§ 103-328 — Minimum standards for basic equipment, lighting, ventilation, heating and electrical service
Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-328
Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/e30d07ed-2658-4f34-9160-447b4efa1c58
Sec. 103-328. - Minimum standards for basic equipment, lighting, ventilation, heating and electrical service.
(a) The purpose of this division is to establish minimum standards for basic equipment, lighting, ventilation, and electrical services for all residential buildings and parts thereof and to obtain the public and private benefits accruing from the provision of such services. A suitable environment for safe and healthy living is encouraged by adequate water and sanitary facilities, proper storage and disposal of garbage and other refuse, safe means of egress, provision of light, air, heat, and electrical service. (b) No person shall occupy as owner or let to another for occupancy any space in a residential building for the purpose of living, sleeping, cooking or eating therein which does not comply with the following requirements: (1) Potable water from an approved source shall be available at all times in residential buildings, at a pressure which is adequate for normal human requirements. All sources of domestic water shall meet the State of Wisconsin standards for potability. The domestic water supply system of the building shall be connected to such approved source and shall not be subject to contamination. (2) All potable water supply piping and fittings, for each plumbing fixture shall be installed in such a manner that backflow or back siphonage cannot occur. Backflow connections shall not be permitted between the piping system carrying potable water and any piping system or plumbing equipment carrying nonpotable water or water-borne waste. All drinking fountains provided in any building or on any premises shall comply with the requirements of the State of Wisconsin Plumbing Code. (3) Every dwelling unit shall contain a kitchen sink in good working condition and properly connected to a water and sewer system approved by the Fire Department - Division of Fire Prevention and Building Safety. (4) Every dwelling unit shall contain a nonhabitable room which affords privacy to a person within said room and which is equipped with a flush water closet and a lavatory basin in good working condition and properly connected to a water and sewer system approved by the Fire Department - Division of Fire Prevention and Building Safety. (5) Every dwelling unit shall contain, within a room which affords privacy to a person within said room, a bathtub or shower in good working condition and properly connected to a water and sewer system approved by the Fire Department - Division of Fire Prevention and Building Safety. (6) Every toilet and bathroom shall have at least 14 square feet of floor space. This minimum figure may be adjusted upward by the Fire Department - Division of Fire Prevention and Building Safety if additional or above-standard size fixtures are to be installed. (7) Every kitchen sink, lavatory basin, and bathtub or shower required under the provisions of this section shall be properly connected with hot and cold water lines which provide pressure which is adequate for normal human requirements. (8) Every dwelling unit shall be supplied with adequate refuse storage facilities, the type and location of which are approved by the Fire Department - Division of Fire Prevention and Building Safety and comply with section 36-69. (9) Every dwelling unit shall have adequate garbage disposal faculties or garbage storage containers, the type and location of which are approved by the Fire Department - Division of Fire Prevention and Building Safety and comply with section 36-69. (10) Every dwelling shall have supplied water heating facilities which are properly installed, are maintained in safe and good working condition, are properly connected with the hot water lines required under the provisions of this section and are capable of heating water to such a temperature as to permit an adequate amount of water to be drawn at every required kitchen sink, lavatory basin, bathtub, or shower at a temperature of not less than 110 degrees Fahrenheit. Such supplied water heating facilities shall be capable of meeting the requirements of this subsection when the dwelling or dwelling unit heating facilities required under the provisions of section 103-331 are not in operation. (11) Each dwelling or other building used for human habitation or other buildings where human beings are in need of sewer and water facilities, which is located upon or adjacent to any street in and along which sewer and water pipes have been laid, or which has reasonable access to sewer or water mains, shall be connected with the sewer and water systems; except that when a private well is in compliance with Wis. Admin. Code ch. NR 812, the Wisconsin Well Code, is adequate and safe, this supply may be continued in operation until such time as it is in need of repair. If the owner fails to comply with a notice in writing served upon said owner, agent or tenant requiring the owner to connect with the public sewer or water within 30 days, the Board of Public Works may cause a connection to be made and necessary fixtures to be installed and the cost shall be assessed as a special tax against the property. The owner may file within 30 days a claim of inability to pay the amount in one sum, and ask that the levy be made in five equal installments with interest at six percent, installments to be paid annually with the regular tax. The owners of all premises used for human habitation which are not located upon or adjacent to any street in and along which sewer and water pipes have been laid, or which have no reasonable access to sewer or water mains, must provide a septic tank seepage pit system therefor, constructed and maintained in accordance with the requirements of this Code. All other privy vaults, cesspools, and dry wells shall be removed or abated, and the use thereof discontinued. (12) Exits shall be provided as follows: a. Every dwelling unit shall have access to two or more safe, unobstructed means of egress with minimum headroom of six feet four inches, leading directly to safe and open space at ground level, or as otherwise provided by Wis. Admin. Code chs. SPS 321 and 366. b. Where the second floor is the lowest floor level in a dwelling unit, a flat roof deck or platform will be permitted as a minimum for a secondary exit. The platform shall be provided with at least a 36-inch high, but no more than a 46-inch high guardrail above the platform floor. If the platform is serving more than one dwelling unit, except in a duplex situation, the guardrail shall be at least 42 inches above the platform floor. Existing guardrails on platforms shall be structurally sound, safe and constructed with at least two uniformly spaced intermediate rails. Guardrails installed or replaced after January 1, 2006, shall be constructed to prevent the through-passage of a sphere with a diameter of four inches or larger. The platform depending on the dwelling unit it serves, shall comply with regulations contained in Wis. Admin. Code chs. SPS 321 and 366. The floor of the platform or roof edge may not exceed an elevation of 15 feet above the grade below. (13) Handrails and guardrails are required as follows: a. Stairs with more than three risers shall be provided with at least one structurally sound and safe handrail for the full length of the stairs, including on the open side of the stair where at least one intermediate rail at aid height or equivalent shall be provided. Handrails on the open side of the stair shall be constructed to prevent the through-passage of a sphere with a diameter of four inches or larger and shall comply with Wis. Admin. Code chs. SPS 321 and 366. b. All openings between floors and open sides of landings, platforms, balconies or porches that are more than 24 inches above grade or a floor shall be protected with guardrails. c. Guardrails shall be safe, structurally sound, extend to a height of at least 42 inches above the floor and, if unenclosed, shall have intermediate rails or balusters as specified in Wis. Admin. Code chs. SPS 321 and 366. Protective guardrails within or serving one dwelling unit or duplex shall extend to a height of at least 36 inches above the floor.
(Code 1980, § 8.01(C); Ord. No. 4911, § I(attch.), 1-14-2016)
Ask a question about La Crosse law
Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.