§ 2.13.080 — Marinas
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.13.080
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/77ec1bf2-54fd-4834-98c6-3ad2d2d89b49
§ 2.13.080: Marinas.
A. General. Marinas, because of their character, present unique problems in providing access for fire-fighting purposes, for providing water supply, and for providing exiting. In order to mitigate these problems all Marinas shall conform to the provisions of this section and the Fire Code. B. Float system layout. 1. Water access aisles: a. Where vessels are moored to a main float system on either side of the maneuvering aisle such that the berths are not parallel to the maneuvering aisle, the clear distance between the limit lines for obstructions, measured perpendicular to the maneuvering aisle, shall be a minimum of 1.25 times the length of the longest vessel served but not less than forty (40) feet. Vessels in berths between finger floats may extend a maximum of five (5) feet beyond the ends of the finger floats into the access aisle, thereby establishing the limit line for obstructions. The extension into the access aisle shall be measured to the furthest extension of the vessel which shall include but not be limited to bowsprits, overhangs, swimming platforms and dinghies. Where vessels are housed in boat houses, the boat houses may extend to the limit line for obstructions. The maneuvering aisle shall be established by assuming a center line between or along the rows of boat houses. The limit lines for obstructions shall be established at points on both sides of the assumed center line of not less than five-eighths (5/8) of the longest boat house along the aisle, but not less than twenty feet. The centerline shall be relatively straight down the aisle length, with no changes of direction by less than a 40 foot radius, except at the ends of aisles where additional maneuvering room is provided. Where vessels are housed in boat houses, and the water access aisles exceed 300 feet in length the limit lines for obstructions shall be not less than 40 feet on each side of the assumed center line for the entire length of the aisle. Exception: Where water access aisles exceed 300 feet, the Fire Chief may allow narrower water access aisles where site conditions require or permit narrower water access aisles, and alternate fireboat access is possible. b. Where vessels are moored parallel to and on one side of a water access aisle, the water access aisle widths shall be not less than forty (40) feet, plus 1.25 times the beam of the largest vessel expected to be moored at the facility. If vessels are moored parallel to and on both sides of an access aisle, the access aisle shall be not less than forty (40) feet, plus 2.5 times the beam of the largest vessel expected to be moored at the facility. c. Water access routes and entries for vessels to a marina facility, shall be not less than forty (40) feet in width. 2. Fire department access passages. Access passages along uncovered finger floats, through covered boat storage sheds or between boat houses shall be provided between the water access aisles and the main floats, at intervals not to exceed two-hundred (200) feet. When vessels are moored on both sides of main floats the access passages shall be staggered by one-hundred (100) feet from one side to the other. Access Passages shall extend to the limit line for obstructions. Fire Department access passages shall have a minimum unobstructed width of forty-eight (48) inches. Toe rails or curbs a minimum of five (5) inches in height shall be provided along both sides of access passages. The clear distance between the toe rails shall be not less than forty-one (41) inches. 3. Main float length. No portion of a main float shall exceed one-thousand (1000) feet in distance from the bottom of a gangway providing access to the shore or to a waterfront structure. The position of the bottom of the gangway shall be measured at Mean High Water (+5.00 Feet NOAA Datum). For fuel dispensers on a float system see the Fire Code provisions for marine service stations. 4. Main float widths. Main floats shall provide an unobstructed pathway with minimum dimensions of forty-four (44) inches in width by seven (7) feet in height, which shall be maintained the length of the main float at all times. 5. Finger float widths. Finger floats shall be not less than thirty-six (36) inches in width. 6. Gangway width. Gangways shall have a minimum clear width of forty-four (44) inches. Handrails may extend a maximum of 3.5 inches into the required width on each side. 7. Gangway slope. Gangways which are ramps shall not slope more than one (1) vertical to two and one-half (2.5) horizontal when tide is at Mean Lower Low Water (-6.33 Feet NOAA Datum). Cleats and a nonslip surface shall be provided on ramp gangways. Gangways constructed with self-leveling stairs shall provide treads runs of not less than eleven (11) inches nor more than eighteen (18) inches, and risers of not less than four (4) inches nor more than seven (7) inches. An approved nonslip surface shall be applied to all stair treads. 