Sec. 18-288. - Plywood.

Plywood used as structural subflooring shall be applied continuously over two or more spans with the direction of the face grain perpendicular to supports. The allowable spans shall comply with those given in Table F. _____ TABLE F Allowable spans for plywood floor and roof sheathing continuous over two or more spans and face grain perpendicular to supports (span in inches). 1 Roof | Floor Maximum span (inches) | Load (psf) Panel identification index 2 Roof span, roof/floor span | Thickness (inches) | Edges blocked 3 | Edges unblocked | Total load | Live load | Maximum span 5 (inches) 12/00 | 5/16 | 12 | 12 | 155 | 150 | 0 16/00 | 5/16 , ⅜ | 16 | 16 | 95 | 75 | 0 20/00 | 5/16 , ⅜ | 20 | 20 | 75 | 65 | 0 24/00 | ⅜ | 24 | 24 | 65 | 50 | 0 24/00 | ½ | 24 | 24 | 65 | 50 | 0 30/12 | ⅝ | 30 | 26 | 70 | 50 | 12 6 32/16 | ½, ⅝ | 32 | 28 | 55 | 40 | 16 7 36/16 | ¾ | 36 | 30 | 55 | 50 | 16 7 42/20 | ⅝, ¾, ⅞ | 42 | 32 | 40 4 | 35 4 | 20 7, 8 48/24 | ¾, ⅞ | 48 | 36 | 40 4 | 35 4 | 24 Notes: 1. These values apply to C-D, C-C, structural I and II grades only. Spans shall be limited to values shown because of possible effect of concentrated loads. 2. Identification index appears on all panels in the construction grades listed in footnote (1). 3. Edges may be blocked with lumber or other approved type of edge support. 4. For roof live load of 40 psf or total load of 55 psf, decrease spans by 13 percent or use panel with next greater identification index. 5. Plywood edges shall have approved tongue-and-groove (T and G) joints or shall be supported with blocking, unless one-fourth-inch minimum thickness underlayment is installed, or finish floor is 25/32 -inch wood strip. Allowable uniform load based on deflections of 1/360 of space is 165 psf. 6. May be 16 inches, if 25/32 -inch wood strip flooring is installed at right angles to joists. 7. May be 24 inches if 25/32 -inch wood strip flooring is installed at right angles to joists. 8. Plywood sheathing with identification index numbers 42/20 or greater can be used for subfloors when supporting 1½ inches of lightweight concrete over joists spaced 24 inches on center. _____

(Code 1973, § 30.32.030)

Ask a question about Racine law

Corpus searches the Racine sections it holds and shows the ones that match, with their citations. Free, no sign-in.