a maximum of three levels of boat storage. An automatic fire sprinkler system shall be installed within all boat storage racks in accordance with the building and fire codes and reference standard for the installation of sprinkler systems and the NFPA Fire Protection Standard for Marinas, so as to provide coverage of all stored boats. Exception: Additional levels of boat storage within a rack may be permitted, provided technical assistance in the form of a technical opinion and report will be required in accordance with the Fire Code to evaluate the level of safety of the proposed design. However, when this provision is used, the maximum number of in rack storage racks shall not exceed five. 4. A Class I standpipe system designed and installed with the Fire Code reference standard N.F.P.A. Standard for Installation of Standpipe and Hose systems shall be provided for all rack boat storage structures. 5. Rack structures shall be designed to support the weight of all the boats plus the weight of water any two boats in a vertical storage column may collect in the event that the automatic fire sprinkler systems are triggered. 6. Boats shall be prepared for storage in racked storage by: a. Disconnecting the battery while the boat is in storage. An adequately sized power disconnect switch shall be provided for this purpose. b. The bilge drain plug shall be removed. c. A water impermeable boat cover shall be installed to cover all open parts of the boat while being stored in the rack. The cover when installed shall be taut and shall not have sags or other concavities which will collect water. (Note: the cover is to prevent filling the boats with water in the event that the automatic fire sprinkler systems are triggered.)

( Ord. 27890 Ex. A, 2010-06-15 ; Ord. 28363 Ex. A, 2016-06-14 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.