8. Gangway handrails and guardrails. Guardrails shall be provided on both sides of gangways. Guardrails shall be a minimum of forty-two (42) inches in height measured perpendicular to the slope of the gangway surface. Guardrails shall be provided with intermediate bars or a pattern spaced to prevent a sphere four (4) inches in diameter from passing through. Handrails shall be provided on both sides of the gangway and shall be placed thirty-four (34) inches measured perpendicular to the slope of the gangway surface. The grip portion of the handrail shall be of a graspable shape not less than one and one-half (1.5) inches nor more than two (2) inches in diameter, and there shall be a space of one and one-half (1.5) inches between the backside of the handrail and the guardrail. C. Covered moorage size and spacing limitations. Covered moorage shall be considered to be of two types, enclosed and open. Enclosed covered moorage are boat houses which are enclosed on three or more sides. Open covered moorage are roof structures which are generally supported on posts or frames, and which are open on two or more sides. The area of covered moorages shall be subject to the limitations set forth in the following table: Allowable Areas For Covered Moorages2, 3, 4, 5, 6, 7 Building Code Type of Construction | Allowable Single Boat House Area1 | Allowable Area for Boat Covers and Area of Combined Boat Houses7 VB | 3000 sq-ft | 9000 sq-ft IIB | 3000 sq-ft | 17,500 sq-ft Footnotes: 1 Sidewalls for all new boat houses, for all new enclosed boat covers and all boat houses relocated from other locations outside the marina in question, shall be sheathed with corrosion resistant steel. Aluminum, wood and plastic siding materials shall be prohibited. 2 Provide smoke venting for all new structures and for all structures relocated from other locations outside of the marina in question in accordance with the Fire Code. 3 Clearances for calculated area increases shall be in accordance with the building code. 4 Unroofed areas to separate adjacent covered moorage areas on the same float system shall be a minimum of sixteen (16) feet or 33 percent of the longest finger float whichever is greater. Unroofed areas may be used for moorage. 5 The areas listed in the table, including those for single boat houses may be tripled if the boat house or the covered boat moorages are provided throughout with an automatic fire sprinkler system. The area of individual boat houses may be tripled if the boat house alone is fire sprinklered, but no area increase is permitted for the combined boat house areas unless all the boat houses and open boat covers are fire sprinklered. 6 Draft curtains shall be provided in accordance with the Fire Code; however, if draft stops are constructed of sheet metal, the sheet metal shall be steel, with rust protection. 7 The areas of open boat covers and the combined area of boat houses may be increased for yards or open spaces in accordance with the provisions of the Building Code. The area of individual boat houses shall not be increased for yards or open spaces. D. Structural design criteria. 1. Vertical design loads. a. Float systems including the finger floats shall be designed to support all dead loads plus a superimposed live load of twenty (20) pounds per square-foot over their entire walking surface. b. Covers or boat houses supported by a float system shall be designed to support all dead loads plus a snow load of twenty (20) pounds per square-foot. Float systems supporting covers or boat houses shall be designed to support the dead loads and snow loads contributed by the covers or boat houses plus the live and dead loads prescribed in item A above. Snow sliding off upper roofs onto floats or lower roofs shall be taken into consideration in the design. c. Float systems, including the finger floats shall be designed to withstand a minimum concentrated load at any location on the walking surfaces of five-hundred (500) pounds, without causing any of the elements of the float system to tilt more than six (6) degrees from level (10.5% Slope). The concentrated load is to be located at any thirty (30) by thirty (30) inch square on the walking surface and shall be applied simultaneously with the uniform load. Snow loading on covers or boat houses may be reduced to ten (10) pounds per square-foot while applying the concentrated loads. d. Gangways shall be designed to support a minimum of fifty (50) pounds per square-foot live load over their horizontal projected area at Mean High Water, along with all dead loads. Gangways shall also be designed to support a concentrated load of one-thousand pounds (1000) pounds on any thirty (30) by thirty (30) inch square on the gangway; however the concentrated load need not be applied simultaneously with the required uniform live load. The reaction of the gangway under full load shall not cause the main float to tilt out of level by more than six (6) degrees (10.5% slope). 2. Wind design loads. The float systems and their anchorages shall be designed to withstand wind as prescribed in the building code; however the design wind load need not exceed twenty (20) pounds per square-foot. The wind load shall be applied to the projected areas of the covers, boat houses and moored vessels. It shall be assumed that all berths are occupied. Covers and boat house structures shall be designed to withstand wind uplift loads as prescribed in the Building Code. 3. Stresses induced by waves. a. Vertical loads. Float systems shall be designed to carry all dead loads, plus 20 PSF live load on all walking surfaces, plus 20 PSF snow load on all covers supported by the float system, over a span of not less than ten (10) feet. The float system shall be able to carry these loads over the design spans in both the transverse and longitudinal directions. The design spans shall be located along the floats system for analysis to produce the greatest stresses along the float system. b. Lateral loads. In addition to the wind loads, float systems and their anchorage systems shall be designed to resist lateral loads induced by wave action. Unless supported by a dynamic analysis, those float systems and their anchorage systems protected by breakwaters or otherwise sheltered from wind and waves or are subject to waves with heights of two (2) feet or less, shall be designed to withstand lateral loads of not less than one-half (1/2) gravity. Those float systems exposed to open water, or subject to waves in excess of two (2) feet in height shall be designed to withstand lateral loads of not less than full gravity. The calculation of lateral forces shall be based on the total dead load of the float system and all structures supported by the float system. 