16.25. - Fire Safety Requirements.
A. General. 1. Scope. The provisions of this Section shall provide the minimum requirements and standards for fire safety relating to Structures and Premises, including fire safety facilities and equipment to be Provided. 2. Enforcement. a. Code Official. The Code Official shall be responsible for enforcing the requirements of this Code in one- and two-family Dwellings and in the individual units located in multifamily units containing three (3) or more units. b. Fire Prevention Bureau. The Fire Prevention Bureau shall be responsible for enforcing the City's fire safety requirements in accordance with Chapter III of the Code of General Ordinances. 3. Responsibility. The Responsible Person of the Premises shall provide and maintain fire safety facilities and equipment in compliance with this Section. 4. Prohibition. A Person shall not occupy or permit another Person to occupy any Premises that does not comply with the requirements of this Section. B. Means of Egress. 1. Number of Exits. Every Dwelling, Dwelling unit and Lodging Room shall have direct access to at least two (2) accessible unobstructed means of egress or stairways above the first floor, one (1) of which must lead to an open public street, alley, or court connected to a street. 2. Types of Egress. Exterior stairways, Egress Windows or exit platforms, or a combination thereof, will be permitted as second exits for Dwellings and Dwelling Units constructed prior to January 1, 1985 (date of modification to the Wisconsin Administrative Code Chapters SPS 320-325) if approved by the Code Official. Platforms or stairways shall terminate at a point not more than ten (10) feet above the grade directly below the lowest platform for Buildings containing three (3) or more units and fifteen (15) feet above the grade directly below the lowest platform for one (1) and two (2) unit Dwellings. Platforms shall have a minimum size of three (3) feet by four (4) feet. All stairways and platforms shall be protected with handrails and guardrails as specified in the Wisconsin Administrative Code. Egress exits not meeting the above criteria may be approved by the Code Official. 3. Exit Capacity. The capacity of the exits serving a floor shall be sufficient for the Occupant load thereof as determined by the Wisconsin Administrative Code Chapters SPS 320-325 and 350-364. 4. Arrangement. Exits from Dwellings, Dwelling Units, and lodging units shall not lead through other such units, or through Bathrooms. 5. Security. Bars, grilles or screens placed over emergency escape windows shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the window. C. Unobstructed Passageways. 1. Stairways, passageways, doors, windows, fire escapes or other means of egress shall be kept open and unobstructed. Exterior exits shall be unobstructed. 2. Hazardous Material. Combustible, flammable, explosive or other hazardous materials, such as paints, volatile oils and cleaning fluids, or combustible rubbish, such as wastepaper, boxes and rags, shall not be accumulated or stored unless such storage complies with the applicable requirements of the Building Code and the Fire Prevention Code. D. Fuel Oil Tanks. Abandoned fuel oil tanks shall be referred to the Fire Prevention Bureau for review and disposition. E. Fire Doors. All required fire doors shall be maintained in good working order, including all hardware necessary for the proper operation thereof. Fire doors shall not be held open by door stops, wedges and other unapproved hold-open devices. F. Fire Protection Systems. 1. Smoke Detectors. The Responsible Person of a Dwelling, Dwelling Unit and Lodging Room shall install a functional Smoke Detector as follows: a. One- and Two-Family Dwellings Constructed Prior to June 1, 1980. (1) In the Basement of the Dwelling. (2) On each floor, except the attic or storage area of each Dwelling Unit. b. One- and Two-Family Dwellings Constructed After June 1, 1980. (1) In the Basement. (2) On each floor level, except the attic or storage area of each Dwelling Unit. (3) For floor levels containing a sleeping area, Smoke Detectors shall be installed adjacent to the sleeping area. If a floor level contains two (2) or more sleeping areas remote from each other, each sleeping area shall be Provided with an adjacent Smoke Detector. (4) Smoke detectors shall be continuously powered by the electrical service in the Dwelling and shall be interconnected. (5) For family Dwelling Units with split levels or open adjacent levels with less than one (1) full story separation between levels, one (1) Smoke Detector on the upper level shall suffice for an adjacent lower level, including Basements. c. Apartment Buildings, Condominiums, Townhouses Exceeding Sixty (60) Feet (or Six (6) Stories), and All Lodging Houses. (1) In the Basement. (2) At the head of every open stairway. (3) At the door on each floor level leading to every enclosed stairway. (4) Either in each sleeping area of each Dwelling Unit or elsewhere in the unit within six (6) feet of each sleeping area and not within a kitchen. (5) All Smoke Detectors in stairways, corridors and other public places in the Building shall be directly and permanently wired to a proper unswitched circuit. d. Multifamily Dwelling Constructed After April 1, 1995; Additions