§ 103-329 — Light, ventilation and heating minimum standards
Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-329
Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/81f268a4-58bc-47a2-8309-2645a83d3164
Sec. 103-329. - Light, ventilation and heating minimum standards.
No person shall occupy as owner-occupant or let to another for occupancy any dwelling or dwelling unit, for the purpose of living therein, which does not comply with the following requirements: (1) Every living, sleeping, or bathroom shall have available natural light and ventilation complying with Wis. Admin. Code SPS 321.05 as dictated by the occupancy of the building. Existing light and ventilation conditions which do not comply with State standards may remain in use with the approval of the Fire Department - Division of Fire Prevention and Building Safety. (2) Every habitable room shall have at least one window or skylight facing directly to the outdoors. The minimum total window area, measured between stops, for every habitable room shall he eight percent of the floor area of such room. (3) Whenever walls or other portions of structures face a window or any such room and such light-obstruction structures are located less than three feet from the window and extend to a level above that of the ceiling of the room, such a window shall not be deemed to face directly to the outdoors and shall not be included as contributing to the required minimum total window area. Whenever the only window in a room is a skylight-type window in the top of such rooms, the total window area of such skylight shall equal at least fifteen percent of the total floor area of such room. (4) Every habitable room shall have at least one window or skylight which can easily be opened, or such other device as will adequately ventilate the room. The net openable window or exterior door area in every habitable room shall be at least 3.5 percent of the net floor area of the habitable room, except where there is supplied some other device affording adequate ventilation and approved by the Fire Department - Division of Fire Prevention and Building Safety. (5) Every bathroom and water closet compartment shall comply with the light and ventilation requirements for habitable rooms contained in subsection (1) of this section, except that no window or skylight shall be required in adequately ventilated bathrooms and water closet compartments equipped with a ventilation system in working condition which is approved by the Fire Department - Division of Fire Prevention and Building Safety. (6) All doors required for ventilation and all windows shall be protected with insect screen equivalent to not less than 16 wire mesh installed to prevent the entrance of flies, mosquitoes and other insects, annually during May before June 1 and maintained until storm windows are installed in autumn. (7) All exterior windows shall have storm windows installed or maintained to prevent excessive drafts and heat loss no earlier than October 25, but no later than November 15 annually.
(Code 1980, § 8.01(D); Ord. No. 4911, § I(attch.), 1-14-2016)
Ask a question about La Crosse law
Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.