§ 16.22 — Light, Ventilation and Occupancy Limitations
Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Code of General Ordinances § 16.22
Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/8bb44e66-c024-49a2-b943-5294bb6edace
16.22. - Light, Ventilation and Occupancy Limitations.
A. General. 1. Scope. The provisions of this Section shall provide the minimum requirements and standards for Light, Ventilation and Occupancy limitations for Structures. 2. Responsibility. The Responsible Person shall provide and maintain Light, Ventilation and Occupancy limitations in compliance with this Section. 3. Prohibition. A Person shall not occupy, or permit another Person to occupy any Structure that does not comply with the requirements of this Section. 4. Alternative Devices. In lieu of the means for natural Light and Ventilation herein prescribed, artificial Light or mechanical Ventilation complying with the City Building Code shall be permitted. B. Light. 1. Habitable Spaces. Every Habitable Space shall have at least one (1) window of a size required by the Wisconsin Administrative Code Chapters SPS 320-325 facing directly to the outdoors or to a court. The minimum total window pane areas for every Habitable Space shall be eight (8) percent of the floor area of such room. Wherever walls or other portions of a Structure face a window of any room and such obstructions are located less than three (3) feet from the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court, and shall not be included as contributing to the required minimum total window area for the room. Where natural Light for rooms or spaces without exterior window pane areas is Provided through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight (8) percent of the floor area of the interior room or space, but not less than twenty-five (25) square feet. The exterior window pane area shall be based on the total floor area being served. 2. Common Hall and Stairway Spaces. a. Two- to Four-Family Dwellings. Public pathways and stairways in Buildings accommodating two (2), three (3) or four (4) families shall be Provided with convenient Light switches controlling a system for adequate lighting, which may be turned on when needed. b. Five (5) or More Families. Public pathways and stairways in Buildings accommodating more than four (4) families, accommodating more than thirty (30) Persons, or accommodating transients shall be lighted at all times with adequate Light. c. Where one (1) or more lighting fixtures(s) are installed for interior stairways, there shall be a wall switch at each floor level, and landing level that includes an entryway, to control the lighting outlet(s) where the stairway between floor levels has six (6) risers or more. An exception is allowed in hallways, in stairways and at outdoor entrances, remote, central or automatic control of lighting shall be permitted. 3. Adequate lighting for safe movement through the Basement shall be Provided with a Light switch at the main entrance. 4. Other Spaces. For attics, underfloor spaces, utility rooms, and Basements, at least one (1) lighting fixture containing a switch or controlled by a wall switch shall be installed where these spaces are used for storage or contain equipment which may require periodic servicing. At least one (1) point of control shall be a wall switch at the usual point of entry to these spaces. Lighting shall be Provided at or near equipment which may require periodic servicing. C. Ventilation. 1. Habitable Spaces. Every Habitable Space shall have at least one (1) openable window. The total Openable Area of the window in every room shall be equal to at least forty-five (45) percent of the minimum window paned area required in this Code. Where rooms and spaces without openings to the outdoors are ventilated through an adjoining room, the unobstructed opening to the adjoining room shall be at least eight (8) percent of the floor area of the interior room or space, but not less than twenty-five (25) square feet. The Ventilation openings to the outdoors shall be based on a total floor area being ventilated. 2. Bathrooms. Every Bathroom shall comply with the Ventilation requirements for Habitable Spaces as required by this Code, except that a window shall not be required in such spaces as are equipped with a mechanical Ventilation system. Air exhausted by a mechanical Ventilation system from a Bathroom shall discharge directly to the outdoors and shall not be recirculated. 3. Clothes Dryer Venting Systems. Clothes dryer venting systems shall be independent of all other systems and shall be vented directly outside or in accordance with the manufacturer's instructions. D. Occupancy Limitations. 