to Multifamily Dwelling Constructed After April 1, 1995; Conversion to Multifamily Dwelling After April 1, 1995. (1) In the Basement. (2) At the head of every open stairway. (3) At the door on each floor level leading to every enclosed stairway. (4) Either in each sleeping area of each Dwelling Unit or elsewhere in the Unit within six (6) feet of each sleeping area, but not within a kitchen. (5) All Smoke Detectors shall be directly and permanently wired to a proper unswitched circuit and be Provided with a backup source of power. e. Installation. All Smoke Detectors shall be installed in accordance with the Building Code and the manufacturer's instruction. When actuated, the smoke detectors shall provide an alarm suitable to warn the occupants within the individual room or dwelling unit. f. Tampering Prohibited. It shall be a violation of this Code for any Person to remove or tamper with the Smoke Detector. g. Maintenance. The Responsible Person shall maintain all Smoke Detectors in the common areas of all Residential Buildings. The Occupant of a Dwelling or Dwelling Unit shall maintain any Smoke Detector in that Dwelling or Dwelling Unit, except that if any Occupant who is not the Responsible Person, or a State, County, City, Village or Town officer, agent or employee charged under State Statute or municipal ordinance with powers or duties involving inspection of real or personal property, gives written notice to the Responsible Person that the Smoke Detector is not functional, the Responsible Person shall provide within twenty-four (24) hours after receipt of that notice, any maintenance necessary to make that Smoke Detector functional. 2. Carbon Monoxide Detectors. A. Installation. 1. The Responsible Person shall install a minimum of one (1) carbon monoxide detector in a single family Building, and, if applicable, it shall be in place at the time of possession by any tenants. 2. The Responsible Person shall install a carbon monoxide detector in all of the following places: a. In the Basement of the Building if the Basement has a fuel-burning appliance. b. Within fifteen (15) feet of each sleeping area of a unit that has a fuel-bring appliance. c. Within fifteen (15) feet of each sleeping area of a unit that is immediately adjacent to a unit that has a fuel-burning appliance. d. In each room that has a fuel-burning appliance and that is not used as a sleeping area, a carbon monoxide detector shall be installed under this subdivision not more than seventy-five (75) feet from the fuel-burning appliance. e. In each hallway leading from a unit that has a fuel-burning appliance, in a location that is within seventy-five (75) feet from the unit, except that, if there is no electrical outlet within this distance, the Responsible Person shall lace the carbon monoxide detector at the closest available electrical outlet in the hallway. 3. Any carbon monoxide detector that bears an Underwriters Laboratories, Inc., listing mark or similar mark from an independent product safety certification organization satisfies the requirement of this subsection. 4. The Responsible Person shall install every carbon monoxide detector required by this subsection according to the directions and specifications of the manufacturer of carbon monoxide detectors. B. Maintenance Requirements. 1. The Responsible Person of a Residential Building shall reasonably maintain every carbon monoxide detector in the Residential Building in the manner specified in the instructions for the carbon monoxide detector. 2. An Occupant of a unit in a Residential Building may give the Responsible Person of the Residential Building written notice that a carbon monoxide detector in the Residential Building is not functional or has been removed by a Person other than the Occupant. The Responsible Person of the Residential Building shall repair or replace the nonfunctional or missing carbon monoxide detector within twenty-four (24) hours after receipt of the notice. 3. The Responsible Person of a Residential Building is not liable for damages resulting from any of the following: a. A false alarm from a carbon monoxide detector if the carbon monoxide detector was reasonably maintained by the Responsible Person of the Residential Building. b. The failure of a carbon monoxide detector to operate properly if that failure was the result of tampering with, or removal or destruction of, the carbon monoxide detector by a Person other than the Responsible Person or the result of a faulty detector that was reasonably maintained by the Owner as required under paragraph a. 4. Tampering Prohibited. No Person may tamper with, remove, destroy, disconnect, or remove batteries from an installed carbon monoxide detector, except in the course of inspection, maintenance, or replacement of the detector. 5. Exceptions. Carbon Monoxide detectors are not required if the Residential Building does not have an attached garage and any of the following applies: a. The Residential Building does not have any fuel-burning appliances. b. All of the fuel-burning appliances in the Residential Building have sealed combustion units that are covered by the manufacturer's warranty against defects.
(Ord. No. 18-24, § 1, 5-6-2024)
Ask a question about Kenosha law
Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.