§ 18-290 — Plank subfloor
Municipal Code of the City of Racine, Wisconsin (Codified through Ordinance No. 0082-26, adopted March 3, 2026. (Supp. No. 108)) · Racine Municipal Code § 18-290
Corpus is an independent public-information project, not the official City of Racine website. Stable reference: corpuslaw.us/code/355d549b-c6e6-4f10-bd69-fded388da43c
Sec. 18-290. - Plank subfloor.
Plank subflooring shall comply with the following specifications: (1) Planks shall be T and G or splined; minimum thickness, two inches; maximum width, eight inches. Square edge planks may be used where strip flooring with T and G edges is installed at right angles to plank or where a separate underlayment is provided. (2) Where practicable, planks shall be continuous over at least two spans. All joints shall be cut parallel to and over center of floor beams with not more than two adjacent planks breaking joints over the same support except at ends and at openings. (3) Maximum span of two-inch plank deck shall not exceed the following: a. Planks continuous over two spans, seven feet. b. Planks over single span only, five feet. c. Other spans may be used when calculated according to standard engineering practices. Deflection shall be limited to 1/360 of span. (4) Plank deck shall be blind and face nailed to floor beams in accordance with the nailing schedule, Table No. 4, section 18-442. (5) Loads from bearing partitions, interior columns, or other concentrated loads shall be supported independent from plank deck.
(Code 1973, § 30.32.050)
Ask a question about Racine law
Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.