1. Privacy. Dwelling Units and rooming units of Lodging Houses shall be arranged to provide privacy and be separate from other adjoining spaces. 2. Minimum Room Widths. A habitable room, other than a kitchen, shall not be less than seven (7) feet in length or width. Kitchens shall have a clear passageway of not less than three (3) feet between counter fronts and appliances or counter fronts and walls. 3. Minimum Ceiling Heights. Habitable spaces, hallways, corridors, laundry areas, Bathrooms, toilet rooms and habitable Basement areas shall have a clear ceiling height of not less than seven (7) feet. Rooms occupied exclusively for sleeping, study or similar purposes may have a sloped ceiling over all or part of the room, with a clear ceiling height of at least seven (7) feet over not less than one-third (⅓) of the required minimum floor area. In calculating the floor area of such rooms, only those portions of the floor area with a clear ceiling height of five (5) feet or more shall be included. 4. Bedroom Requirements. Every Bedroom shall comply with the following requirements: a. Area For Sleeping Purposes. Every Bedroom occupied by one (1) Occupant shall contain at least seventy (70) square feet of floor area, and every Bedroom occupied by more than one (1) Occupant shall contain at least fifty (50) square feet of floor area for each Occupant thereof. b. Access From Bedrooms. Bedrooms, except for in Dwelling Units that contain only one (1) Bedroom, shall not constitute the only means of access to other Bedrooms or Habitable Spaces and shall not serve as the only means of egress from other Habitable Spaces. c. Bathroom Accessibility. Every Bedroom shall have access to at least one (1) Bathroom without passing through another Bedroom. Every Bedroom in a Dwelling Unit shall have access to at least one (1) Bathroom located in the same story as the Bedroom or an adjacent story. d. Kitchens and Nonhabitable Spaces. Kitchens and nonhabitable spaces shall not be used for sleeping purposes. e. Basement Bedrooms. No Basement space shall be used as a Bedroom unless: (1) The floor and walls are impervious to leakage of underground and surface runoff water and are insulated against dampness. (2) The total windowpane area in each room that is capable of admitting natural Light must be at least the area required in paragraph 16.22 B.1. (3) The total of openable window area in each room must be at least the minimum required in paragraph 16.22 C.1, except where there is supplied some other device affording adequate Ventilation and approved by the Code Official. (4) The room meets all the requirements of this Code and the requirements of the Wisconsin Administrative Code Chapters SPS 20-25, specifically including egress window requirements. 5. Minimum Area Requirements. Dwelling Units shall not be occupied by more Occupants than permitted by the minimum area requirements specified in the following Table 16.22.D.5. MINIMUM AREA REQUIREMENTS TABLE 16.22.D.5 MINIMUM AREA IN SQUARE FEET SPACE | 1—2 Occupants | 3—5 Occupants | 6 or More Occupants Living Room | No Requirements | 120 s.f. | 150 s.f. Dining Room | No Requirements | 80 s.f. | 100 s.f. Kitchen | 50 s.f. | 50 s.f. | 60 s.f. Bedrooms | 70 s.f. for 1 Person; 50 s.f. for each Person where more than 1 Person a. Sleeping Area. The minimum Occupancy area required by Table 16.22.D.5. shall not be included as a sleeping area in determining the minimum Occupancy area for sleeping purposes. b. Combined Spaces. Combined living room and dining room spaces shall comply with the requirements of Table 16.22.D.5. if the total area is equal to that required for separate rooms and if the space is located so as to function as a combination living room/dining room. 6. Efficiency Unit. Nothing in this Section shall prohibit the use of an Efficiency Dwelling Unit meeting the following requirements: a. An Efficiency Dwelling Unit occupied by not more than two (2) Occupants shall have a clear floor area of not less than two hundred twenty (220) square feet. An Efficiency Dwelling Unit occupied by three (3) Occupants shall have a clear floor area of not less than three hundred twenty (320) square feet. These required areas shall be exclusive of the areas required by subparagraphs b. and c.; b. Having a kitchen sink, space and hookups for cooking appliances and refrigeration facilities, each having a clear working space of not less than thirty (30) inches in front. Light and Ventilation conforming to this Code shall be Provided; c. Having a separate Bathroom containing a toilet, lavatory, and bathtub or shower; and d. Having no more than three (3) Occupants.
(Ord. No. 18-24, § 1, 5-6-2024)
Ask a question about Kenosha law
Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.