§ 2.21.630 — Smoke and fire protection

Municipal Code, City of Tacoma, Washington (Tacoma Municipal Code current through legislation adopted 2026-09-30 (eCode360 publication TA6977, scraped 2026-11-18)) · Tacoma Municipal Code § 2.21.630

Corpus is an independent public-information project, not the official City of Tacoma website. Stable reference: corpuslaw.us/code/1a84df7c-1d7e-48ba-a17a-a1f4a4c61bf3

§ 2.21.630: Smoke and fire protection.

The Shelter Operations Plan shall address the response plan to smoke and carbon monoxide alarms or other life safety equipment, and the maintenance of such equipment. Specific requirements for this equipment are provided in this section. A. Smoke and carbon monoxide alarms. All shelter sleeping areas shall be provided with either interconnected smoke alarms or a complete smoke detection system. Smoke alarms may be battery operated, and can be interconnected wirelessly. Each room used for sleeping and any hallways or other spaces between the sleeping room and the shelter egress shall be provided with an approved smoke alarm and carbon monoxide alarm. Other shelter spaces shall be provided with smoke alarms that are also interconnected with sleeping area smoke alarms. Smoke alarms shall be spaced using NFPA 72 spacing requirements for smoke detectors. Exception: Where sleeping areas are not separated and are located in one room, smoke alarms and carbon monoxide alarms are not required to be interconnected. Spacing of alarms shall be provided per NFPA 72 spacing requirements for smoke detectors, with a maximum of 30 foot by 30 foot per smoke alarm. B. Fire watch. Buildings that are not equipped throughout with an automatic sprinkler system and monitored fire alarm system with occupant notification shall be required to have a Fire Watch. The Fire Watch position must be served by a trained staff person who has a high degree of familiarity with the building layout and emergency egress routes in the event of an emergency, and has the authority to conduct an emergency evacuation of the building in the event of an emergency. The Fire Watch must be maintained at all times when the facility is housing residents, and shall maintain a daily log indicating that staff has inspected the premises for fire on 30 minute intervals. If approved by the Building Official and Fire Code Official, or their designees, the Fire Watch may also serve a dual role as the Point of Contact person for shelter staffing. C. Fire extinguishers. A 2A10BC fire extinguisher shall be located within five feet of each required exit, within five feet of any appliances used to warm food, and within 75 feet of all other areas within the shelter. Additional extinguishers may be required for specific hazards as outlined in the International Fire Code Section 906.

( Ord. 28507 Ex. A, 2018-05-01 )

Ask a question about Tacoma law

Corpus searches the Tacoma sections it holds and shows the ones that match, with their citations. Free, no sign-in.