§ 16.24 — Mechanical and Electrical Facilities and Equipment

Code of General Ordinances of the City of Kenosha, Wisconsin (Codified through Ordinance No. 33-26, adopted September 9, 2026. (Supp. No. 11, Update 2)) · Kenosha Code of General Ordinances § 16.24

Corpus is an independent public-information project, not the official City of Kenosha website. Stable reference: corpuslaw.us/code/b349c0df-fba7-4103-b4b6-71260bf274f6

16.24. - Mechanical and Electrical Facilities and Equipment.

A. General. 1. Responsibility. The Responsible Person of the Structure shall provide and maintain mechanical and electrical facilities and equipment in compliance with this Section. 2. Prohibition. A Person shall not occupy or permit another Person to occupy any Structure that does not comply with the requirements of this Code. No Responsible Person shall cause any mechanical or electrical service, facility or equipment which is required under this Code to be removed from, shut off from or discontinued from any occupied Dwelling, Dwelling Unit or Lodging Room rented or occupied by him/her, except for temporary interruption as may be necessary while actual repairs are in process, or during such temporary emergencies when discontinuance of service is approved by the Code Official. B. Heating Facilities and Equipment. 1. Facilities and Equipment Required. Heating facilities and equipment shall be Provided in Structures as required by this Section. 2. Residential Occupancies. Dwellings and Dwelling Units shall be Provided with heating facilities and equipment capable of maintaining a room temperature of sixty-seven (67) degrees Fahrenheit in all habitable rooms, Bathrooms and toilet rooms. 3. Heat Supply. Every Responsible Person for any Structure who Rents one (1) or more Dwelling Units, either expressed or implied, shall furnish to the Occupants thereof, a permanently attached heating system capable of maintaining a temperature of not less than sixty-seven (67) degrees Fahrenheit in all habitable rooms and Bathrooms. Unless the lease provides otherwise, the Owner of the property is responsible to provide heat. Portable space heaters may not be used as the main heat supply. Underwriters' Laboratories listed portable space heaters may be permitted as a temporary source of heat only while the main heat supply is being repaired. 4. Central Heating System Requirements. Every central heating system shall comply with the Wisconsin Administrative Code Chapters SPS 323, 363 and 364 when applicable. It shall also comply with the following requirements: a. The central heating system shall be in Good Repair and Good Working Condition. b. Every heat duct, steampipe and hot water pipe shall be free of leaks and shall function so that an adequate amount of heat is delivered where intended. c. Every seal between the sections of a warm air furnace shall be tight, so noxious gases will not escape into heat ducts. 5. Permanently Attached Space Heaters. Every permanently attached space heater shall comply with the Wisconsin Administrative Code Chapters SPS 323, 363 and 364, when applicable, and with all of the following requirements: a. No space heater burning solid, liquid or gaseous fuels shall be a portable type. b. Every space heater burning solid, liquid or gaseous fuels shall be properly vented in accordance with manufacturer's instructions. c. Every coal burning or oil burning space heater shall have a fire resistant panel beneath it. d. The location of space heaters, the insulation of walls and ceilings close to such heaters and the construction, installation and guarding of smokepipes and walls or ceilings through which they go shall meet the requirements of applicable State Law and City Ordinances. C. Fuel Burning Appliances. 1. Definition. Fuel Burning Appliances shall mean and include nonelectrical stoves and food preparation devices, water heaters and fireplaces, and all components and accessories therefor, which burn natural gas, LP gas, wood or other combustible materials. 2. Installation and Maintenance. All fuel-burning appliances shall be properly installed and maintained in Good Repair, in Good Working Condition, and shall be capable of performing the intended function. 3. Prohibited Use. Cooking appliances shall not be used to meet the heating requirements of this Code. 4. Venting. All fuel burning appliances shall be connected to an approved chimney or vent, except for appliances which are approved by the manufacturer for unvented operation. 5. Clearances. All manufacturer required clearances for fuel burning appliances shall be maintained. 6. Safety Controls. All safety controls for fuel burning appliances shall be maintained in Good Repair, Good Working Condition and be capable of performing the intended function. 7. Combustion Air. A supply of air for complete combustion of the fuel and for Ventilation of the space containing the fuel burning appliance shall be Provided. 8. Energy Conservation Devices. Devices intended to reduce fuel consumption by attachment to a fuel-burning appliance, to the fuel supply line thereto, or to the vent outlet or vent piping therefrom, shall not be installed unless labeled by the manufacturer for such purpose and the installation is specifically approved by the manufacturer. D. Electrical Facilities. 1. Facilities Required. Every occupied Structure shall be Provided with an electrical system in compliance with the requirements of this Section. 2. Service. Every Dwelling and Dwelling Unit shall be served by a main service that is not less than sixty (60) amperes, three (3) wires and protected with fuses or circuit breakers. 3. Electrical System Hazards. Where it is found that the electrical system in a Structure constitutes a hazard to the Occupants or the Structure by reason of inadequate service, improper fusing, insufficient outlets, improper wiring or installation, deterioration or damage, or for similar reasons, the Code Official shall require the defects to be corrected to eliminate the hazard. E. Electrical Equipment. All electrical equipment, wiring and appliances shall be properly installed and maintained in Good Repair, in Good Working Condition and be capable of performing the intended function. No loose cords or loose extension lines in excess of six (6) feet in length shall be permitted and no ceiling or wall fixture shall be used for supply and power to equipment other than that for which they are designed.

(Ord. No. 18-24, § 1, 5-6-2024)

Ask a question about Kenosha law

Corpus searches the Kenosha sections it holds and shows the ones that match, with their citations. Free, no sign-in.