4. Special loads. Guardrail and Handrail Assemblies: Guardrail and Handrail assemblies shall be designed to withstand a load of not less than twenty (20) pounds per lineal foot applied horizontally at the top most rail of the guardrail and handrail assembly. 5. Special considerations. Provision shall be made to prevent individual boat houses from "hammering" into each other. E. Construction materials: 1. Flotation materials: a. Timber logs and other wood flotation shall not be used within float systems in Marinas. Exception: Wood flotation may be approved by the Building Official when unusual circumstances warrant its use. b. Foam flotation shall meet the following minimum specifications: i. Physical properties: Density: Not less than 0.9 pounds per cubic foot. (ASTM D-1622) Compressive Strength: Not less than 10 psi. (ASTM D-1621) Flexural Strength: Not less than 25 psi ultimate strength. (ASTM C-203) Moisture Absorption: The maximum water absorption shall be not greater than four (4) percent when tested by the immersion method. (ASTM C-272) ii. Chemical properties. Hydrocarbon Resistance: Foam flotation to be used within flotation systems shall be resistant to the chemical reaction with hydrocarbon fuels and lubricants or protected by an approved encapsulation system. iii. Protection from mechanical damage. Foam flotation systems shall be protected from direct contact by vessels, floating debris and foot traffic by wood or concrete decking and wood or concrete fender or skirt systems. c. Steel or metal flotation systems are not permitted in salt water applications but may be used in fresh water marinas. Exception: The Building Official may permit steel or metal flotation systems in applications which are temporary. Approvals shall be limited to a maximum of one-year. An additional year may be approved if, on inspection after the first year, it is determined that the flotation system is in good condition. d. Concrete pontoon floats shall be constructed using an approved concrete design mix of not less than six (6) sacks of cement per cubic yard, and a 28 day ultimate strength of not less than 4000 pounds per square inch. The concrete mix shall meet ACI specifications for use within a salt water environment and to provide corrosion resistance for the structural, temperature and shrinkage reinforcement within the concrete pontoons. Concrete pontoon reinforcing shall be epoxy coated. The interior cavity of the concrete pontoons shall be filled with foam flotation meeting the requirements of this code. e. Fueling floats. All floats used for fuel docks shall have a Portland cement concrete or other approved nonabsorbent surface impervious to fuel spillage. 2. Decking, fender, and float encasement materials. Decking, fender and float encasement materials shall be sized to withstand the design loads, both vertical and horizontal as prescribed by this code. Materials shall be compatible with the marine environment. Wood materials shall be pressure treated meeting AWPA standards for the species, product, preservative, and end use. Concrete materials shall have a minimum compressive stress of 4000 psi at 28 days. Concrete mixes shall have a minimum of six (6) sacks of cement per cubic yard. Metal materials shall be galvanized, painted or otherwise coated to retard corrosion, and if necessary cathodically protected. 3. Boat house and boat cover framing. Boat house and boat cover framing shall be sized to meet the design criteria prescribed in this code, for vertical, horizontal and uplift loads. Materials shall meet the requirements for decking, fenders and float encasement as prescribed in item No. 2 above for a minimum distance of three (3) feet above the float system. From three (3) feet above the float system, framing materials shall comply with the Building Code. 4. Boat house and boat shed roof and wall coverings. Boat house and boat shed roof and wall coverings shall be galvanized or painted steel. Approved wood-based structural panels manufactured with exterior glue may be used in boat houses, under the steel roof or wall covering, to provide vertical and/or lateral strength. Such structural panels shall not be directly exposed to the weather, and shall not be used in locations which become submerged or are subject to water splash. Exception: Approved wood-based structural panels manufactured with exterior glue may be used in open boat covers for the construction of gusset plates. F. Draft curtains. Draft curtains shall be provided in accordance with the Fire Code; however, if draft stops are constructed of sheet metal, the sheet metal shall be steel, with rust protection.
( Ord. 27890 , 2010-06-15 ; Ord. 28363 Ex. A, 2016-06-14 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.