For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 2.21.610 — Egress requirements

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.21.610

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/9a9532d5-52f2-4413-b740-3bef55a1f228

§ 2.21.610: Egress requirements.

A. Exit location and exit access. The shelter shall be located on a level of exit discharge and must be clearly defined in the shelter facility plan submitted with the Temporary Shelter Permit application. Exception: The shelter may be located no more than one level above or below a level of exit discharge if the building is equipped throughout with an automatic fire sprinkler system. Exit access travel distance shall not exceed 250 feet for a building equipped throughout with an automatic fire sprinkler system and 200 feet without a sprinkler system. Common path of egress travel shall not exceed 75 feet unless approved by the Building Official and Fire Code Official. B. Number of exits. Exits within the temporary shelter shall comply with the following requirements: 1. All stories within a temporary shelter area shall have a minimum of two means of egress (exits) from each story. 2. Shelter sleeping rooms on a level of exit discharge with less than 10 residents shall have at least one exit and, where the sleeping rooms are provided as separate rooms, from the rest of the story, shall have at least one window qualifying as an emergency escape and rescue window. Exception: Buildings equipped with a fire sprinkler system are not required to have an emergency escape and rescue window. 3. Shelter sleeping rooms that are located on stories above or below the level of exit discharge shall have two exits from any room. The exits serving the room shall be separated by a distance equal to at least one-third of the longest diagonal distance of the room. C. Emergency lighting. 1. Exits and exit access doors shall be marked with an exit sign readily visible from any direction of egress travel. In addition, the path of travel to exits and within exits shall be marked by readily visible exit signs to clearly indicate the direction of egress travel where the direction of egress travel is not immediately visible to the occupant. 2. Exit signs shall be illuminated at all times by either electrically powered self-luminous, or photo luminescent signs listed and labeled in accordance with UL 924. Backup power in the form of batteries, unit equipment, or an onsite generator is required for exit signs that are electrically powered. 3. Every exit sign and directional exit sign shall have lettering and illumination in conformance with the most recently adopted City of Tacoma Building Code requirements. 4. Exit paths shall be unobstructed and exit doors shall be maintained to be readily openable at all times without the use of a key or special knowledge or effort. 5. Sleeping rooms that exit only to a hallway shall be provided with at least one working flashlight when occupied. 6. The path of exit travel shall be illuminated at a minimum of one-foot candle.

( Ord. 28507 Ex. A, 2018-05-01 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.