§ 18-286 — Boards supporting wood strip flooring
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-286
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/dcdc5ecd-570b-4352-b28c-7fe54dba95b2
Sec. 18-286. - Boards supporting wood strip flooring.
Boards supporting wood strip flooring shall comply with the following specifications: (1) Minimum thickness, one inch (nominal) for joists spaced a maximum of 16 inches on centers. (2) Maximum width shall be eight inches. (3) Subfloor may be installed diagonal to or at right angles to joists. If installed at right angles to joists, finish floor shall be installed across subfloor. (4) Boards shall have ends cut parallel to and over center of joists with not more than two adjacent boards breaking joints on the same joist except at ends and at openings. End matched T and G boards may break joints between joists provided two end joints do not occur in the same joist space in adjoining boards and each board bears on at least two joists. (5) Where a header joist is not used, install blocking between ends of joists at wall for nailing ends of diagonal subfloor. Blocking shall also be provided where subfloor is cut away for plumbing and heating. (6) Provide at least one-half-inch clearance between subflooring and masonry or concrete walls.
(Code 1973, § 30.32.010)