§ 2.19.050 — Clearing and grading requirements
Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.19.050
Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/d466a00f-1a60-4ffe-b69f-13637fa63b95
§ 2.19.050: Clearing and grading requirements.
A. Application requirements. 1. General. The plans shall contain the location of the work, limiting dimensions of the proposed clearing, including any setbacks, and the location of any existing improvements or structures where work is to be performed, and the location of any existing improvements or structures within 50 feet of the proposed clearing area. The plans shall also contain provisions for the preservation of natural land and water features, vegetation, drainage, and other indigenous features of the site. Clearing associated with Engineered Grading work or within geohazard areas, or as determined by the Director of Planning and Development Services, or designee, shall require a plan prepared by a civil engineer and/or approved hydrologist or forest management expert. 2. Clearing. Clearing shall be accomplished in a manner that will not create, or contribute to, flooding, erosion, or increased turbidity, siltation, or other forms of pollution. Clearing shall be conducted so as to expose the smallest practical area of soil to erosion for the least possible time, consistent with the construction schedule. Provisions shall be made for interim erosion control measures. Clearing shall be accomplished in a manner that will not create, or contribute to, landslides, accelerated soil creep, settlement, and subsidence on the subject property and/or adjoining properties. 3. Site cleanup. Vegetative material from the cleared site shall be removed or chipped in an approved manner, within 60 days from the completion of the operation. Chipped material deposited on an interim basis shall be protected from becoming a fire hazard. 4. Grading. The grading plan shall show the existing grade and finished grade in contour intervals of sufficient clarity to indicate the nature and extent of the work and show in detail that it complies with the requirements of this code. The plans shall show the existing grade on adjoining properties, including public rights-of-way, for a distance as required by the City from the proposed grading area, but not less than is necessary to provide sufficient detail to identify how grade changes will conform to the requirements of this code. The plan shall also identify all drainage courses and surface water flow to and from the site, both existing and proposed. B. Earthwork. 1. Excavations. Unless otherwise recommended in an approved soils engineering report, excavations shall conform to the provisions of this section. The slope of excavated surfaces shall be no steeper than is safe for the intended use, and shall be no steeper than two horizontal to one vertical (50 percent). Steeper slopes, if specifically addressed in the soils engineering report, may be authorized by the City. EXCEPTIONS: An excavated surface may be at a slope of 1.5 horizontal to 1 vertical (67 percent), provided that all of the following are met: a. It does not support structures or surcharges. b. It is protected against erosion. c. It is no more than 8 feet in height. d. It is approved by the Building Official. 2. Fills. a. General. Unless otherwise recommended in an approved soils engineering report, fills shall conform to the provisions of this section. EXCEPTION: These provisions may be waived by the Building Official for minor fills not intended to support structures, sanitary or storm sewers, sidewalks, and private or public roads. b. Surface preparation. The ground surface shall be prepared to receive fill by removing vegetation, topsoil, and other unsuitable materials, and scarifying the ground to provide a bond with the fill material. c. Benches and keys. Where existing grade is at a slope steeper than 5 horizontal to 1 vertical (20 percent) and the depth of the fill exceeds 5 feet, benching and keying shall be provided. Benches shall be essentially level and a minimum of 5 feet in width. Keys shall be at the toe of the fill slope in undisturbed native soil and be placed beneath the fill. They shall be at least 10 feet in width and 2 feet in depth. (See Figure 2.19.1) d. Fill material. Fill material shall not include organic, frozen, or other deleterious materials. Except as approved by the Building Official, no rock, broken concrete, or similar irreducible material greater than 12 inches in any dimension shall be included in fills. [image] Figure 2.19.1 e. Compaction. All fills supporting buildings and other structures shall be compacted to a minimum of 90 percent Modified Proctor in accordance with ASTM D1557, or as specified by the civil engineer of record. Lifts shall not exceed 12 inches in depth. Special inspection to verify compaction is required for fills supporting buildings or other structures. The number and frequency of field tests shall be specified by the civil engineer of record. Compaction in existing or future City rights of way shall be in accordance with the requirements of the City of Tacoma Public Works Department Standards and the most current City of Tacoma Design Manual. f. Maximum slope. The slope of fills shall be no steeper than is safe for the intended use. Fill slopes shall not be steeper than two horizontal to one vertical, unless justified by a soils engineering report. 3. Setbacks. a. General. Cut and fill slopes shall be set back from site boundaries in accordance with this section. Setback dimensions shall be horizontal distances measured perpendicular to the site boundary. Setback dimensions shall be as shown in Figure 2.19.2, unless alternate setbacks are approved by the Building Official and/or a soils engineering report. The Building Official may require greater setbacks to protect public property. b. Slope setbacks. The top of slopes shall not be graded closer to the face of the footing than one-third of the vertical height of the slope with a maximum of 40 feet (Figure 2.19.2). The setback may need to be increased for any required interceptor drains. The toe of slopes shall be graded not closer to the face of the structure than one-half the height of the slope, with a maximum of 15 feet. c. Special provisions. Where a graded slope is to be located near the site boundary and the adjacent off-site property is developed, special precautions shall be incorporated into the work as the Building Official and/or soil engineering report deem necessary to protect the adjoining property from damage as a result of such grading. These precautions may include, but are not limited to: (1) Additional setbacks. (2) Provisions for retaining walls or similar structures. (3) Terracing. (4) Erosion protection of slopes, and other provisions for the control of surface water. [image] Figure 2.19.2Foundation Clearances from Slopes 4. Terracing and associated drainage. a. General. Unless otherwise recommended by a civil engineer, terracing and associated drainage facilities shall conform to the provisions of this section: EXCEPTION: Terracing and associated drainage facilities are not required where the ground slope is not steeper than 3 horizontal to 1 vertical (33 percent), and provided surface water runoff and erosion are controlled. b. Terraces. Terraces at least 6 feet in width shall be established at not more than 30-foot vertical intervals on all cut or fill slopes to control surface drainage and debris, except that where only one terrace is required, it shall be at mid-height. For cut or fill slopes greater than 60 feet and up to 120 feet in vertical height, one terrace at approximately mid-height shall be 12 feet in width. Terrace widths and spacing for cut and fill slopes greater than 120 feet in height shall be designed by a civil engineer and approved by the Building Official. Terraces shall be backsloped and cross sloped to capture surface water and to direct it to swales, ditches, and/or interceptor drains. Suitable access shall be provided to permit proper cleaning and maintenance.
( Ord. 28701 Ex. A, 2020-11-17 ; Ord. 28797 Ex. A, 2021-12-14 )
Ask a question about Tacoma law
Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.