§ 103-330 — Electrical
Municipal Code of the City of La Crosse, Wisconsin (Codified through Ordinance No. 5384, enacted August 13, 2026. (Supp. No. 43)) · La Crosse Municipal Code § 103-330
Corpus is an independent public-information project, not the official City of La Crosse website. Stable reference: corpuslaw.us/code/b9007297-b6a3-49a2-8bb2-330bb29b2ce8
Sec. 103-330. - Electrical.
Every dwelling unit shall be supplied with electrical service, wiring, outlets and fixtures which shall be properly installed and shall be maintained in good and safe working condition. The following requirements shall be applicable to all dwelling units: (1) Every bathroom, bedroom, water closet compartment, kitchen, dining room, living room, laundry room, furnace room, hall, stairway and exterior entrance shall have at least one approved wall or ceiling light fixture capable of providing no less than five footcandles at floor level in the center of the room. A switched outlet may be substituted for a light fixture in bedrooms, living rooms and dining rooms. (2) A minimum number of separate duplex-type receptacle outlets, separated by a reasonable distance, shall be provided as follows: a. Kitchen and living room: Three each room with at least one outlet serving the food preparation area. b. Bedrooms: One duplex outlet per occupant of the bedroom, with a minimum of two outlets per bedroom. c. Every bathroom and water closet compartment shall have one approved ground fault type duplex outlet. d. Every habitable room not listed in subsection (2)a and (2)b of this section shall have at least two separate duplex convenience outlets; or one such duplex convenience outlet and one supplied ceiling or wall light fixture. e. All duplex outlets that may be used for electric appliances that are not major electric appliances, and are located within six feet of sinks, lavatories, showers or bathtubs, shall be an approved ground fault type. (3) Branch circuits shall be protected by circuit breakers, or by S-type or equivalent safety type, tamper proof fuses not to exceed the amp capacity of the smallest wire in the circuit. (4) No duplex electric convenience outlet shall serve more than two fixtures or appliances. (5) Fixed appliances exceeding ⅛ hp. or 300 watts rating shall not be connected to general purpose branch circuits. Convenience outlets are to be located to prevent use of extension cords (NBC 400-8). All cords and temporary wiring not in compliance with NEC Article 400-A, and all exposed abandoned wiring shall be removed. (6) Switches or equivalent devices for turning on any light required in a room or passageway shall be located so as to conveniently control the area to be lighted. (7) Public halls and stairways in multiple dwellings shall be adequately lighted by natural or electric light at all times, so as to provide in all parts thereof at least 2½ footcandles of light at the tread or floor level. Halls and stairways in structures containing not more than three dwelling units may be supplied with conveniently located switches, controlling the lighting system, which may be turned on when needed. Other occupancies require full-time or automatic time-switched lighting. In single, duplex, or multiple dwellings when dwelling unit or lodging room doors open to the outside a minimum of 2½ footcandles of illumination at the locks are required. Parking lots for more than three cars shall be lighted to provide at least 0.25 footcandle on any surface in the lot with an average illumination level of at least 0.75 footcandle, except that the outer four feet of the periphery of the parking lot will not be subject to the 0.25 footcandle minimum. Outdoor light fixtures shall be designed and installed to eliminate spill light and glare into adjacent properties. (8) Outdoor light fixtures attached to any residential structure or accessory structure in all residential zoning districts shall be properly installed, maintained and shall be directed and/or shielded so that there will be no objectionable direct light emissions. Illumination shall be limited to 0.5 footcandles at a height of five feet above the ground at the subject property line. The provisions of this subsection shall not apply to lights directly aimed skyward at United States flags and provided that said lights do not cause objectionable direct light emissions onto neighboring property.
(Code 1980, § 8.01(E))
Ask a question about La Crosse law
Corpus searches the La Crosse sections it holds and shows the ones that match, with their citations. Free, no sign-in.